40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.1.1.2.4 Method of test
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.1.1.2.4.1 Initial conditions
Test environment: normal, TL/VL, TL/VH, TH/VL, TH/VH; see clauses G.2.1 and G.2.2. Frequencies to be tested: mid range; see clause G.2.4. In this case all cells are on the same frequency. Cell 1 and cell 2 shall be synchronised, i.e. share the same frame and timeslot timing. The DL DPCH shall be transmitted in timeslot 4 and the UL DPCH shall be transmitted in timeslot 12. The second Beacon timeslot shall be provided in timeslot 8 for both cell 1 and cell 2. P-CCPCH RSCP intra frequency relative accuracy requirements are tested by using test parameters in table 8.7.1.1.1.2. 1) A call is set up according to the test procedure specified in TS 34.108 [3] clause 7.3.2.3. The RF parameters for Test 1 are set up according to table 8.7.1.1.1.2.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.1.1.2.4.2 Procedure
1) SS shall transmit MEASUREMENT CONTROL message. 2) UE shall transmit periodically MEASUREMENT REPORT messages. 3) SS shall check PCCPCH_RSCP value of Cell 1 and Cell 2 in MEASUREMENT REPORT messages. PCCPCH RSCP power value measured from Cell 1 is compared to PCCPCH RSCP power value measured from Cell 2 for each MEASUREMENT REPORT message. 4) The result of step 3) is compared to actual power level difference of PCCPCH RSCP of Cell 1 and Cell 2. 5) SS shall count number of MEASUREMENT REPORT messages transmitted by UE. After 1000 MEASUREMENT REPORT messages have been received from UE, the RF parameters are set up according to table 8.7.1.1.1.2 for Test 2. While RF parameters are being set up, MEASUREMENT REPORT messages from UE are ignored. SS shall wait for additional 1s and ignore the MEASUREMENT REPORT messages during this period. Then, steps 3) and 4) above are repeated. After further 1000 MEASUREMENT REPORT messages have been received from UE, the RF parameters are set up according to table 8.7.1.1.1.2 for Test 3. While RF parameters are being set up, MEASUREMENT REPORT messages from UE are ignored. SS shall wait for additional 1s and ignore the MEASUREMENT REPORT messages during this period. Then, steps 3) and 4) above are repeated. 6) After further 1000 MEASUREMENT REPORT messages have been received from UE, the SS shall transmit RRC CONNECTION RELEASE message. 7) UE shall transmit RRC CONNECTION RELEASE COMPLETE message. Specific Message Contents All messages indicated above shall use the same content as described in the default message content in clause 9 of 34.108 [3] and in Annex I, with the following exceptions: MEASUREMENT CONTROL message for intra frequency measurement in clause 8.7.1.1.1.4.2 shall be used.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.1.1.2.5 Test requirements
The PCCPCH RSCP measurement accuracy shall meet the requirements in clause 8.7.1.1.2.2 for at least 900 of the measurement reports at each input level in step 4. NOTE: If the above Test Requirement differs from the Minimum Requirement then the Test Tolerance applied for this test is non-zero. The Test Tolerance for this test is defined in clause F.2 and the explanation of how the Minimum Requirement has been relaxed by the Test Tolerance is given in clause F.4. 8.7.1.1A Intra frequency measurement accuracy for 1,28 Mcps TDD Option 8.7.1.1A.1 Absolute accuracy requirement 8.7.1.1A.1.1 Definition and applicability The absolute accuracy of P-CCPCH RSCP is defined as the P-CCPCH RSCP measured from one cell compared to the actual P-CCPCH RSCP power from the same cell. The requirements and this test apply to all types of UTRA TDD UE 1,28 Mcps option. 8.7.1.1A.1.2 Minimum Requirements The absolute accuracy requirements in table 8.7.1.1A.1.1 are valid under the following conditions: P-CCPCH RSCP  -102 dBm. Table 8.7.1.1A.1.1: P-CCPCH_RSCP absolute accuracy Parameter Unit Accuracy [dB] Conditions Normal condition Extreme condition Io [dBm/1.28MHz] P-CCPCH_RSCP dBm  6  9 -94...-70 dBm  8  11 -70...-50 The rate of correct measurements observed during repeated tests shall be at least 90%. The normative reference for this requirement is TS 25.123 [2] clauses 9.1.1.1.1 and A.9.2.1.1.1. 8.7.1.1A.1.3 Test Purpose The purpose of this test is to verify that the absolute P-CCPCH RSCP measurement accuracy is within the specified limits. 8.7.1.1A.1.4 Method of test 8.7.1.1A.1.4.1 Initial conditions Test environment: normal, TL/VL, TL/VH, TH/VL, TH/VH; see clauses G.2.1 and G.2.2. Frequencies to be tested: mid range; see clause G.2.4. In this case all cells are on the same frequency. Cell 1 and cell 2 shall be synchronised, i.e. share the same frame and timeslot timing. The DL DPCH shall be transmitted in timeslot 5 and the UL DPCH shall be transmitted in timeslot 2. P-CCPCH RSCP intra frequency absolute accuracy requirements are tested by using test parameters in table 8.7.1.1A.1.2. Table 8.7.1.1A.1.2: P-CCPCH RSCP Intra frequency test parameters Test 1 Parameter Unit Cell 1 Cell 2 Timeslot Number 0 DwPTS 0 DwPTS UTRA RF Channel Number Channel 1 Channel 1 PCCPCH_Ec/Ior dB -3 -3 DwPCH_Ec/Ior dB 0 0 OCNS_Ec/Ior dB -3 -3 dB 5 2 dBm/ 1,28 MHz -76.6 PCCPCH RSCP, Note 1 dBm -74.6 -77.6 Io, Note 1 dBm/ 1,28 MHz -69 Propagation condition AWGN Test 2 Parameter Unit Cell 1 Cell 2 Timeslot Number 0 DwPTS 0 DwPTS UTRA RF Channel Number Channel 1 Channel 1 PCCPCH_Ec/Ior dB -3 -3 DwPCH_Ec/Ior dB 0 0 OCNS_Ec/Ior dB -3 -3 dB 9 2 dBm/ 1,28 MHz -60.2 PCCPCH RSCP, Note 1 dBm -54.2 -61.2 Io, Note 1 dBm/ 1,28 MHz -50 Propagation condition AWGN Test 3 Parameter Unit Cell 1 Cell 2 Timeslot Number 0 DwPTS 0 DwPTS UTRA RF Channel Number Channel 1 Channel 1 PCCPCH_Ec/Ior dB -3 -3 DwPCH_Ec/Ior dB 0 0 OCNS_Ec/Ior dB -3 -3 dB 5 3 dBm/ 1,28 MHz -101.9 PCCPCH RSCP, Note 1 dBm -99.9 -101.9 Io, Note 1 dBm/ 1,28 MHz -94 Propagation condition AWGN NOTE 1: PCCPCH RSCP and Io levels have been calculated from other parameters for information purposes. They are not settable parameters themselves. 1) A call is set up according to the test procedure specified in TS 34.108 [3] clause 7.3.2.3. The RF parameters for Test 1 are set up according to table 8.7.1.1A.1.2. 8.7.1.1A.1.4.2 Procedure 1) SS shall transmit MEASUREMENT CONTROL message. 2) UE shall transmit periodically MEASUREMENT REPORT messages. 3) SS shall check PCCPCH_RSCP value in MEASUREMENT REPORT messages. PCCPCH_RSCP power of Cell 1 reported by UE is compared to actual PCCPCH_RSCP power for each MEASUREMENT REPORT message. 4) SS shall count number of MEASUREMENT REPORT messages transmitted by UE. After 1000 MEASUREMENT REPORT messages have been received from UE, the RF parameters are set up according to table 8.7.1.1A.1.2 for Test 2. While RF parameters are being set up, MEASUREMENT REPORT messages from UE are ignored. SS shall wait for additional 1s and ignore the MEASUREMENT REPORT messages during this period. Then, step 3) above is repeated. After further 1000 MEASUREMENT REPORT messages have been received from UE, the RF parameters are set up according to table 8.7.1.1A.1.2 for Test 3. While RF parameters are being set up, MEASUREMENT REPORT messages from UE are ignored. SS shall wait for additional 1s and ignore the MEASUREMENT REPORT messages during this period. Then, step 3) above is repeated. 5) After further 1000 MEASUREMENT REPORT messages have been received from UE, the SS shall transmit RRC CONNECTION RELEASE message. 6) UE shall transmit RRC CONNECTION RELEASE COMPLETE message. Specific Message Contents All messages indicated above shall use the same content as described in the default message content in clause 9 of 34.108 [3] and in Annex I, with the following exceptions: MEASUREMENT CONTROL message (Step 1): Information Element/Group name Value/Remark Message Type (10.2.17) UE information elements -RRC transaction identifier 0 -Integrity check info Not Present Measurement Information elements -Measurement Identity 1 -Measurement Command (10.3.7.46) setup -Measurement Reporting Mode (10.3.7.49) -Measurement Report Transfer Mode AM RLC -Periodical Reporting / Event Trigger Reporting Mode Periodical reporting -Additional measurements list (10.3.7.1) Not Present -CHOICE Measurement type Intra-frequency measurement -Intra-frequency measurement (10.3.7.36) -Intra-frequency measurement objects list (10.3.7.33) Not Present -Intra-frequency measurement quantity (10.3.7.38) -Filter coefficient (10.3.7.9) 0 -CHOICE mode TDD -Measurement quantity list 1 -Measurement quantity Primary CCPCH RSCP -Intra-frequency reporting quantity (10.3.7.41) -Reporting quantities for active set cells (10.3.7.5) -SFN-SFN observed time difference reporting indicator No report -Cell synchronisation information reporting indicator FALSE -Cell Identity reporting indicator TRUE -CHOICE mode TDD -Timeslot ISCP reporting indicator FALSE -Primary CCPCH RSCP reporting indicator TRUE -Pathloss reporting indicator FALSE -Reporting quantities for monitored set cells (10.3.7.5) -SFN-SFN observed time difference reporting indicator No report -Cell synchronisation information reporting indicator FALSE -Cell Identity reporting indicator TRUE -CHOICE mode TDD -Timeslot ISCP reporting indicator FALSE -Proposed TGSN reporting required FALSE -Primary CCPCH RSCP reporting indicator TRUE -Pathloss reporting indicator FALSE -Reporting quantities for detected set cells (10.3.7.5) Not Present -Reporting cell status (10.3.7.61) -CHOICE reported cell Report all active set cells + cells within monitored set on used frequency -Maximum number of reported cells 1 -Measurement validity (10.3.7.51) Not Present -CHOICE report criteria (10.3.7. -Periodical reporting criteria (10.3.7.53) -Amount of reporting Infinity -Reporting interval 250 ms Physical channel information elements -DPCH compressed mode status info (10.3.6.34) Not Present 8.7.1.1A.1.5 Test requirements The PCCPCH RSCP measurement accuracy shall meet the requirements in clause 8.7.1.1A.1.2 for at least 900 of the measurement reports at each input level in step 4. NOTE: If the above Test Requirement differs from the Minimum Requirement then the Test Tolerance applied for this test is non-zero. The Test Tolerance for this test is defined in clause F.2 and the explanation of how the Minimum Requirement has been relaxed by the Test Tolerance is given in clause F.4. 8.7.1.1A.2 Relative accuracy requirement 8.7.1.1A.2.1 Definition and applicability The relative accuracy of PCCPCH RSCP is defined as the PCCPCH RSCP measured from one cell compared to the PCCPCH RSCP measured from another cell on the same frequency. The requirements and this test apply to all types of UTRA TDD UE 1,28 Mcps option. 8.7.1.1A.2.2 Minimum Requirements The relative accuracy requirements in table 8.7.1.1A.2.1 are valid under the following conditions: P-CCPCH RSCP  -102 dBm. It is assumed that the measurements of P-CCPCH RSCP1 and P-CCPCH RSCP2 can be performed within 20ms due to slot allocations in the cells concerned. Table 8.7.1.1A.2.1: P-CCPCH_RSCP intra-frequency relative accuracy Parameter Unit Accuracy [dB] Conditions Normal condition Extreme condition Io [dBm /1.28 MHz] P-CCPCH_RSCP dBm 3 3 -94...-50 The normative reference for this requirement is TS 25.123 [2] clauses 9.1.1.1.2 and A.9.2.1.1.1. 8.7.1.1A.2.3 Test Purpose The purpose of this test is to verify that the relative P-CCPCH RSCP measurement accuracy is within the specified limits. 8.7.1.1A.2.4 Method of test 8.7.1.1A.2.4.1 Initial conditions Test environment: normal, TL/VL, TL/VH, TH/VL, TH/VH; see clauses G.2.1 and G.2.2. Frequencies to be tested: mid range; see clause G.2.4. In this case all cells are on the same frequency. Cell 1 and cell 2 shall be synchronised, i.e. share the same frame and timeslot timing. The DL DPCH shall be transmitted in timeslot 5 and the UL DPCH shall be transmitted in timeslot 2. P-CCPCH RSCP intra frequency relative accuracy requirements are tested by using test parameters in table 8.7.1.1A.1.2. 1) A call is set up according to the test procedure specified in TS 34.108 [3] clause 7.3.2.3. The RF parameters for Test 1 are set up according to table 8.7.1.1A.1.2. 8.7.1.1A.2.4.2 Procedure 1) SS shall transmit MEASUREMENT CONTROL message. 2) UE shall transmit periodically MEASUREMENT REPORT messages. 3) SS shall check PCCPCH_RSCP value of Cell 1 and Cell 2 in MEASUREMENT REPORT messages. PCCPCH RSCP power value measured from Cell 1 is compared to PCCPCH RSCP power value measured from Cell 2 for each MEASUREMENT REPORT message. 4) The result of step 3) is compared to actual power level difference of PCCPCH RSCP of Cell 1 and Cell 2. 5) SS shall count number of MEASUREMENT REPORT messages transmitted by UE. After 1000 MEASUREMENT REPORT messages have been received from UE, the RF parameters are set up according to table 8.7.1.1A.1.2 for Test 2. While RF parameters are being set up, MEASUREMENT REPORT messages from UE are ignored. SS shall wait for additional 1s and ignore the MEASUREMENT REPORT messages during this period. Then, steps 3) and 4) above are repeated. After further 1000 MEASUREMENT REPORT messages have been received from UE, the RF parameters are set up according to table 8.7.1.1A.1.2 for Test 3. While RF parameters are being set up, MEASUREMENT REPORT messages from UE are ignored. SS shall wait for additional 1s and ignore the MEASUREMENT REPORT messages during this period. Then, steps 3) and 4) above are repeated. 6) After further 1000 MEASUREMENT REPORT messages have been received from UE, the SS shall transmit RRC CONNECTION RELEASE message. 7) UE shall transmit RRC CONNECTION RELEASE COMPLETE message. Specific Message Contents All messages indicated above shall use the same content as described in the default message content in clause 9 of 34.108 [3] and in Annex I, with the following exceptions: MEASUREMENT CONTROL message for intra frequency measurement in clause 8.7.1.1A.1.4.2 shall be used. 8.7.1.1A.2.5 Test requirements The PCCPCH RSCP measurement accuracy shall meet the requirements in clause 8.7.1.1A.2.2 for at least 900 of the measurement reports at each input level in step 4. NOTE: If the above Test Requirement differs from the Minimum Requirement then the Test Tolerance applied for this test is non-zero. The Test Tolerance for this test is defined in clause F.2 and the explanation of how the Minimum Requirement has been relaxed by the Test Tolerance is given in clause F.4. 8.7.1.1A.3 Absolute accuracy requirement with two neighbouring cells 8.7.1.1A.3.1 Definition and applicability The absolute accuracy of P-CCPCH RSCP is defined as the P-CCPCH RSCP measured from one cell compared to the actual P-CCPCH RSCP power from the same cell. 8.7.1.1A.3.2 Minimum Requirements In each case, at least 900 of the 1000 measurement reports must meet the requirements. 8.7.1.1A.3.3 Test purpose The purpose of the test is to verify that in multi-cell environment with frequency offset, phase offset, and inter-cell delay, the P-CCPCH RSCP absolute accuracy of all cells measured by the UE meets the requirements of the specifications. In this way, the multi-cell detection performance of the UE can be checked. 8.7.1.1A.3.4 Method of test 8.7.1.1A.3.4.1 Initial conditions Test environment: normal; see clauses G.2.1 and G.2.2. Frequencies to be tested: mid range; see clause G.2.4. Cell condition: Three 1.28Mcps TDD intra-frequency cells are configured. Signal propagation condition: AWGN P-CCPCH RSCP –102 dBm. Table 8.7.1.1A.3.1: P-CCPCH RSCP Intra-frequency test parameters Test 1 Parameter Unit Cell 1 Cell 2 Cell 3 Timeslot Number 0 DwPTS 0 DwPTS 0 DwPTS UTRA RF Channel Number Channel 1 Channel 1 Channel 1 PCCPCH_Ec/Ior dB –3 –3 –3 DwPCH_Ec/Ior dB 0 0 0 OCNS_Ec/Ior dB –3 –3 –3 dB 9 3 1 dBm/1.28 MHz –79.5 PCCPCH RSCP (Note 1) dBm –73.5 –79.5 –81.5 Io (Note 1) dBm/1.28 MHz –69 Initial Time Delay () (Note 2) Chip 1 5 7 Initial Frequency Shift () (Note 3) Hz 20 40 –40 Initial Phase () (Note 4) Degree 0 Propagation condition AWGN Test 2 Parameter Unit Cell 1 Cell 2 Cell 3 Timeslot Number 0 DwPTS 0 DwPTS 0 DwPTS UTRA RF Channel Number Channel 1 Channel 1 Channel 1 PCCPCH_Ec/Ior dB –3 –3 –3 DwPCH_Ec/Ior dB 0 0 0 OCNS_Ec/Ior dB –3 –3 –3 dB 7 7 1 dBm/1.28 MHz –60.5 PCCPCH RSCP (Note 1) dBm –56.5 –56.5 –62.5 Io (Note 1) dBm/1.28 MHz –50 Initial Time Delay () (Note 2) Chip 1 5 7 Initial Frequency Shift () (Note 3) Hz 20 40 –40 Initial Phase () (Note 4) Degree 0 Propagation condition AWGN Test 3 Parameter Unit Cell 1 Cell 2 Cell 3 Timeslot Number 0 DwPTS 0 DwPTS 0 DwPTS UTRA RF Channel Number Channel 1 Channel 1 Channel 1 PCCPCH_Ec/Ior dB –3 –3 –3 DwPCH_Ec/Ior dB 0 0 0 OCNS_Ec/Ior dB –3 –3 –3 dB 3 3 3 dBm/1.28 MHz –101.8 PCCPCH RSCP (Note 1) dBm –101.8 –101.8 –101.8 Io (Note 1) dBm/1.28 MHz –94 Initial Time Delay () (Note 2) Chip 1 5 7 Initial Frequency Shift () (Note 3) Hz 20 40 –40 Initial Phase () (Note 4) Degree 0 Propagation condition AWGN Note 1: PCCPCH RSCP and Io levels are calculated from other parameters for information purposes. Note 2: The delay of each base station () is moving between [0chips, 2chips] around the base point, that is, the initial cell delay (). The delay variation interval is . is the current subframe delay. The definition is as follows: Here, is the difference between the current subframe and initial subframe in the cell. Note 3: Frequency offset () is the difference between the actual transmit frequency and the nominal frequency in the cell. is the frequency offset of the initial subframe, is the frequency offset of the current subframe, and is the frequency offset of the next subframe. The frequency offset variation interval is . The definition is as follows: Here, is the difference between the current subframe and initial subframe in the cell. Note 4: The cell phase () is changing continuously in the range of . is the initial phase of the cell, is the current subframe cell phase, and the phase variation interval is . The definition is as follows: Here, is the difference between the current subframe and initial subframe in the cell. MEASUREMENT CONTROL message in P-CCPCH RSCP absolute accuracy measurement (step 1) Information Element/Group Name Value/Remark Message Type (10.2.17) UE information elements -RRC transaction identifier 0 -Integrity check info Not Present Measurement Information elements -Measurement Identity 1 -Measurement Command (10.3.7.46) setup -Measurement Reporting Mode (10.3.7.49) -Measurement Report Transfer Mode AM RLC -Periodical Reporting/Event Trigger Reporting Mode Periodical reporting -Additional measurements list (10.3.7.1) Not Present -CHOICE Measurement type Intra-frequency measurement -Intra-frequency measurement (10.3.7.36) -Intra-frequency measurement objects list (10.3.7.33) Not Present -Intra-frequency measurement quantity (10.3.7.38) -Filter coefficient (10.3.7.9) 0 -CHOICE mode TDD -Measurement quantity list 1 -Measurement quantity Primary CCPCH RSCP -Intra-frequency reporting quantity (10.3.7.41) -Reporting quantities for active set cells (10.3.7.5) -SFN-SFN observed time difference reporting indicator No report -Cell synchronization information reporting indicator FALSE -Cell Identity reporting indicator TRUE -CHOICE mode TDD -Timeslot ISCP reporting indicator FALSE -Primary CCPCH RSCP reporting indicator TRUE -Pathloss reporting indicator FALSE -Reporting quantities for monitored set cells (10.3.7.5) -SFN-SFN observed time difference reporting indicator No report -Cell synchronization information reporting indicator FALSE -Cell Identity reporting indicator TRUE -CHOICE mode TDD -Timeslot ISCP reporting indicator FALSE -Proposed TGSN reporting required FALSE -Primary CCPCH RSCP reporting indicator TRUE -Pathloss reporting indicator FALSE -Reporting quantities for detected set cells (10.3.7.5) Not Present -Reporting cell status (10.3.7.61) -CHOICE reported cell Report all active set cells + cells within monitored set on used frequency -Maximum number of reported cells 2 -Measurement validity (10.3.7.51) Not Present -CHOICE report criteria (10.3.7. -Periodical reporting criteria (10.3.7.53) -Amount of reporting Infinity -Reporting interval 250 ms Physical channel information elements -DPCH compressed mode status info (10.3.6.34) Not Present 8.7.1.1A.3.4.2 Procedure 1) A call is set up according to the test procedure specified in 3GPP TS 34.108 sub-clause 7.3.2.3. 2) The RF parameters for Test 1 are set up according to table1. 3) SS shall transmit MEASUREMENT CONTROL message. 4) UE shall transmit periodically MEASUREMENT REPORT messages. 5) SS shall check PCCPCH_RSCP value in MEASUREMENT REPORT messages. PCCPCH_RSCP power of Cell 1, Cell 2, and Cell 3 reported by UE is compared to actual PCCPCH_RSCP power for each MEASUREMENT REPORT message. 6) SS shall count number of MEASUREMENT REPORT messages transmitted by UE. After 1000 MEASUREMENT REPORT messages have been received from UE, the RF parameters are set up according to table1 for Test 2. While RF parameters are set up, MEASUREMENT REPORT messages from UE are ignored. SS shall wait for additional 1s and ignore the MEASUREMENT REPORT messages during this period. Then, repeat steps 3 and 4. After further 1000 MEASUREMENT REPORT messages have been received from UE, the RF parameters are set up according to table1 for Test 3. While RF parameters are set up, MEASUREMENT REPORT messages from UE are ignored. SS shall wait for additional 1s and ignore the MEASUREMENT REPORT messages during this period. Then, repeat steps 3 and 4. 7) After further 1000 MEASUREMENT REPORT messages have been received from UE, the SS shall transmit RRC CONNECTION RELEASE message. 8) UE shall transmit RRC CONNECTION RELEASE COMPLETE message. 8.7.1.1A.3.5 Test requirements P-CCPCH_RSCP intra-frequency measurement accuracy Parameter Unit Accuracy [dB] Conditions Normal condition Extreme condition Io [dBm/ 1.28 MHz] P-CCPCH_RSCP dBm  6  9 -94...-70 dBm  8  11 -70...-50 In each case, at least 900 of the 1000 measurement reports must meet the requirements. 8.7.1.1B Intra frequency measurement accuracy for 7,68 Mcps TDD Option 8.7.1.1B.1 Absolute accuracy requirement 8.7.1.1B.1.1 Definition and applicability The absolute accuracy of P-CCPCH RSCP is defined as the P-CCPCH RSCP meaasured from one cell compared to the actual P-CCPCH RSCP power from the same cell. The requirements and this test apply to all types of UTRA TDD UE. 8.7.1.1B.1.2 Minimum Requirements The absolute accuracy requirements in table 8.7.1.1B.1.2.1 are valid under the following conditions: P-CCPCH RSCP  -102 dBm. Table 8.7.1.1B.1.2.1: P-CCPCH_RSCP absolute accuracy Parameter Unit Accuracy [dB] Conditions Normal condition Extreme condition Io [dBm/3.84MHz] P-CCPCH_RSCP dBm  6  9 -94...-70 dBm  8  11 -70...-50 The normative reference for this requirement is TS 25.123 [2] clauses 9.1.1.1.1.3 and A.9.3.1.1.1. 8.7.1.1B.1.3 Test Purpose The purpose of this test is to verify that the absolute P-CCPCH RSCP measurement accuracy is within the specified limits. 8.7.1.1B.1.4 Method of test 8.7.1.1B.1.4.1 Initial conditions Test environment: normal, TL/VL, TL/VH, TH/VL, TH/VH; see clauses G.2.1 and G.2.2. Frequencies to be tested: mid range; see clause G.2.4. In this case all cells are on the same frequency. Cell 1 and cell 2 shall be synchronised, i.e. share the same frame and timeslot timing. The DL DPCH shall be transmitted in timeslot 4 and the UL DPCH shall be transmitted in timeslot 12. The second Beacon timeslot shall be provided in timeslot 8 for both cell 1 and cell 2. P-CCPCH RSCP intra frequency absolute accuracy requirements are tested by using test parameters in table 8.7.1.1B.1.4.1.1. Table 8.7.1.1B.1.4.1.1: P-CCPCH RSCP intra frequency test parameters Parameter Unit Test 1 Test 2 Test 3 Cell 1 Cell 2 Cell 1 Cell 2 Cell 1 Cell 2 DL timeslot number 0 0 0 0 0 0 UTRA RF Channel number Channel 1 Channel 1 Channel 1 PCCPCH_Ec/Ior dB -3 -3 -3 SCH_Ec/Ior dB -9 -9 -9 SCH_toffset 0 5 0 5 0 5 OCNS_Ec/Ior dB -3,12 -3,12 -3,12 Ioc dBm / 7.68 MHz -75.7 -59.8 -98.7 Îor/Ioc dB 5 2 9 2 3 0 PCCPCH RSCP, Note 1 dBm -73.7 -76.7 -53.8 -60.8 -98.7 -101.7 Io, Note 1 dBm / 7.68 MHz -69 -50 -94 Propagation condition AWGN AWGN AWGN NOTE 1: PCCPCH RSCP and Io levels have been calculated from other parameters for information purposes. They are not settable parameters themselves. 1) A call is set up according to the test procedure specified in TS 34.108 [3] clause 7.3.2.3. The RF parameters for Test 1 are set up according to table 8.7.1.1B.1.4.1.1. 8.7.1.1B.1.4.2 Procedure 1) SS shall transmit MEASUREMENT CONTROL message. 2) UE shall transmit periodically MEASUREMENT REPORT messages. 3) SS shall check PCCPCH_RSCP value in MEASUREMENT REPORT messages. PCCPCH_RSCP power of Cell 1 reported by UE is compared to actual PCCPCH_RSCP power for each MEASUREMENT REPORT message. 4) SS shall count number of MEASUREMENT REPORT messages transmitted by UE. After 1000 MEASUREMENT REPORT messages have been received from UE, the RF parameters are set up according to table 8.7.1.1.1.2 for Test 2. While RF parameters are being set up, MEASUREMENT REPORT messages from UE are ignored. SS shall wait for additional 1s and ignore the MEASUREMENT REPORT messages during this period. Then, steps 2) and 3) above are repeated. After further 1000 MEASUREMENT REPORT messages have been received from UE, the RF parameters are set up according to table 8.7.1.1.1.2 for Test 3. While RF parameters are being set up, MEASUREMENT REPORT messages from UE are ignored. SS shall wait for additional 1s and ignore the MEASUREMENT REPORT messages during this period. Then, steps 2) and 3) above are repeated. 5) After further 1000 MEASUREMENT REPORT messages have been received from UE, the SS shall transmit RRC CONNECTION RELEASE message. 6) UE shall transmit RRC CONNECTION RELEASE COMPLETE message. Specific Message Contents All messages indicated above shall use the same content as described in the default message content in clause 9 of 34.108 [3] and in Annex I, with the following exceptions: MEASUREMENT CONTROL message (Step 1): Information Element/Group name Value/Remark Message Type (10.2.17) UE information elements -RRC transaction identifier 0 -Integrity check info Not Present Measurement Information elements -Measurement Identity 1 -Measurement Command (10.3.7.46) Modify -Measurement Reporting Mode (10.3.7.49) -Measurement Report Transfer Mode AM RLC -Periodical Reporting / Event Trigger Reporting Mode Periodical reporting -Additional measurements list (10.3.7.1) Not Present -CHOICE Measurement type Intra-frequency measurement -Intra-frequency measurement (10.3.7.36) -Intra-frequency measurement objects list (10.3.7.33) Not Present -Intra-frequency measurement quantity (10.3.7.38) -Filter coefficient (10.3.7.9) 0 -CHOICE mode TDD -Measurement quantity list 1 -Measurement quantity Primary CCPCH RSCP -Intra-frequency reporting quantity (10.3.7.41) -Reporting quantities for active set cells (10.3.7.5) -SFN-SFN observed time difference reporting indicator No report -Cell synchronisation information reporting indicator FALSE -Cell Identity reporting indicator TRUE -CHOICE mode TDD -Timeslot ISCP reporting indicator FALSE -Primary CCPCH RSCP reporting indicator TRUE -Pathloss reporting indicator FALSE -Reporting quantities for monitored set cells (10.3.7.5) -SFN-SFN observed time difference reporting indicator No report -Cell synchronisation information reporting indicator FALSE -Cell Identity reporting indicator TRUE -CHOICE mode TDD -Timeslot ISCP reporting indicator FALSE -Proposed TGSN reporting required FALSE -Primary CCPCH RSCP reporting indicator TRUE -Pathloss reporting indicator FALSE -Reporting quantities for detected set cells (10.3.7.5) Not Present -Reporting cell status (10.3.7.61) -CHOICE reported cell Report all active set cells + cells within monitored set on used frequency -Maximum number of reported cells 1 -Measurement validity (10.3.7.51) Not Present -CHOICE report criteria -Periodical reporting criteria (10.3.7.53) -Amount of reporting Infinity -Reporting interval 250 ms Physical channel information elements -DPCH compressed mode status info (10.3.6.34) Not Present 8.7.1.1B.1.5 Test requirements The PCCPCH RSCP measurement accuracy shall meet the requirements in clause 8.7.1.1B.1.2 for at least 900 of the measurement reports at each input level in step 4. NOTE: If the above Test Requirement differs from the Minimum Requirement then the Test Tolerance applied for this test is non-zero. The Test Tolerance for this test is defined in clause F.2 and the explanation of how the Minimum Requirement has been relaxed by the Test Tolerance is given in clause F.4. 8.7.1.1B.2 Relative accuracy requirement 8.7.1.1B.2.1 Definition and applicability The relative accuracy of PCCPCH RSCP is defined as the PCCPCH RSCP measured from one cell compared to the PCCPCH RSCP measured from another cell on the same frequency. The requirements and this test apply to all types of UTRA TDD UE. 8.7.1.1B.2.2 Minimum Requirements The relative accuracy requirements in table 8.7.1.1B.2.2.1 are valid under the following conditions: P-CCPCH RSCP  -102 dBm. Relative Io difference [dB] ≤ relative RSCP difference [dB] It is assumed that the measurements of P-CCPCH RSCP1 and P-CCPCH RSCP2 can be performed within 20ms due to slot allocations in the cells concerned. Table 8.7.1.1B.2.2.1: P-CCPCH_RSCP intra-frequency relative accuracy Parameter Unit Accuracy [dB] Conditions Normal condition Extreme condition Io [dBm/ 7.68MHz] relative RSCP difference [dB] P-CCPCH_RSCP dBm 1 1 -94...-50 <2 2 2 2...14 3  3 >14 The normative reference for this requirement is TS 25.123 [2] clauses 9.1.1.1.2.3 and A.9.3.1.1.1. 8.7.1.1B.2.3 Test Purpose The purpose of this test is to verify that the relative P-CCPCH RSCP measurement accuracy is within the specified limits. 8.7.1.1B.2.4 Method of test 8.7.1.1B.2.4.1 Initial conditions Test environment: normal, TL/VL, TL/VH, TH/VL, TH/VH; see clauses G.2.1 and G.2.2. Frequencies to be tested: mid range; see clause G.2.4. In this case all cells are on the same frequency. Cell 1 and cell 2 shall be synchronised, i.e. share the same frame and timeslot timing. The DL DPCH shall be transmitted in timeslot 4 and the UL DPCH shall be transmitted in timeslot 12. The second Beacon timeslot shall be provided in timeslot 8 for both cell 1 and cell 2. P-CCPCH RSCP intra frequency relative accuracy requirements are tested by using test parameters in table 8.7.1.1B.1.4.1.1. 1) A call is set up according to the test procedure specified in TS 34.108 [3] clause 7.3.2.3. The RF parameters for Test 1 are set up according to table 8.7.1.1.1.2. 8.7.1.1B.2.4.2 Procedure 1) SS shall transmit MEASUREMENT CONTROL message. 2) UE shall transmit periodically MEASUREMENT REPORT messages. 3) SS shall check PCCPCH_RSCP value of Cell 1 and Cell 2 in MEASUREMENT REPORT messages. PCCPCH RSCP power value measured from Cell 1 is compared to PCCPCH RSCP power value measured from Cell 2 for each MEASUREMENT REPORT message. 4) The result of step 3) is compared to actual power level difference of PCCPCH RSCP of Cell 1 and Cell 2. 5) SS shall count number of MEASUREMENT REPORT messages transmitted by UE. After 1000 MEASUREMENT REPORT messages have been received from UE, the RF parameters are set up according to table 8.7.1.1.1.2 for Test 2. While RF parameters are being set up, MEASUREMENT REPORT messages from UE are ignored. SS shall wait for additional 1s and ignore the MEASUREMENT REPORT messages during this period. Then, steps 3) and 4) above are repeated. After further 1000 MEASUREMENT REPORT messages have been received from UE, the RF parameters are set up according to table 8.7.1.1.1.2 for Test 3. While RF parameters are being set up, MEASUREMENT REPORT messages from UE are ignored. SS shall wait for additional 1s and ignore the MEASUREMENT REPORT messages during this period. Then, steps 3) and 4) above are repeated. 6) After further 1000 MEASUREMENT REPORT messages have been received from UE, the SS shall transmit RRC CONNECTION RELEASE message. 7) UE shall transmit RRC CONNECTION RELEASE COMPLETE message. Specific Message Contents All messages indicated above shall use the same content as described in the default message content in clause 9 of 34.108 [3] and in Annex I, with the following exceptions: MEASUREMENT CONTROL message for intra frequency measurement in clause 8.7.1.1B.1.4.2 shall be used. 8.7.1.1B.2.5 Test requirements The PCCPCH RSCP measurement accuracy shall meet the requirements in clause 8.7.1.1B.2.2 for at least 900 of the measurement reports at each input level in step 4. NOTE: If the above Test Requirement differs from the Minimum Requirement then the Test Tolerance applied for this test is non-zero. The Test Tolerance for this test is defined in clause F.2 and the explanation of how the Minimum Requirement has been relaxed by the Test Tolerance is given in clause F.4.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.1.2 Inter frequency measurement accuracy for 3,84 Mcps TDD Option
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.1.2.1 Relative accuracy requirement
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.1.2.1.1 Definition and applicability
The P-CCPCH_RSCP inter-frequency relative accuracy is defined as the P-CCPCH_RSCP measured from one cell compared to the P-CCPCH_RSCP measured from another cell on a different frequency. The requirements and this test apply to all types of UTRA TDD UE.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.1.2.1.2 Minimum Requirements
The relative accuracy requirements in table 8.7.1.2.1.1 are valid under the following conditions: P-CCPCH RSCP  -102 dBm. Table 8.7.1.2.1.1 P-CCPCH_RSCP inter-frequency relative accuracy Parameter Unit Accuracy [dB] Conditions Normal condition Extreme condition Io [dBm/3.84MHz] P-CCPCH_RSCP dBm  6  6 -94...-50 The normative reference for this requirement is TS 25.123 [2] clauses 9.1.1.1.2 and A.9.1.1.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.1.2.1.3 Test Purpose
The purpose of this test is to verify that the relative P-CCPCH RSCP measurement accuracy is within the specified limits for the inter frequency case.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.1.2.1.4 Method of test
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.1.2.1.4.1 Initial conditions
Test environment: normal, TL/VL, TL/VH, TH/VL, TH/VH; see clauses G.2.1 and G.2.2. Frequencies to be tested: mid range; see clause G.2.4. In this case both cells are on different frequencies. The second Beacon timeslot shall be provided in timeslot 8 for cell 1 and in timeslot 10 for cell 2. P-CCPCH RSCP inter frequency relative accuracy requirements are tested by using test parameters in table 8.7.1.2.1.2. Table 8.7.1.2.1.2: P-CCPCH RSCP inter frequency test parameters Parameter Unit Test 1 Test 2 Test 3 Cell 1 Cell 2 Cell 1 Cell 2 Cell 1 Cell 2 DL timeslot number 0 2 0 2 0 2 UTRA RF Channel number Channel 1 Channel 2 Channel 1 Channel 2 Channel 1 Channel 2 PCCPCH_Ec/Ior dB -3 -3 -3 SCH_Ec/Ior dB -9 -9 -9 SCH_toffset 0 5 0 5 0 5 OCNS_Ec/Ior dB -3,12 -3,12 -3,12 Ioc dBm / 3,84 MHz -75.2 -75.2 -57.8 -54.1 -98.7 -97 Îor/Ioc dB 5 5 7 2 3 0 PCCPCH RSCP, Note 1 dBm -73.2 -73.2 -54.8 -55.1 -98.7 -100 Io, Note 1 dBm / 3,84 MHz -69 -50 -94 Propagation condition AWGN AWGN AWGN NOTE 1: PCCPCH RSCP and Io levels have been calculated from other parameters for information purposes. They are not settable parameters themselves. 1) A call is set up according to the test procedure specified in TS 34.108 [3] clause 7.3.2.3. The RF parameters for Test 1 are set up according to table 8.7.1.2.1.2.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.1.2.1.4.2 Procedure
1) SS shall transmit the MEASUREMENT CONTROL messages for intra frequency and inter frequency measurements. 2) UE shall transmit periodically MEASUREMENT REPORT messages. 3) SS shall check PCCPCH_RSCP value of Cell 1 and Cell 2 in MEASUREMENT REPORT messages. PCCPCH RSCP power value measured from Cell 1 is compared to PCCPCH RSCP power value measured from Cell 2 for each MEASUREMENT REPORT message. 4) The result of step 5) is compared to actual power level difference of PCCPCH RSCP of Cell 1 and Cell 2. 5) SS shall count number of MEASUREMENT REPORT messages transmitted by UE. After 1000 MEASUREMENT REPORT messages have been received from UE, the RF parameters are set up according to table 8.7.1.2.1.2 for Test 2. While RF parameters are being set up, MEASUREMENT REPORT messages from UE are ignored. SS shall wait for additional 1s and ignore the MEASUREMENT REPORT messages during this period. Then, steps 3) and 4) above are repeated. 6) After further 1000 MEASUREMENT REPORT messages have been received from UE, the SS shall transmit RRC CONNECTION RELEASE message. 7) UE shall transmit RRC CONNECTION RELEASE COMPLETE message. Specific Message Contents All messages indicated above shall use the same content as described in the default message content in clause 9 of 34.108 [3] and in Annex I, with the following exceptions: First MEASUREMENT CONTROL message for intra frequency measurements (Step 1): Information Element/Group name Value/Remark Message Type (10.2.17) UE information elements -RRC transaction identifier 0 -Integrity check info Not Present Measurement Information elements -Measurement Identity 1 -Measurement Command (10.3.7.46) Modify -Measurement Reporting Mode (10.3.7.49) -Measurement Report Transfer Mode AM RLC -Periodical Reporting / Event Trigger Reporting Mode Periodical reporting -Additional measurements list (10.3.7.1) Not Present -CHOICE Measurement type Intra-frequency measurement -Intra-frequency measurement (10.3.7.36) -Intra-frequency measurement objects list (10.3.7.33) Not Present -Intra-frequency measurement quantity (10.3.7.38) -Filter coefficient (10.3.7.9) 0 -CHOICE mode TDD -Measurement quantity list 1 -Measurement quantity Primary CCPCH RSCP -Intra-frequency reporting quantity (10.3.7.41) -Reporting quantities for active set cells (10.3.7.5) -SFN-SFN observed time difference reporting indicator No report -Cell synchronisation information reporting indicator FALSE -Cell Identity reporting indicator FALSE -CHOICE mode TDD -Timeslot ISCP reporting indicator FALSE -Primary CCPCH RSCP reporting indicator TRUE -Pathloss reporting indicator FALSE -Reporting quantities for monitored set cells (10.3.7.5) -SFN-SFN observed time difference reporting indicator No report -Cell synchronisation information reporting indicator FALSE -Cell Identity reporting indicator FALSE -CHOICE mode TDD -Timeslot ISCP reporting indicator FALSE -Proposed TGSN reporting required FALSE -Primary CCPCH RSCP reporting indicator TRUE -Pathloss reporting indicator FALSE -Reporting quantities for detected set cells (10.3.7.5) Not Present -Reporting cell status (10.3.7.61) -CHOICE reported cell Report all active set cells + cells within monitored set on used frequency -Maximum number of reported cells 1 -Measurement validity (10.3.7.51) Not Present -CHOICE report criteria (10.3.7. -Periodical reporting criteria (10.3.7.53) -Amount of reporting Infinity -Reporting interval 250 ms Physical channel information elements -DPCH compressed mode status info (10.3.6.34) Not Present Second MEASUREMENT CONTROL message for inter frequency measurements (Step 1): Information Element/Group name Value/Remark Message Type (10.2.17) UE information elements -RRC transaction identifier 0 -Integrity check info Not Present Measurement Information elements -Measurement Identity 2 -Measurement Command (10.3.7.46) Setup -Measurement Reporting Mode (10.3.7.49) -Measurement Report Transfer Mode AM RLC -Periodical Reporting / Event Trigger Reporting Mode Periodical reporting -Additional measurements list (10.3.7.1) Not Present -CHOICE Measurement type Inter-frequency measurement -Inter-frequency measurement (10.3.7.16) -Inter-frequency measurement objects list (10.3.7.13) -CHOICE inter-frequency cell removal Not present -New inter-frequency cells Cell 2 information is included -Cell for measurement Not Present -Inter-frequency measurement quantity (10.3.7.18) -CHOICE reporting critera Inter-frequency reporting criteria -Filter coefficient (10.3.7.9) 0 -CHOICE mode TDD -Measurement quantity for frequency quality estimate Primary CCPCH RSCP -Inter-frequency reporting quantity (10.3.7.21) -UTRA carrier RSSI FALSE -Frequency quality estimate TRUE -Non frequency related cell reporting quantities (10.3.7.5) -SFN-SFN observed time difference reporting indicator No report -Cell synchronisation information reporting indicator FALSE -Cell identity reporting indicator FALSE -CHOICE mode TDD -Timeslot ISCP reporting indicator FALSE -Proposed TGSN Reporting required FALSE -Primary CCPCH RSCP reporting indicator TRUE -Pathloss reporting indicator FALSE -Reporting cell status (10.3.7.61) -CHOICE reported cell Report all active set cells + cells within monitored set on used frequency -Maximum number of reported cells Virtual/active set cells + 2 -Measurement validity (10.3.7.51) Not present -Inter-frequency set update Not present -CHOICE report criteria (10.3.7. -Periodical reporting criteria (10.3.7.53) -Amount of reporting Infinity -Reporting interval 500 ms Physical channel information elements -DPCH compressed mode status info (10.3.6.34) Not Present
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.1.2.1.5 Test requirements
The PCCPCH RSCP measurement accuracy shall meet the requirements in clause 8.7.1.2.1.2 for at least 900 of the measurement reports at each input level in step 4. NOTE: If the above Test Requirement differs from the Minimum Requirement then the Test Tolerance applied for this test is non-zero. The Test Tolerance for this test is defined in clause F.2 and the explanation of how the Minimum Requirement has been relaxed by the Test Tolerance is given in clause F.4. 8.7.1.2A Inter frequency measurement accuracy for 1,28 Mcps TDD Option 8.7.1.2A.1 Relative accuracy requirement 8.7.1.2A.1.1 Definition and applicability The P-CCPCH_RSCP inter-frequency relative accuracy is defined as the P-CCPCH_RSCP measured from one cell compared to the P-CCPCH_RSCP measured from another cell on a different frequency. The requirements and this test apply to all types of UTRA TDD UE 1,28 Mcps option. 8.7.1.2A.1.2 Minimum Requirements The relative accuracy requirements in table 8.7.1.2A.1.1 are valid under the following conditions: P-CCPCH RSCP  -102 dBm. Table 8.7.1.2A.1.1 P-CCPCH_RSCP inter-frequency relative accuracy Parameter Unit Accuracy [dB] Conditions Normal condition Extreme condition Io [dBm/1.28MHz] P-CCPCH_RSCP dBm  6  6 -94...-50 The rate of correct measurements observed during repeated tests shall be at least 90%. The normative reference for this requirement is TS 25.123 [2] clauses 9.1.1.1.2 and A.9.2.1. 8.7.1.2A.1.3 Test Purpose The purpose of this test is to verify that the relative P-CCPCH RSCP measurement accuracy is within the specified limits for the inter frequency case. 8.7.1.2A.1.4 Method of test 8.7.1.2A.1.4.1 Initial conditions Test environment: normal, TL/VL, TL/VH, TH/VL, TH/VH; see clauses G.2.1 and G.2.2. Frequencies to be tested: mid range; see clause G.2.4. In this case both cells are on different frequencies. P-CCPCH RSCP inter frequency relative accuracy requirements are tested by using test parameters in table 8.7.1.2A.1.2. Table 8.7.1.2A.1.2: P-CCPCH RSCP Inter frequency test parameters Test 1 Parameter Unit Cell 1 Cell 2 Timeslot Number 0 DwPTS 0 DwPTS UTRA RF Channel Number Channel 1 Channel 2 PCCPCH_Ec/Ior dB -3 -3 DwPCH_Ec/Ior dB 0 0 OCNS_Ec/Ior dB -3 -3 dB 5 5 dBm/ 1,28 MHz -75.2 -75.2 PCCPCH RSCP, Note 1 dBm -73.2 -73.2 Io, Note 1 dBm/ 1,28 MHz -69 Propagation condition AWGN Test 2 Parameter Unit Cell 1 Cell 2 Timeslot Number 0 DwPTS 0 DwPTS UTRA RF Channel Number Channel 1 Channel 2 PCCPCH_Ec/Ior dB -3 -3 DwPCH_Ec/Ior dB 0 0 OCNS_Ec/Ior dB -3 -3 dB 7 2 dBm/ 1,28 MHz -57.8 -54.1 PCCPCH RSCP, Note 1 dBm -53.8 -55.1 Io, Note 1 dBm/ 1,28 MHz -50 Propagation condition AWGN Test 3 Parameter Unit Cell 1 Cell 2 Timeslot Number 0 DwPTS 0 DwPTS UTRA RF Channel Number Channel 1 Channel 2 PCCPCH_Ec/Ior dB -3 -3 DwPCH_Ec/Ior dB 0 0 OCNS_Ec/Ior dB -3 -3 dB 3 0 dBm/ 1,28 MHz -98.7 -97 PCCPCH RSCP, Note 1 dBm -98.7 -100 Io, Note 1 dBm/ 1,28 MHz -94 Propagation condition AWGN NOTE 1: PCCPCH RSCP and Io levels have been calculated from other parameters for information purposes. They are not settable parameters themselves. 1) A call is set up according to the test procedure specified in TS 34.108 [3] clause 7.3.2.3. The RF parameters for Test 1 are set up according to table 8.7.1.2A.1.2. 8.7.1.2A.1.4.2 Procedure 1) SS shall transmit MEASUREMENT CONTROL message. 2) UE shall transmit periodically MEASUREMENT REPORT messages. 3) SS shall check PCCPCH_RSCP value of Cell 1 and Cell 2 in MEASUREMENT REPORT messages. PCCPCH RSCP power value measured from Cell 1 is compared to PCCPCH RSCP power value measured from Cell 2 for each MEASUREMENT REPORT message. 4) The result of step 3) is compared to actual power level difference of PCCPCH RSCP of Cell 1 and Cell 2. 5) SS shall count number of MEASUREMENT REPORT messages transmitted by UE. After 1000 MEASUREMENT REPORT messages have been received from UE, the RF parameters are set up according to table 8.7.1.2A.1.2 for Test 2. While RF parameters are being set up, MEASUREMENT REPORT messages from UE are ignored. SS shall wait for additional 1s and ignore the MEASUREMENT REPORT messages during this period. Then, steps 3) and 4) above are repeated. 6) After further 1000 MEASUREMENT REPORT messages have been received from UE, the SS shall transmit RRC CONNECTION RELEASE message. 7) UE shall transmit RRC CONNECTION RELEASE COMPLETE message. Specific Message Contents All messages indicated above shall use the same content as described in the default message content in clause 9 of 34.108 [3], with the following exceptions: First MEASUREMENT CONTROL message for Intra frequency measurement (Step 1): Information Element Value/Remark Message Type UE information elements -RRC transaction identifier 0 Measurement Information elements -Measurement Identity -Measurement Command -Measurement Reporting Mode - Measurement Report Transfer Mode - Periodical Reporting / Event Trigger Reporting Mode -Additional measurement list -CHOICE Measurement Type -Intra-frequency measurement - Intra-frequency measurement objects list -Intra-frequency cell info list -Intra-frequency measurement quantity -Filter coefficient -CHOICE mode -Measurement quantity -Intra-frequency reporting quantity -Reporting quantities for active set cells -Cell synchronisation information reporting indicator -Cell Identity reporting indicator -CHOICE mode - Timeslot ISCP reporting indicator - Proposed TGSN Reporting required - Primary CCPCH RSCP reporting indicator -Pathloss reporting indicator -Reporting quantities for monitored set cells -Cell synchronisation information reporting indicator -Cell Identity reporting indicator -CHOICE mode - Timeslot ISCP reporting indicator - Proposed TGSN Reporting required PCCPCH RSCP reporting indicator -Pathloss reporting indicator -Reporting quantities for detected set cells -Reporting cell status -CHOICE reported cell -Maximum number of reported cells -Measurement validity -CHOICE report criteria -Amount of reporting -Reporting interval 1 setup Acknowledged mode RLC Periodical reporting Not Present Intra-frequency measurement Not Present 0 TDD PCCPCH RSCP TRUE TRUE TDD FALSE FALSE TRUE FALSE FALSE TRUE FDD FALSE FALSE TRUE FALSE Not Present Report all active set cells + cells within monitored set on used frequency Virtual/active set cells + 2 Not Present Periodical reporting criteria Infinity 250 ms Physical channel information elements -DPCH compressed mode status info Not Present Second MEASUREMENT CONTROL message for Inter frequency measurement (step 1): Information Element Value/Remark Message Type UE information elements -RRC transaction identifier 0 Measurement Information elements -Measurement Identity -Measurement Command -Measurement Reporting Mode - Measurement Report Transfer Mode - Periodical Reporting / Event Trigger Reporting Mode -Additional measurement list -CHOICE Measurement Type -Inter-frequency measurement object list -CHOICE Inter-frequency cell removal -New inter-frequency cells -Cell for measurement -Inter-frequency measurement quantity -CHOICE reporting criteria -Filter coefficient -CHOICE mode -Measurement quantity for frequency quality estimate -Inter-frequency reporting quantity -UTRA Carrier RSSI -Frequency quality estimate -Non frequency related cell reporting quantities -Cell synchronisation information reporting indicator -Cell Identity reporting indicator -CHOICE mode -Timeslot ISCP reporting indicator - Proposed TGSN Reporting required -PCCPCH RSCP reporting indicator -Pathloss reporting indicator -Reporting cell status -CHOICE reported cell -Maximum number of reported cells -Measurement validity -Inter-frequency set update -CHOICE report criteria -Amount of reporting -Reporting interval 2 Setup Acknowledged mode RLC Periodical reporting Not Present Inter-frequency measurement Not Present Cell 2 information is included Not Present Inter-frequency reporting criteria 0 TDD PCCPCH RSCP TRUE TRUE TRUE TRUE FDD FALSE FALSE TRUE FALSE Report cells within monitored set on non-used frequency 2 Not Present Not Present Periodical reporting criteria Infinity 500 ms Physical channel information elements -DPCH compressed mode status info Not Present MEASUREMENT REPORT message for Inter frequency test cases This message is common for all inter frequency test cases in clause 8.7 and is described in Annex I. 8.7.1.2A.1.5 Test requirements The PCCPCH RSCP measurement accuracy shall meet the requirements in clause 8.7.1.2A.1.2 for at least 900 of the measurement reports at each input level in step 4. NOTE: If the above Test Requirement differs from the Minimum Requirement then the Test Tolerance applied for this test is non-zero. The Test Tolerance for this test is defined in clause F.2 and the explanation of how the Minimum Requirement has been relaxed by the Test Tolerance is given in clause F.4. 8.7.1.2A.2 Absolute accuracy requirement 8.7.1.2A.2.1 Definition and applicability The absolute accuracy of P-CCPCH RSCP is defined as the P-CCPCH RSCP measured from one cell compared to the actual P-CCPCH RSCP power from the same cell. The requirements and this test apply to all types of 1.28 Mcps TDD UE. 8.7.1.2A.2.2 Minimum Requirements In each case, at least 900 of the 1000 measurement reports must meet the requirements. 8.7.1.2A.2.3 Test Purpose The purpose of the test is to verify that the absolute accuracy of P-CCPCH RSCP in inter-frequency case meets the requirements of the specifications. 8.7.1.2A.2.4 Method of test 8.7.1.2A.2.4.1 Initial conditions Test environment: normal, TL/VL, TL/VH, TH/VL, TH/VH; see clauses G.2.1 and G.2.2. Frequencies to be tested: mid range; see clause G.2.4. Cell condition: Two 1.28Mcps TDD inter-frequency cells are configured. Signal propagation condition: AWGN Test instrument: AWGN noise source P-CCPCH RSCP –102 dBm. Table 8.7.1.2A.2.1: P-CCPCH RSCP Inter frequency test parameter Test 1 Parameter Unit Cell 1 Cell 2 Timeslot Number 0 DwPTS 0 DwPTS UTRA RF Channel Number Channel 1 Channel 2 PCCPCH_Ec/Ior dB –3 –3 DwPCH_Ec/Ior dB 0 0 OCNS_Ec/Ior dB –3 –3 dB 5 5 dBm/1.28 MHz –75.2 –75.2 PCCPCH RSCP (Note 1) dBm –73.2 –73.2 Io (Note 1) dBm/1.28 MHz –69 Propagation condition AWGN Test 2 Parameter Unit Cell 1 Cell 2 Timeslot Number 0 DwPTS 0 DwPTS UTRA RF Channel Number Channel 1 Channel 2 PCCPCH_Ec/Ior dB –3 –3 DwPCH_Ec/Ior dB 0 0 OCNS_Ec/Ior dB –3 –3 dB 7 2 dBm/1.28 MHz –57.8 –54.1 PCCPCH RSCP (Note 1) dBm –53.8 –55.1 Io (Note 1) dBm/1.28 MHz –50 Propagation condition AWGN Test 3 Parameter Unit Cell 1 Cell 2 Timeslot Number 0 DwPTS 0 DwPTS UTRA RF Channel Number Channel 1 Channel 2 PCCPCH_Ec/Ior dB –3 –3 DwPCH_Ec/Ior dB 0 0 OCNS_Ec/Ior dB –3 –3 dB 3 0 dBm/1.28 MHz –98.7 –97 PCCPCH RSCP (Note 1) dBm –98.7 –100 Io (Note 1) dBm/1.28 MHz –94 Propagation condition AWGN Note 1: PCCPCH RSCP and Io levels are calculated from other parameters for information purposes. 8.7.1.2A.2.4.2 Procedure 1) A call is set up according to the test procedure specified in 3GPP TS 34.108 sub-clause 7.3.2.3. 2) The RF parameters for Test 1 are set up according to table1. 3) SS shall transmit MEASUREMENT CONTROL message. 4) UE shall transmit periodically MEASUREMENT REPORT messages. 5) SS shall check PCCPCH_RSCP value in MEASUREMENT REPORT messages. PCCPCH_RSCP power of Cell 1 and CELL 2 reported by UE is compared to actual PCCPCH_RSCP power for each MEASUREMENT REPORT message. 6) SS shall count number of MEASUREMENT REPORT messages transmitted by UE. After 1000 MEASUREMENT REPORT messages have been received from UE, the RF parameters are set up according to table1 for Test 2. While RF parameters are set up, MEASUREMENT REPORT messages from UE are ignored. SS shall wait for additional 1s and ignore the MEASUREMENT REPORT messages during this period. Then, repeat steps 3 and 4. After further 1000 MEASUREMENT REPORT messages have been received from UE, the RF parameters are set up according to table1 for Test 3. While RF parameters are set up, MEASUREMENT REPORT messages from UE are ignored. SS shall wait for additional 1s and ignore the MEASUREMENT REPORT messages during this period. Then, repeat steps 3 and 4. 7) After further 1000 MEASUREMENT REPORT messages have been received from UE, the SS shall transmit RRC CONNECTION RELEASE message. 8) UE shall transmit RRC CONNECTION RELEASE COMPLETE message. Specific Message Contents All messages indicated above shall use the same content as described in the default message content in clause 9 of 34.108 [3], with the following exceptions: First MEASUREMENT CONTROL message for Intra frequency measurement (step 1) Information Element Value/Remark Message Type UE information elements -RRC transaction identifier 0 Measurement Information elements -Measurement Identity -Measurement Command -Measurement Reporting Mode - Measurement Report Transfer Mode - Periodical Reporting/Event Trigger Reporting Mode -Additional measurement list -CHOICE Measurement Type -Intra-frequency measurement - Intra-frequency measurement objects list -Intra-frequency cell info list -Intra-frequency measurement quantity -Filter coefficient -CHOICE mode -Measurement quantity -Intra-frequency reporting quantity -Reporting quantities for active set cells -Cell synchronization information reporting indicator -Cell Identity reporting indicator -CHOICE mode -Timeslot ISCP reporting indicator -Proposed TGSN Reporting required -PCCPCH RSCP reporting indicator -Pathloss reporting indicator -Reporting quantities for monitored set cells -Cell synchronization information reporting indicator -Cell Identity reporting indicator -CHOICE mode -Timeslot ISCP reporting indicator -Proposed TGSN Reporting required -PCCPCH RSCP reporting indicator -Pathloss reporting indicator -Reporting quantities for detected set cells -Reporting cell status -CHOICE reported cell -Maximum number of reported cells -Measurement validity -CHOICE report criteria -Amount of reporting -Reporting interval 1 setup Acknowledged mode RLC Periodical reporting Not Present Intra-frequency measurement Not Present 0 TDD PCCPCH RSCP TRUE TRUE TDD FALSE FALSE TRUE FALSE FALSE TRUE TDD FALSE FALSE TRUE FALSE Not Present Report all active set cells + cells within monitored set on used frequency Virtual/active set cells + 2 Not Present Periodical reporting criteria Infinity 250 ms Physical channel information elements -DPCH compressed mode status info Not Present Second MEASUREMENT CONTROL message for Inter frequency measurement (step 1) Information Element Value/Remark Message Type UE information elements -RRC transaction identifier 0 Measurement Information elements -Measurement Identity -Measurement Command -Measurement Reporting Mode - Measurement Report Transfer Mode - Periodical Reporting/Event Trigger Reporting Mode -Additional measurement list -CHOICE Measurement Type -Inter-frequency measurement object list -CHOICE Inter-frequency cell removal -New inter-frequency cells -Cell for measurement -Inter-frequency measurement quantity -CHOICE reporting criteria -Filter coefficient -CHOICE mode -Measurement quantity for frequency quality estimate -Inter-frequency reporting quantity -UTRA Carrier RSSI -Frequency quality estimate -Non frequency related cell reporting quantities -Cell synchronization information reporting indicator -Cell Identity reporting indicator -CHOICE mode -Timeslot ISCP reporting indicator -Proposed TGSN Reporting required -PCCPCH RSCP reporting indicator -Pathloss reporting indicator -Reporting cell status -CHOICE reported cell -Maximum number of reported cells -Measurement validity -Inter-frequency set update -CHOICE report criteria -Amount of reporting -Reporting interval 2 Setup Acknowledged mode RLC Periodical reporting Not Present Inter-frequency measurement Not Present Cell 2 information is included Not Present Inter-frequency reporting criteria 0 TDD PCCPCH RSCP TRUE TRUE TRUE TRUE TDD FALSE FALSE TRUE FALSE Report cells within monitored set on non-used frequency 2 Not Present Not Present Periodical reporting criteria Infinity 500 ms Physical channel information elements -DPCH compressed mode status info Not Present 8.7.1.2A.2.5 Test requirements Table 8.7.1.2A.2.2: P-CCPCH RSCP Inter frequency absolute accuracy Parameter Unit Accuracy [dB] Condition Normal Condition Extreme Condition Io[dBm/1.28 MHz] P-CCPCH_RSCP dBm  6  9 -94...-70 dBm  8  11 -70...-50 In each case, at least 900 of the 1000 measurement reports must meet the requirements. The rate of correct measurement observed during repeated tests shall be at least 90% with a confidence level of 95%. 8.7.1.2B Inter frequency measurement accuracy for 7,68 Mcps TDD Option 8.7.1.2B.1 Relative accuracy requirement 8.7.1.2B.1.1 Definition and applicability The P-CCPCH_RSCP inter-frequency relative accuracy is defined as the P-CCPCH_RSCP measured from one cell compared to the P-CCPCH_RSCP measured from another cell on a different frequency. The requirements and this test apply to all types of UTRA TDD UE. 8.7.1.2B.1.2 Minimum Requirements The relative accuracy requirements in table 8.7.1.2B.1.2.1 are valid under the following conditions: P-CCPCH RSCP  -102 dBm. Table 8.7.1.2B.1.2.1 P-CCPCH_RSCP inter-frequency relative accuracy Parameter Unit Accuracy [dB] Conditions Normal condition Extreme condition Io [dBm/7.68 MHz] P-CCPCH_RSCP dBm  6  6 -94...-50 The normative reference for this requirement is TS 25.123 [2] clauses 9.1.1.1.2.3 and A.9.3.1. 8.7.1.2B.1.3 Test Purpose The purpose of this test is to verify that the relative P-CCPCH RSCP measurement accuracy is within the specified limits for the inter frequency case. 8.7.1.2B.1.4 Method of test 8.7.1.2B.1.4.1 Initial conditions Test environment: normal, TL/VL, TL/VH, TH/VL, TH/VH; see clauses G.2.1 and G.2.2. Frequencies to be tested: mid range; see clause G.2.4. In this case both cells are on different frequencies. The second Beacon timeslot shall be provided in timeslot 8 for cell 1 and in timeslot 10 for cell 2. P-CCPCH RSCP inter frequency relative accuracy requirements are tested by using test parameters in table 8.7.1.2B.1.4.1.1. Table 8.7.1.2B.1.4.1.1: P-CCPCH RSCP inter frequency test parameters Parameter Unit Test 1 Test 2 Test 3 Cell 1 Cell 2 Cell 1 Cell 2 Cell 1 Cell 2 DL timeslot number 0 2 0 2 0 2 UTRA RF Channel number Channel 1 Channel 2 Channel 1 Channel 2 Channel 1 Channel 2 PCCPCH_Ec/Ior dB -3 -3 -3 SCH_Ec/Ior dB -9 -9 -9 SCH_toffset 0 5 0 5 0 5 OCNS_Ec/Ior dB -3,12 -3,12 -3,12 Ioc dBm / 7.68 MHz -75.2 -75.2 -57.8 -54.1 -98.7 -97 Îor/Ioc dB 5 5 7 2 3 0 PCCPCH RSCP, Note 1 dBm -73.2 -73.2 -54.8 -55.1 -98.7 -100 Io, Note 1 dBm / 7.68 MHz -69 -50 -94 Propagation condition AWGN AWGN AWGN NOTE 1: PCCPCH RSCP and Io levels have been calculated from other parameters for information purposes. They are not settable parameters themselves. 1) A call is set up according to the test procedure specified in TS 34.108 [3] clause 7.3.2.3. The RF parameters for Test 1 are set up according to table 8.7.1.2B.1.4.1.1. 8.7.1.2B.1.4.2 Procedure 1) SS shall transmit the MEASUREMENT CONTROL messages for intra frequency and inter frequency measurements. 2) UE shall transmit periodically MEASUREMENT REPORT messages. 3) SS shall check PCCPCH_RSCP value of Cell 1 and Cell 2 in MEASUREMENT REPORT messages. PCCPCH RSCP power value measured from Cell 1 is compared to PCCPCH RSCP power value measured from Cell 2 for each MEASUREMENT REPORT message. 4) The result of step 5) is compared to actual power level difference of PCCPCH RSCP of Cell 1 and Cell 2. 5) SS shall count number of MEASUREMENT REPORT messages transmitted by UE. After 1000 MEASUREMENT REPORT messages have been received from UE, the RF parameters are set up according to table 8.7.1.2.1.2 for Test 2. While RF parameters are being set up, MEASUREMENT REPORT messages from UE are ignored. SS shall wait for additional 1s and ignore the MEASUREMENT REPORT messages during this period. Then, steps 3) and 4) above are repeated. 6) After further 1000 MEASUREMENT REPORT messages have been received from UE, the SS shall transmit RRC CONNECTION RELEASE message. 7) UE shall transmit RRC CONNECTION RELEASE COMPLETE message. Specific Message Contents All messages indicated above shall use the same content as described in the default message content in clause 9 of 34.108 [3] and in Annex I, with the following exceptions: First MEASUREMENT CONTROL message for intra frequency measurements (Step 1): Information Element/Group name Value/Remark Message Type (10.2.17) UE information elements -RRC transaction identifier 0 -Integrity check info Not Present Measurement Information elements -Measurement Identity 1 -Measurement Command (10.3.7.46) Modify -Measurement Reporting Mode (10.3.7.49) -Measurement Report Transfer Mode AM RLC -Periodical Reporting / Event Trigger Reporting Mode Periodical reporting -Additional measurements list (10.3.7.1) Not Present -CHOICE Measurement type Intra-frequency measurement -Intra-frequency measurement (10.3.7.36) -Intra-frequency measurement objects list (10.3.7.33) Not Present -Intra-frequency measurement quantity (10.3.7.38) -Filter coefficient (10.3.7.9) 0 -CHOICE mode TDD -Measurement quantity list 1 -Measurement quantity Primary CCPCH RSCP -Intra-frequency reporting quantity (10.3.7.41) -Reporting quantities for active set cells (10.3.7.5) -SFN-SFN observed time difference reporting indicator No report -Cell synchronisation information reporting indicator FALSE -Cell Identity reporting indicator FALSE -CHOICE mode TDD -Timeslot ISCP reporting indicator FALSE -Primary CCPCH RSCP reporting indicator TRUE -Pathloss reporting indicator FALSE -Reporting quantities for monitored set cells (10.3.7.5) -SFN-SFN observed time difference reporting indicator No report -Cell synchronisation information reporting indicator FALSE -Cell Identity reporting indicator FALSE -CHOICE mode TDD -Timeslot ISCP reporting indicator FALSE -Proposed TGSN reporting required FALSE -Primary CCPCH RSCP reporting indicator TRUE -Pathloss reporting indicator FALSE -Reporting quantities for detected set cells (10.3.7.5) Not Present -Reporting cell status (10.3.7.61) -CHOICE reported cell Report all active set cells + cells within monitored set on used frequency -Maximum number of reported cells 1 -Measurement validity (10.3.7.51) Not Present -CHOICE report criteria (10.3.7. -Periodical reporting criteria (10.3.7.53) -Amount of reporting Infinity -Reporting interval 250 ms Physical channel information elements -DPCH compressed mode status info (10.3.6.34) Not Present Second MEASUREMENT CONTROL message for inter frequency measurements (Step 1): Information Element/Group name Value/Remark Message Type (10.2.17) UE information elements -RRC transaction identifier 0 -Integrity check info Not Present Measurement Information elements -Measurement Identity 2 -Measurement Command (10.3.7.46) Setup -Measurement Reporting Mode (10.3.7.49) -Measurement Report Transfer Mode AM RLC -Periodical Reporting / Event Trigger Reporting Mode Periodical reporting -Additional measurements list (10.3.7.1) Not Present -CHOICE Measurement type Inter-frequency measurement -Inter-frequency measurement (10.3.7.16) -Inter-frequency measurement objects list (10.3.7.13) -CHOICE inter-frequency cell removal Not present -New inter-frequency cells Cell 2 information is included -Cell for measurement Not Present -Inter-frequency measurement quantity (10.3.7.18) -CHOICE reporting critera Inter-frequency reporting criteria -Filter coefficient (10.3.7.9) 0 -CHOICE mode TDD -Measurement quantity for frequency quality estimate Primary CCPCH RSCP -Inter-frequency reporting quantity (10.3.7.21) -UTRA carrier RSSI FALSE -Frequency quality estimate TRUE -Non frequency related cell reporting quantities (10.3.7.5) -SFN-SFN observed time difference reporting indicator No report -Cell synchronisation information reporting indicator FALSE -Cell identity reporting indicator FALSE -CHOICE mode TDD -Timeslot ISCP reporting indicator FALSE -Proposed TGSN Reporting required FALSE -Primary CCPCH RSCP reporting indicator TRUE -Pathloss reporting indicator FALSE -Reporting cell status (10.3.7.61) -CHOICE reported cell Report all active set cells + cells within monitored set on used frequency -Maximum number of reported cells Virtual/active set cells + 2 -Measurement validity (10.3.7.51) Not present -Inter-frequency set update Not present -CHOICE report criteria (10.3.7. -Periodical reporting criteria (10.3.7.53) -Amount of reporting Infinity -Reporting interval 500 ms Physical channel information elements -DPCH compressed mode status info (10.3.6.34) Not Present 8.7.1.2B.1.5 Test requirements The PCCPCH RSCP measurement accuracy shall meet the requirements in clause 8.7.1.2B.1.2 for at least 900 of the measurement reports at each input level in step 4. NOTE: If the above Test Requirement differs from the Minimum Requirement then the Test Tolerance applied for this test is non-zero. The Test Tolerance for this test is defined in clause F.2 and the explanation of how the Minimum Requirement has been relaxed by the Test Tolerance is given in clause F.4.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.1.3 Local cell accuracy for 3.84 Mcps TDD option
Void 8.7.1.3A Local cell cccuracy for 1.28 Mcps TDD option 8.7.1.3A.1 Absolute accuracy requirement 8.7.1.3A.1.1 Definition and applicability The absolute accuracy of P-CCPCH RSCP is defined as the P-CCPCH RSCP measured from one cell compared to the actual P-CCPCH RSCP power from the same cell. The requirements and this test apply to all types of 1.28 Mcps TDD UE. 8.7.1.3A.1.2 Minimum Requirements Parameter Unit Accuracy Condition Normal Condition Extreme Condition Io[dBm/1.28 MHz] P-CCPCH_RSCP dBm  6  9 -94...-70 dBm  8  11 -70...-50 8.7.1.3A.1.3 Test purpose The purpose of this test is to verify that the Single-Cell Absolute Accuracy is within the specified limits. 8.7.1.3A.1.4 Method of test 8.7.1.3A.1.4.1 Initial conditions Test environment: normal, TL/VL, TL/VH, TH/VL, TH/VH; see clauses G.2.1 and G.2.2. Frequencies to be tested: mid range; see clause G.2.4. Cell condition: One 1.28Mcps TDD cell must be configured. The DL DPCH is configured in timeslot 5, and the UL DPCH is configured in timeslot 2. P-CCPCH RSCP –102 dBm. Table 8.7.1.3A.1.1: P-CCPCH RSCP local cell test parameters Test 1 Parameter Unit Cell 1 Timeslot Number 0 DwPTS UTRA RF Channel Number Channel 1 PCCPCH_Ec/Ior dB 0 DwPCH_Ec/Ior dB 0 dBm/1.28 MHz –76.6 PCCPCH RSCP dBm –76.6 Test 2 Parameter Unit Cell 1 Timeslot Number 0 DwPTS UTRA RF Channel Number Channel 1 PCCPCH_Ec/Ior dB 0 DwPCH_Ec/Ior dB 0 dBm/1.28 MHz –85 PCCPCH RSCP dBm –85 Test 3 Parameter Unit Cell 1 Timeslot Number 0 DwPTS UTRA RF Channel Number Channel 1 PCCPCH_Ec/Ior dB 0 DwPCH_Ec/Ior dB 0 dBm/1.28 MHz –90 PCCPCH RSCP dBm –90 Test 4 Parameter Unit Cell 1 Timeslot Number 0 DwPTS UTRA RF Channel Number Channel 1 PCCPCH_Ec/Ior dB 0 DwPCH_Ec/Ior dB 0 dBm/1.28 MHz –95 PCCPCH RSCP dBm –95 MEASUREMENT CONTROL message in P-CCPCH RSCP absolute accuracy measurement (step 1) Information Element/Group Name Value/Remark Message Type (10.2.17) UE information elements -RRC transaction identifier 0 -Integrity check info Not Present Measurement Information elements -Measurement Identity 1 -Measurement Command (10.3.7.46) setup -Measurement Reporting Mode (10.3.7.49) -Measurement Report Transfer Mode AM RLC -Periodical Reporting/Event Trigger Reporting Mode Periodical reporting -Additional measurements list (10.3.7.1) Not Present -CHOICE Measurement type Intra-frequency measurement -Intra-frequency measurement (10.3.7.36) -Intra-frequency measurement objects list (10.3.7.33) Not Present -Intra-frequency measurement quantity (10.3.7.38) -Filter coefficient (10.3.7.9) 0 -CHOICE mode TDD -Measurement quantity list 1 -Measurement quantity Primary CCPCH RSCP -Intra-frequency reporting quantity (10.3.7.41) -Reporting quantities for active set cells (10.3.7.5) -SFN-SFN observed time difference reporting indicator No report -Cell synchronization information reporting indicator FALSE -Cell Identity reporting indicator TRUE -CHOICE mode TDD -Timeslot ISCP reporting indicator FALSE -Primary CCPCH RSCP reporting indicator TRUE -Pathloss reporting indicator FALSE -Reporting quantities for monitored set cells (10.3.7.5) -SFN-SFN observed time difference reporting indicator No report -Cell synchronization information reporting indicator FALSE -Cell Identity reporting indicator TRUE -CHOICE mode TDD -Timeslot ISCP reporting indicator FALSE -Proposed TGSN reporting required FALSE -Primary CCPCH RSCP reporting indicator TRUE -Pathloss reporting indicator FALSE -Reporting quantities for detected set cells (10.3.7.5) Not Present -Reporting cell status (10.3.7.61) -CHOICE reported cell Report all active set cells + cells within monitored set on used frequency -Maximum number of reported cells 1 -Measurement validity (10.3.7.51) Not Present -CHOICE report criteria (10.3.7. -Periodical reporting criteria (10.3.7.53) -Amount of reporting Infinity -Reporting interval 250 ms Physical channel information elements -DPCH compressed mode status info (10.3.6.34) Not Present 8.7.1.3A.1.4.2 Procedure 1) A call is set up according to the test procedure specified in 3GPP TS 34.108 sub-clause 7.3.2.3. The RF parameters for Test 1 are set up according to table1. 2) SS shall transmit MEASUREMENT CONTROL message. 3) UE shall transmit periodically MEASUREMENT REPORT messages. 4) SS shall check PCCPCH_RSCP value in MEASUREMENT REPORT messages. PCCPCH_RSCP power of Cell 1 reported by UE is compared to actual PCCPCH_RSCP power for each MEASUREMENT REPORT message. 5) SS shall count number of MEASUREMENT REPORT messages transmitted by UE. After 1000 MEASUREMENT REPORT messages have been received from UE, the RF parameters are set up according to table1 for Test 2. While RF parameters are being set up, MEASUREMENT REPORT messages from UE are ignored. SS shall wait for additional 1s and ignore the MEASUREMENT REPORT messages during this period. Then, repeat steps 3 and 4. After further 1000 MEASUREMENT REPORT messages have been received from UE, the RF parameters are set up according to table1 for Test 3. While RF parameters are being set up, MEASUREMENT REPORT messages from UE are ignored. SS shall wait for additional 1s and ignore the MEASUREMENT REPORT messages during this period. Then, steps 3 and 4 are repeated. 6) After further 1000 MEASUREMENT REPORT messages have been received from UE, the SS shall transmit RRC CONNECTION RELEASE message. 7) UE shall transmit RRC CONNECTION RELEASE COMPLETE message. 8.7.1.3A.1.5 Test requirements Parameter Unit Accuracy Condition Normal Condition Extreme Condition Io[dBm/1.28 MHz] P-CCPCH_RSCP dBm  6  9 -94...-70 dBm  8  11 -70...-50 The success rate shall be more than 90% and the confidence level shall be more than 95%. 8.7.1.3B Local cell accuracy for 7.86 Mcps TDD option Void
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.1.4 Local cell absolute accuracy in white noise for 3.84 Mcps TDD
Void 8.7.1.4A Local cell absolute accuracy in white noise for 1.28 Mcps TDD 8.7.1.4A.1 Absolute accuracy requirement 8.7.1.4A.1.1 Definition and applicability The absolute accuracy of P-CCPCH RSCP is defined as the P-CCPCH RSCP measured from one cell compared to the actual P-CCPCH RSCP power from the same cell. The requirements and this test apply to all types of 1.28 Mcps TDD UE. 8.7.1.4A.1.2 Minimum Requirements Parameter Unit Accuracy Condition Normal condition Extreme condition Io[dBm/1.28 MHz] P-CCPCH_RSCP dBm  6  9 -94...-70 dBm  8  11 -70...-50 8.7.1.4A.1.3 Test purpose The purpose of this test is to verify that the Single-Cell White Noise Environment Measurement Absolute Accuracy is within the specified limits. 8.7.1.4A.1.4 Method of test 8.7.1.4A.1.4.1 Initial conditions Test environment: normal, TL/VL, TL/VH, TH/VL, TH/VH; see clauses G.2.1 and G.2.2. Frequencies to be tested: mid range; see clause G.2.4. Cell condition: One 1.28Mcps TDD cell must be configured. The DL DPCH is configured in timeslot 5, and the UL DPCH is configured in timeslot 2. Table 8.7.1.4A.1.1: P-CCPCH RSCP single-cell white noise measurement parameters Test 1 Parameter Unit Cell 1 Timeslot Number 0 DwPTS UTRA RF Channel Number Channel 1 PCCPCH_Ec/Ior dB 0 DwPCH_Ec/Ior dB 0 dB 2 dBm/1.28 MHz –76.6 PCCPCH RSCP (Note 1) dBm –74.6 Propagation condition AWGN Test 2 Parameter Unit Cell 1 Timeslot Number 0 DwPTS UTRA RF Channel Number Channel 1 PCCPCH_Ec/Ior dB 0 DwPCH_Ec/Ior dB 0 dB 2 dBm/1.28 MHz –87 PCCPCH RSCP (Note 1) dBm –85 Propagation condition AWGN Test 3 Parameter Unit Cell 1 Timeslot Number 0 DwPTS UTRA RF Channel Number Channel 1 PCCPCH_Ec/Ior dB 0 DwPCH_Ec/Ior dB 0 dB 2 dBm/1.28 MHz –92 PCCPCH RSCP (Note 1) dBm –90 Propagation condition AWGN Test 4 Parameter Unit Cell 1 Timeslot Number 0 DwPTS UTRA RF Channel Number Channel 1 PCCPCH_Ec/Ior dB 0 DwPCH_Ec/Ior dB 0 dB 2 dBm/1.28 MHz –97 PCCPCH RSCP (Note 1) dBm –95 Propagation condition AWGN Note 1: PCCPCH RSCP and Io levels are calculated from other parameters for information purposes. MEASUREMENT CONTROL message in P-CCPCH RSCP absolute accuracy measurement (step 1) Information Element/Group Name Value/Remark Message Type (10.2.17) UE information elements -RRC transaction identifier 0 -Integrity check info Not Present Measurement Information elements -Measurement Identity 1 -Measurement Command (10.3.7.46) setup -Measurement Reporting Mode (10.3.7.49) -Measurement Report Transfer Mode AM RLC -Periodical Reporting/Event Trigger Reporting Mode Periodical reporting -Additional measurements list (10.3.7.1) Not Present -CHOICE Measurement type Intra-frequency measurement -Intra-frequency measurement (10.3.7.36) -Intra-frequency measurement objects list (10.3.7.33) Not Present -Intra-frequency measurement quantity (10.3.7.38) -Filter coefficient (10.3.7.9) 0 -CHOICE mode TDD -Measurement quantity list 1 -Measurement quantity Primary CCPCH RSCP -Intra-frequency reporting quantity (10.3.7.41) -Reporting quantities for active set cells (10.3.7.5) -SFN-SFN observed time difference reporting indicator No report -Cell synchronization information reporting indicator FALSE -Cell Identity reporting indicator TRUE -CHOICE mode TDD -Timeslot ISCP reporting indicator FALSE -Primary CCPCH RSCP reporting indicator TRUE -Pathloss reporting indicator FALSE -Reporting quantities for monitored set cells (10.3.7.5) -SFN-SFN observed time difference reporting indicator No report -Cell synchronization information reporting indicator FALSE -Cell Identity reporting indicator TRUE -CHOICE mode TDD -Timeslot ISCP reporting indicator FALSE -Proposed TGSN reporting required FALSE -Primary CCPCH RSCP reporting indicator TRUE -Pathloss reporting indicator FALSE -Reporting quantities for detected set cells (10.3.7.5) Not Present -Reporting cell status (10.3.7.61) -CHOICE reported cell Report all active set cells + cells within monitored set on used frequency -Maximum number of reported cells 1 -Measurement validity (10.3.7.51) Not Present -CHOICE report criteria (10.3.7. -Periodical reporting criteria (10.3.7.53) -Amount of reporting Infinity -Reporting interval 250 ms Physical channel information elements -DPCH compressed mode status info (10.3.6.34) Not Present 8.7.1.4A.1.4.2 Procedure 1) A call is set up according to the test procedure specified in 3GPP TS 34.108 sub-clause 7.3.2.3. The RF parameters for Test 1 are set up according to table1. 2) SS shall transmit MEASUREMENT CONTROL message. 3) UE shall transmit periodically MEASUREMENT REPORT messages. 4) SS shall check PCCPCH_RSCP value in MEASUREMENT REPORT messages. PCCPCH_RSCP power of Cell 1 reported by UE is compared to actual PCCPCH_RSCP power for each MEASUREMENT REPORT message. 5) SS shall count number of MEASUREMENT REPORT messages transmitted by UE. After 1000 MEASUREMENT REPORT messages have been received from UE, the RF parameters are set up according to table1 for Test 2. While RF parameters are set up, MEASUREMENT REPORT messages from UE are ignored. SS shall wait for additional 1s and ignore the MEASUREMENT REPORT messages during this period. Then, repeat steps 3 and 4. After further 1000 MEASUREMENT REPORT messages have been received from UE, the RF parameters are set up according to table1 for Test 3. While RF parameters are set up, MEASUREMENT REPORT messages from UE are ignored. SS shall wait for additional 1s and ignore the MEASUREMENT REPORT messages during this period. Then, repeat steps 3 and 4. 6) After further 1000 MEASUREMENT REPORT messages have been received from UE, the SS shall transmit RRC CONNECTION RELEASE message. 7) UE shall transmit RRC CONNECTION RELEASE COMPLETE message. 8.7.1.4A.1.5 Test requirements Parameter Unit Accuracy Condition Normal condition Extreme condition Io[dBm/1.28 MHz] P-CCPCH_RSCP dBm  6  9 -94...-70 dBm  8  11 -70...-50 The success rate shall be more than 90% and the confidence level shall be more than 95%. 8.7.1.4B Local cell absolute accuracy in white noise for 3.84 Mcps TDD Void
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.2 CPICH measurements (FDD)
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.2.1 CPICH RSCP
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.2.1.1 Absolute measurement accuracy for 3,84 Mcps TDD Option
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.2.1.1.1 Definition and applicability
The absolute accuracy of CPICH RSCP is defined as the CPICH RSCP measured in an UTRA FDD cell on one frequency compared to the actual CPICH RSCP power of that cell on the same frequency. The requirements and this test apply only to UE supporting both UTRA TDD and UTRA FDD.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.2.1.1.2 Minimum Requirements
The accuracy requirements in table 8.7.2.1.1.1 are valid under the following conditions: - CPICH_RSCP1,2|dBm  -114 dBm. - . Table 8.7.2.1.1.1: CPICH RSCP inter frequency absolute accuracy Parameter Unit Accuracy [dB] Conditions Normal condition Extreme condition Io [dBm/ 3,84 MHz] CPICH_RSCP dBm  6  9 -94...-70 dBm  8  11 -70...-50 The normative reference for this requirement is TS 25.123 [2] clauses 9.1.1.2.1 and A.9.1.2.1.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.2.1.1.3 Test purpose
The purpose of this test is to verify that the CPICH RSCP absolute measurement accuracy is within the specified limits.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.2.1.1.4 Method of test
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.2.1.1.4.1 Initial conditions
Test environment: normal, TL/VL, TL/VH, TH/VL, TH/VH; see clauses G.2.1 and G.2.2. Frequencies to be tested: mid range; see clause G.2.4. In this case both cells are on different frequencies. Cell 1 is a UTRA TDD cell and cell 2 is a UTRA FDD cell. The DL DPCH shall be transmitted in timeslot 1 and the UL DPCH shall be transmitted in timeslot 3. No second Beacon timeslot shall be provided for cell 1. CPICH RSCP inter frequency absolute accuracy requirements are tested by using test parameters in table 8.7.2.1.1.2. Table 8.7.2.1.1.2: CPICH RSCP inter frequency tests parameters Parameter Unit Test 1 Test 2 Cell 1 Cell 2 Cell 1 Cell 2 DL timeslot number 0 n.a. 0 n.a. UTRA RF Channel number Channel 1 Channel 2 Channel 1 Channel 2 CPICH_Ec/Ior dB n.a. -10 n.a. -10 PCCPCH_Ec/Ior dB -3 -12 -3 -12 SCH_Ec/Ior dB -9 -12 -9 -12 SCH_toffset 5 n.a. 5 n.a. PICH_Ec/Ior dB n.a. -15 n.a. -15 OCNS_Ec/Ior dB -3.12 -0.94 -3.12 -0.94 Ioc dBm/ 3,84 MHz -57.7 -60 -84.7 -84 Îor/Ioc dB 7 9.54 3 0 PCCPCH RSCP, Note 1 dBm -53.7 n.a. -84.7 n.a. CPICH RSCP, Note 1 dBm n.a. -60.46 n.a. -94 Io, Note 1 dBm/ 3,84 MHz -50 -50 -80 -81 Propagation condition - AWGN AWGN NOTE 1: PCCPCH RSCP, CPICH RSCP and Io levels have been calculated from other parameters for information purposes. They are not settable parameters themselves. A call is set up according to the test procedure specified in TS 34.108 [3] clause 7.3.2.3. The RF parameters for Test 1 are set up according to table 8.7.2.1.1.2.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.2.1.1.4.2 Procedure
1) SS shall transmit the MEASUREMENT CONTROL message for inter frequency measurement. 2) UE shall transmit periodically MEASUREMENT REPORT messages. 3) SS shall check CPICH RSCP value of Cell 2 in the MEASUREMENT REPORT messages. CPICH RSCP levels of Cell 2 reported by the UE is compared to the actual CPICH RSCP value of Cell 2 for each MEASUREMENT REPORT message. 4) SS shall count number of MEASUREMENT REPORT messages transmitted by UE. After 1000 MEASUREMENT REPORT messages have been received from UE, the RF parameters are set up according to table 8.7.2.1.1.2 for Test 2. While RF parameters are being set up, MEASUREMENT REPORT messages from UE are ignored. SS shall wait for additional 1s and ignore the MEASUREMENT REPORT messages during this period. Then, steps 2) and 3) above are repeated. 6) After further 1000 MEASUREMENT REPORT messages have been received from UE, the SS shall transmit RRC CONNECTION RELEASE message. 7) UE shall transmit RRC CONNECTION RELEASE COMPLETE message. Specific Message Contents All messages indicated above shall use the same content as described in the default message content in clause 9 of 34.108 [3] and in Annex I, with the following exceptions: MEASUREMENT CONTROL message for inter frequency measurement (Step 1): Information Element Value/Remark Message Type UE information elements -RRC transaction identifier -Integrity check info 0 Not Present Measurement Information elements -Measurement Identity -Measurement Command -Measurement Reporting Mode - Measurement Report Transfer Mode - Periodical Reporting / Event Trigger Reporting Mode -Additional measurement list -CHOICE Measurement Type -Inter-frequency measurement object list -CHOICE Inter-frequency cell removal -New inter-frequency cells -Cell for measurement -Inter-frequency measurement quantity -CHOICE reporting criteria -Filter coefficient -CHOICE mode -Measurement quantity for frequency quality estimate -Inter-frequency reporting quantity -UTRA Carrier RSSI -Frequency quality estimate -Non frequency related cell reporting quantities -SFN-SFN observed time difference reporting indicator -Cell synchronisation information reporting indicator -Cell Identity reporting indicator -CHOICE mode -CPICH Ec/N0 reporting indicator -CPICH RSCP reporting indicator -Pathloss reporting indicator -Reporting cell status -CHOICE reported cell -Maximum number of reported cells -Measurement validity -Inter-frequency set update -CHOICE report criteria -Amount of reporting -Reporting interval 2 Setup Acknowledged mode RLC Periodical reporting Not Present Inter-frequency measurement Not Present Cell 2 information is included Not Present Inter-frequency reporting criteria 0 FDD CPICH RSCP FALSE TRUE No report FALSE FALSE FDD FALSE TRUE FALSE Report all active set cells + cells within monitored set on used frequency Virtual/active set cells + 2 Not Present Not Present Periodical reporting criteria Infinity 500 ms Physical channel information elements -DPCH compressed mode status info Not Present
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.2.1.1.5 Test requirements
The RX_LEV measurement accuracy shall meet the requirements in clause 8.7.5.1A.1.1 for at least 900 of the reported levels at each input level. NOTE: If the above Test Requirement differs from the Minimum Requirement then the Test Tolerance applied for this test is non-zero. The Test Tolerance for this test is defined in clause F.2 and the explanation of how the Minimum Requirement has been relaxed by the Test Tolerance is given in clause F.4. 8.7.5.1B.1 RSSI (RX_LEV) 7,68 Mcps TDD Option 8.7.5.1B.1.1 Definition and applicability Cell 1 is a UTRA TDD cell and cell 2 is a GSM cell. In the measurement control information it is indicated to the UE that periodic reporting of the GSM carrier RSSI measurement is used. The requirements and this test apply only to UE supporting both 7,68Mcps UTRA TDD and GSM. 8.7.5.1B.1.2 Minimum Requirements Table 8.7.5.1B.1.2.1: GSM RX_LEV absolute accuracy Parameter Unit Accuracy [dB] Conditions Normal condition Extreme condition Input level dBm RX_LEV dBm  4  6 -110…-70 dBm  6  6 -70…-48 dBm  9  9 -48..-38 RXLEV 0 = less than ‑110 dBm. RXLEV 1 = ‑110 dBm to ‑109 dBm RXLEV 2 = ‑109 dBm to ‑108 dBm : : RXLEV 62 = ‑49 dBm to ‑48 dBm RXLEV 63 = greater than ‑48 dBm The normative reference for this requirement is TS 45.008 [20] clause 8.1.2 8.7.5.1B.1.3 Test purpose The purpose of this test is to verify that the GSM RSSI absolute measurement accuracy is within the specified limits. This test will verify the requirements in section 9.1.1.5 and A.9.3.5 of TS25.123. 8.7.5.1B.1.4 Method of test 8.7.5.1B.1.4.1 Initial conditions Test environment: normal, TL/VL, TL/VH, TH/VL, TH/VH; see clauses G.2.1 and G.2.2. Frequencies to be tested: mid range; see clause G.2.4. Cell 1 is a UTRA 1,28Mcps TDD cell and cell 2 is a GSM cell A call is set up according to the test procedure specified in TS 34.108 [3] clause 7.3.2.3. The RF parameters for Test are set up according to table 8.7.5.1B.1.4.1.1, 8.7.5.1B.1.4.1.2 and 8.7.5.1B.1.4.1.3. Table 8.7.5.1B.1.4.1.1 General GSM RSSI test parameters Parameter Unit Value Comment DCH parameters DL reference measurement channel 12.2 kbps As specified in TS 25.102 section A.2.2 Power Control On Target quality value on DTCH BLER 0.01 Inter-RAT measurement quantity GSM carrier RSSI BSIC verification required No Monitored cell list size 6 GSM neighbours including ARFCN 1 Table 8.7.5.1B.1.4.1.2 Cell 1 (TDD Cell) specific test parameters Parameter Unit Cell 1 DL timeslot number 0 1 UTRA RF Channel number Channel 1 PCCPCH_Ec/Ior dB -3 n.a. SCH_Ec/Ior dB -9 n.a. SCH_toffset 0 n.a. OCNS_Ec/Ior dB -3,12 Note 2 DPCH_Ec/Ior dB n.a. Note 1 Îor/Ioc dB 6 6 Io, Note 1 dBm / 7.68 MHz -70 Propagation condition AWGN Note 1: The DPCH level is controlled by the power control loop Note 2: The power of the OCNS channel that is added shall make the total power from the cell to be equal to Ior. Table 8.7.5.1B.1.4.1.3 Cell 2 specific GSM Cell test parameters Parameter Unit TEST1 TEST2 TEST3 UTRA RF Channel number 2 Cell Level dBm/200KHz -100 -75 -50 Propagation condition AWGN AWGN AWGN 8.7.5.1B.1.4.2 Procedure 1) SS shall transmit the MEASUREMENT CONTROL message for inter RAT measurement. In the measurement control information periodic reporting of the GSM carrier RSSI is requested to the UE. 2) UE shall transmit periodically MEASUREMENT REPORT messages. 3) SS shall check RX_LEV value of Cell 2 in the MEASUREMENT REPORT messages. Levels of Cell 2 reported by the UE are compared to the actual level of Cell 2 for each MEASUREMENT REPORT message. 4) SS shall count number of MEASUREMENT REPORT messages transmitted by UE. After 1000 MEASUREMENT REPORT messages have been received from UE, the GSM cell RF parameters are set up according to table 8.7.5.1B.1.4.1.3 for Test 2. While RF parameters are being set up, MEASUREMENT REPORT messages from UE are ignored. SS shall wait for additional 1s and ignore the MEASUREMENT REPORT messages during this period. Then, steps 2) and 3) above are repeated. 6) After further 1000 MEASUREMENT REPORT messages have been received from UE, the GSM cell RF parameters are set up according to table 8.7.5.1B.1.4.1.3 for Test 3. While RF parameters are being set up, MEASUREMENT REPORT messages from UE are ignored. SS shall wait for additional 1s and ignore the MEASUREMENT REPORT messages during this period. Then, steps 2) and 3) above are repeated. 7) After further 1000 MEASUREMENT REPORT messages have been received from UE, the SS shall transmit RRC CONNECTION RELEASE message. 8) UE shall transmit RRC CONNECTION RELEASE COMPLETE message. Specific Message Contents All messages indicated above shall use the same content as described in the default message content in clause 9 of 34.108 [3], with the following exceptions: Note: Numbers in brackets after an item e.g “Message Type (10.2.17)” in the IE description are references to clause numbers in TS 25.331 [9] describing that item in more detail. MEASUREMENT CONTROL message for GSM RSSI measurement (Step 1): Information Element Value/Remark Message Type (10.2.17) UE information elements -RRC transaction identifier -Integrity check info 0 Not Present Measurement Information elements -Measurement Identity -Measurement Command -Measurement Reporting Mode - Measurement Report Transfer Mode - Periodical Reporting / Event Trigger Reporting Mode -Additional measurement list -CHOICE Measurement Type -Inter-frequency measurement object list -CHOICE Inter-frequency cell removal -New inter-frequency cells -Cell for measurement -Inter-frequency measurement quantity -CHOICE reporting criteria -Filter coefficient -CHOICE mode -Measurement quantity -Inter-frequency reporting quantity -UTRA Carrier RSSI -Frequency quality estimate -Non frequency related cell reporting quantities -SFN-SFN observed time difference reporting indicator -Cell synchronisation information reporting indicator -Maximum number of reported cells -Measurement validity -Inter-frequency set update -CHOICE report criteria -Amount of reporting -Reporting interval 2 Setup Acknowledged mode RLC Periodical reporting Not Present Inter-RAT measurement Not Present Cell 2 information is included Not Present Inter-frequency reporting criteria 0 GSM RX_LEV FALSE FALSE No report Report all active set cells + cells within monitored set on used frequency Virtual/active set cells + 2 Not Present Not Present Periodical reporting criteria Infinity 500 ms Physical channel information elements -DPCH compressed mode status info Not Present 8.7.5.1B.1.5 Test requirements The RX_LEV measurement accuracy shall meet the requirements in clause 8.7.5.1B.1.2 for at least 900 of the reported levels at each input level. NOTE: If the above Test Requirement differs from the Minimum Requirement then the Test Tolerance applied for this test is non-zero. The Test Tolerance for this test is defined in clause F.2 and the explanation of how the Minimum Requirement has been relaxed by the Test Tolerance is given in clause F.4.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.2.2 CPICH Ec/Io
Void NOTE: This section is included for consistency with numbering in TS 25.123 [2] currently no test covering requirements in section 9.1.1.3 of [2]exists.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.3 Timeslot ISCP
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.3.1 Intra frequency measurement accuracy for 3,84 Mcps TDD Option
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.3.1.1 Absolute accuracy requirement
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.3.1.1.1 Definition and applicability
The absolute accuracy of Timeslot ISCP is defined as the Timeslot ISCP meaasured from one cell / timeslot combination compared to the actual Timeslot ISCP level for the same cell / timeslot combination. The requirements and this test apply to all types of UTRA TDD UE.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.3.1.1.2 Minimum Requirements
The absolute accuracy requirements in table 8.7.3.1.1.1 are valid under the following conditions: P-CCPCH RSCP  -102 dBm. Table 8.7.3.1.1.1: UE Timeslot ISCP intra frequency absolute accuracy (3,84Mcps option) Parameter Unit Accuracy [dB] Conditions Normal condition Extreme condition Io [dBm/ 3.84 MHz] Timeslot_ISCP dBm  6  9 -94...-70 dBm  8  11 -70...-50 The normative reference for this requirement is TS 25.123 [2] clauses 9.2.1.2.1.1 and A.9.1.3.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.3.1.1.3 Test Purpose
The purpose of this test is to verify that the Timeslot ISCP measurement accuracy is within the specified limits.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.3.1.1.4 Method of test
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.3.1.1.4.1 Initial conditions
Test environment: normal, TL/VL, TL/VH, TH/VL, TH/VH; see clauses G.2.1 and G.2.2. Frequencies to be tested: mid range; see clause G.2.4. In this case all cells are on the same frequency. Cell 1 and cell 2 shall be synchronised, i.e. share the same frame and timeslot timing. The DL DPCH shall be transmitted in timeslot 4 and the UL DPCH shall be transmitted in timeslot 12. The second Beacon timeslot shall be provided in timeslot 8 for both cell 1 and cell 2. The Timeslot ISCP intra frequency absolute accuracy requirements are tested by using test parameters in table 8.7.3.1.1.2. Table 8.7.3.1.1.2: Timeslot ISCP intra frequency test parameters Parameter Unit Test 1 Test 2 Test 3 Cell 1 Cell 2 Cell 1 Cell 2 Cell 1 Cell 2 DL timeslot number 0 0 0 0 0 0 UTRA RF Channel number Channel 1 Channel 1 Channel 1 PCCPCH_Ec/Ior dB -3 -3 -3 SCH_Ec/Ior dB -9 -9 -9 SCH_toffset 0 5 0 5 0 5 OCNS_Ec/Ior dB -3,12 -3,12 -3,12 Ioc dBm / 3,84 MHz -75.7 -59.8 -98.7 Îor/Ioc dB 5 2 9 2 3 0 Timeslot ISCP, Note 1 dBm -73.7 -70.7 -57.8 -50.8 -98.7 -95.7 Io, Note 1 dBm / 3,84 MHz -69 -50 -94 Propagation condition AWGN AWGN AWGN NOTE 1: Timeslot ISCP and Io levels have been calculated from other parameters for information purposes. They are not settable parameters themselves. 1) A call is set up according to the test procedure specified in TS 34.108 [3] clause 7.3.2.3. The RF parameters for Test 1 are set up according to table 8.7.3.1.1.2.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.3.1.1.4.2 Procedure
1) SS shall transmit MEASUREMENT CONTROL message. 2) UE shall transmit periodically MEASUREMENT REPORT messages. 3) SS shall check Timeslot ISCP values for Cell 1 / Timeslot 0 and Cell 2 / Timeslot 0 combinations in MEASUREMENT REPORT messages. These Timeslot ISCP values reported by the UE are compared to the actual Timeslot ISCP levels for each MEASUREMENT REPORT message. 4) SS shall count number of MEASUREMENT REPORT messages transmitted by UE. After 1000 MEASUREMENT REPORT messages have been received from UE, the RF parameters are set up according to table 8.7.3.1.1.2 for Test 2. While RF parameters are being set up, MEASUREMENT REPORT messages from UE are ignored. SS shall wait for additional 1s and ignore the MEASUREMENT REPORT messages during this period. Then, steps 2) and 3) above are repeated. After further 1000 MEASUREMENT REPORT messages have been received from UE, the RF parameters are set up according to table 8.7.3.1.1.2 for Test 3. While RF parameters are being set up, MEASUREMENT REPORT messages from UE are ignored. SS shall wait for additional 1s and ignore the MEASUREMENT REPORT messages during this period. Then, steps 2) and 3) above are repeated. 5) After further 1000 MEASUREMENT REPORT messages have been received from UE, the SS shall transmit RRC CONNECTION RELEASE message. 6) UE shall transmit RRC CONNECTION RELEASE COMPLETE message. Specific Message Contents All messages indicated above shall use the same content as described in the default message content in clause 9 of 34.108 [3] and in Annex I, with the following exceptions: MEASUREMENT CONTROL message (Step 1): Information Element/Group name Value/Remark Message Type (10.2.17) UE information elements -RRC transaction identifier 0 -Integrity check info Not Present Measurement Information elements -Measurement Identity 1 -Measurement Command (10.3.7.46) Modify -Measurement Reporting Mode (10.3.7.49) -Measurement Report Transfer Mode AM RLC -Periodical Reporting / Event Trigger Reporting Mode Periodical reporting -Additional measurements list (10.3.7.1) Not Present -CHOICE Measurement type Intra-frequency measurement -Intra-frequency measurement (10.3.7.36) -Intra-frequency measurement objects list (10.3.7.33) -CHOICE Intra-frequency cell removal Not present -New intra-frequency cells 2 -Intra-frequency cell id 1 -Cell info -Cell individual offset 0 -Reference time difference to cell Not present -Read SFN indicator FALSE -CHOICE mode TDD -Primary CCPCH info (10.3.6.57) -CHOICE mode TDD -CHOICE TDD option 3,84 Mcps TDD -CHOICE Sync case 2 -Timeslot 0 -Cell parameters ID Set to cell parameter ID of cell 1 -SCTD indicator FALSE -Primary CCPCH Tx power Set to Primary CCPCH Tx power of cell 1 as described in Table 8.7.3.1.2. -Timeslot number 0 -Burst type 1 -Intra-frequency cell id 2 -Cell info -Cell individual offset 0 -Reference time difference to cell Not present -Read SFN indicator FALSE -CHOICE mode TDD -Primary CCPCH info (10.3.6.57) -CHOICE mode TDD -CHOICE TDD option 3,84 Mcps TDD -CHOICE Sync case 2 -Timeslot 0 -Cell parameters ID Set to cell parameter ID of cell 2 -SCTD indicator FALSE -Primary CCPCH Tx power Set to Primary CCPCH Tx power of cell 2 as described in Table 8.7.3.1.2. -Timeslot number 0 -Burst type 1 -Intra-frequency measurement quantity (10.3.7.38) -Filter coefficient (10.3.7.9) 0 -CHOICE mode TDD -Measurement quantity list 1 -Measurement quantity Timeslot ISCP -Intra-frequency reporting quantity (10.3.7.41) -Reporting quantities for active set cells (10.3.7.5) -SFN-SFN observed time difference reporting indicator No report -Cell synchronisation information reporting indicator FALSE -Cell Identity reporting indicator FALSE -CHOICE mode TDD -Timeslot ISCP reporting indicator TRUE -Primary CCPCH RSCP reporting indicator TRUE -Pathloss reporting indicator FALSE -Reporting quantities for monitored set cells (10.3.7.5) -SFN-SFN observed time difference reporting indicator No report -Cell synchronisation information reporting indicator FALSE -Cell Identity reporting indicator FALSE -CHOICE mode TDD -Timeslot ISCP reporting indicator TRUE -Proposed TGSN reporting required FALSE -Primary CCPCH RSCP reporting indicator TRUE -Pathloss reporting indicator FALSE -Reporting quantities for detected set cells (10.3.7.5) Not Present -Reporting cell status (10.3.7.61) -CHOICE reported cell Report all active set cells + cells within monitored set on used frequency -Maximum number of reported cells Virtual / active set cells + 1 -Measurement validity (10.3.7.51) Not Present -CHOICE report criteria (10.3.7. -Periodical reporting criteria (10.3.7.53) -Amount of reporting Infinity -Reporting interval 500 ms Physical channel information elements -DPCH compressed mode status info (10.3.6.34) Not Present
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.3.1.1.5 Test requirements
The Timeslot ISCP measurement accuracy shall meet the requirements in clause 8.7.3.1.1.2 for at least 900 of the reported Timeslot ISCP levels at each input level in step 4 for both Cell 1 / Timeslot 0 and Cell 2 / Timeslot 0 combinations. NOTE: If the above Test Requirement differs from the Minimum Requirement then the Test Tolerance applied for this test is non-zero. The Test Tolerance for this test is defined in clause F.2 and the explanation of how the Minimum Requirement has been relaxed by the Test Tolerance is given in clause F.4. 8.7.3.1A Intra frequency measurement accuracy for 1,28 Mcps TDD Option 8.7.3.1A.1 Absolute accuracy requirement 8.7.3.1A.1.1 Definition and applicability The absolute accuracy of Timeslot ISCP is defined as the Timeslot ISCP meaasured from one cell / timeslot combination compared to the actual Timeslot ISCP level for the same cell / timeslot combination. The requirements and this test apply to all types of UTRA TDD UE. 8.7.3.1A.1.2 Minimum Requirements The absolute accuracy requirements in table 8.7.3.1A.1.1 are valid under the following conditions: P-CCPCH RSCP  -102 dBm. Table 8.7.3.1A.1.1: UE TDD Timeslot ISCP intra frequency absolute accuracy (1,28 Mcps option) Parameter Unit Accuracy [dB] Conditions Normal condition Extreme condition Io [dBm/ 1.28MHz] Timeslot_ISCP dBm  6  9 -94...-70 dBm  8  11 -70...-50 The normative reference for this requirement is TS 25.123 [2] clauses 9.2.1.2.1.2 8.7.3.1A.1.3 Test Purpose The purpose of this test is to verify that the Timeslot ISCP measurement accuracy is within the specified limits. 8.7.3.1A.1.4 Method of test 8.7.3.1A.1.4.1 Initial conditions Test environment: normal, TL/VL, TL/VH, TH/VL, TH/VH; see clauses G.2.1 and G.2.2. Frequencies to be tested: mid range; see clause G.2.4. In this case all cells are on the same frequency. Cell 1 and cell 2 shall be synchronised, i.e. share the same frame and timeslot timing. The Timeslot ISCP intra frequency absolute accuracy requirements are tested by using test parameters in table 8.7.3.1A.1.2. Table 8.7.3.1A.1.2: Timeslot ISCP intra frequency test parameters Test 1 Parameter Unit Cell 1 Cell 2 Timeslot Number 0 DwPTS 0 DwPTS UTRA RF Channel Number Channel 1 Channel 1 PCCPCH_Ec/Ior dB -3 -3 DwPCH_Ec/Ior dB 0 0 OCNS_Ec/Ior dB -3 -3 dB 5 2 dBm/1.28 MHz -76.6 TS ISCP, Note 1 dBm -74.6 -71.6 Io, Note 1 dBm/1.28 MHz -69 Propagation condition AWGN Test 2 Parameter Unit Cell 1 Cell 2 Timeslot Number 0 DwPTS 0 DwPTS UTRA RF Channel Number Channel 1 Channel 1 PCCPCH_Ec/Ior dB -3 -3 DwPCH_Ec/Ior dB 0 0 OCNS_Ec/Ior dB -3 -3 dB 9 2 dBm/1.28 MHz -60.2 TS ISCP, Note 1 dBm -58.2 -51.2 Io, Note 1 dBm/1.28 MHz -50 Propagation condition AWGN Test 3 Parameter Unit Cell 1 Cell 2 Timeslot Number 0 DwPTS 0 DwPTS UTRA RF Channel Number Channel 1 Channel 1 PCCPCH_Ec/Ior dB -3 -3 DwPCH_Ec/Ior dB 0 0 OCNS_Ec/Ior dB -3 -3 dB 5 3 dBm/1.28 MHz -101.9 TS ISCP, Note 1 dBm -98.9 -96.9 Io, Note 1 dBm/1.28 MHz -94 Propagation condition AWGN NOTE 1: TS ISCP and Io levels have been calculated from other parameters for information purposes. They are not settable parameters themselves. 1) A call is set up according to the test procedure specified in TS 34.108 [3] clause 7.3.2.3. The RF parameters for Test 1 are set up according to table 8.7.3.1A.1.2. 8.7.3.1A.1.4.2 Procedure 1) SS shall transmit MEASUREMENT CONTROL message. 2) UE shall transmit periodically MEASUREMENT REPORT messages. 3) SS shall check Timeslot ISCP values for Cell 1 / Timeslot 0 and Cell 2 / Timeslot 0 combinations in MEASUREMENT REPORT messages. These Timeslot ISCP values reported by the UE are compared to the actual Timeslot ISCP levels for each MEASUREMENT REPORT message. 4) SS shall count number of MEASUREMENT REPORT messages transmitted by UE. After 1000 MEASUREMENT REPORT messages have been received from UE, the RF parameters are set up according to table 8.7.3.1.1.2 for Test 2. While RF parameters are being set up, MEASUREMENT REPORT messages from UE are ignored. SS shall wait for additional 1s and ignore the MEASUREMENT REPORT messages during this period. Then, steps 2) and 3) above are repeated. After further 1000 MEASUREMENT REPORT messages have been received from UE, the RF parameters are set up according to table 8.7.3.1A.1.2 for Test 3. While RF parameters are being set up, MEASUREMENT REPORT messages from UE are ignored. SS shall wait for additional 1s and ignore the MEASUREMENT REPORT messages during this period. Then, steps 2) and 3) above are repeated. 5) After further 1000 MEASUREMENT REPORT messages have been received from UE, the SS shall transmit RRC CONNECTION RELEASE message. 6) UE shall transmit RRC CONNECTION RELEASE COMPLETE message. Specific Message Contents All messages indicated above shall use the same content as described in the default message content in clause 9 of 34.108 [3], with the following exceptions: MEASUREMENT CONTROL message (Step 1): Information Element/Group name Value/Remark Message Type (10.2.17) UE information elements -RRC transaction identifier 0 -Integrity check info Not Present Measurement Information elements -Measurement Identity 1 -Measurement Command (10.3.7.46) Modify -Measurement Reporting Mode (10.3.7.49) -Measurement Report Transfer Mode AM RLC -Periodical Reporting / Event Trigger Reporting Mode Periodical reporting -Additional measurements list (10.3.7.1) Not Present -CHOICE Measurement type Intra-frequency measurement -Intra-frequency measurement (10.3.7.36) -Intra-frequency measurement objects list (10.3.7.33) -CHOICE Intra-frequency cell removal Not present -New intra-frequency cells 2 -Intra-frequency cell id 1 -Cell info -Cell individual offset 0 -Reference time difference to cell Not present -Read SFN indicator FALSE -CHOICE mode TDD -Primary CCPCH info (10.3.6.57) -CHOICE mode TDD -CHOICE TDD option 1,28 Mcps TDD -Timeslot 0 -Cell parameters ID Set to cell parameter ID of cell 1 -SCTD indicator FALSE -Primary CCPCH Tx power Set to Primary CCPCH Tx power of cell 1 as described in Table 8.7.3.1A.2. -Timeslot number 0 -Burst type 1 -Intra-frequency cell id 2 -Cell info -Cell individual offset 0 -Reference time difference to cell Not present -Read SFN indicator FALSE -CHOICE mode TDD -Primary CCPCH info (10.3.6.57) -CHOICE mode TDD -CHOICE TDD option 1,28 Mcps TDD -Timeslot 0 -Cell parameters ID Set to cell parameter ID of cell 2 -SCTD indicator FALSE -Primary CCPCH Tx power Set to Primary CCPCH Tx power of cell 2 as described in Table 8.7.3.1A.2. -Timeslot number 0 -Burst type 1 -Intra-frequency measurement quantity (10.3.7.38) -Filter coefficient (10.3.7.9) 0 -CHOICE mode TDD -Measurement quantity list 1 -Measurement quantity Timeslot ISCP -Intra-frequency reporting quantity (10.3.7.41) -Reporting quantities for active set cells (10.3.7.5) -SFN-SFN observed time difference reporting indicator No report -Cell synchronisation information reporting indicator FALSE -Cell Identity reporting indicator FALSE -CHOICE mode TDD -Timeslot ISCP reporting indicator TRUE -Primary CCPCH RSCP reporting indicator TRUE -Pathloss reporting indicator FALSE -Reporting quantities for monitored set cells (10.3.7.5) -SFN-SFN observed time difference reporting indicator No report -Cell synchronisation information reporting indicator FALSE -Cell Identity reporting indicator FALSE -CHOICE mode TDD -Timeslot ISCP reporting indicator TRUE -Proposed TGSN reporting required FALSE -Primary CCPCH RSCP reporting indicator TRUE -Pathloss reporting indicator FALSE -Reporting quantities for detected set cells (10.3.7.5) Not Present -Reporting cell status (10.3.7.61) -CHOICE reported cell Report all active set cells + cells within monitored set on used frequency -Maximum number of reported cells Virtual / active set cells + 1 -Measurement validity (10.3.7.51) Not Present -CHOICE report criteria (10.3.7. -Periodical reporting criteria (10.3.7.53) -Amount of reporting Infinity -Reporting interval 500 ms Physical channel information elements -DPCH compressed mode status info (10.3.6.34) Not Present 8.7.3.1A.1.5 Test requirements The Timeslot ISCP measurement accuracy shall meet the requirements in clause 8.7.3.1A.1.2 for at least 900 of the reported Timeslot ISCP levels at each input level in step 4 for both Cell 1 / Timeslot 0 and Cell 2 / Timeslot 0 combinations. NOTE: If the above Test Requirement differs from the Minimum Requirement then the Test Tolerance applied for this test is non-zero. The Test Tolerance for this test is defined in clause F.2 and the explanation of how the Minimum Requirement has been relaxed by the Test Tolerance is given in clause F.4. 8.7.3.1B Intra frequency measurement accuracy for 7,68 Mcps TDD Option 8.7.3.1B.1 Absolute accuracy requirement 8.7.3.1B.1.1 Definition and applicability The absolute accuracy of Timeslot ISCP is defined as the Timeslot ISCP meaasured from one cell / timeslot combination compared to the actual Timeslot ISCP level for the same cell / timeslot combination. The requirements and this test apply to all types of UTRA TDD UE. 8.7.3.1B.1.2 Minimum Requirements The absolute accuracy requirements in table 8.7.3.1B.1.2.1 are valid under the following conditions: P-CCPCH RSCP  -102 dBm. Table 8.7.3.1B.1.2.1: UE Timeslot ISCP intra frequency absolute accuracy (7,68Mcps option) Parameter Unit Accuracy [dB] Conditions Normal condition Extreme condition Io [dBm/ 7.68 MHz] Timeslot_ISCP dBm  6  9 -94...-70 dBm  8  11 -70...-50 The normative reference for this requirement is TS 25.123 [2] clauses 9.1.1.3.1.3. and A.9.3.3. 8.7.3.1B.1.3 Test Purpose The purpose of this test is to verify that the Timeslot ISCP measurement accuracy is within the specified limits. 8.7.3.1B.1.4 Method of test 8.7.3.1B.1.4.1 Initial conditions Test environment: normal, TL/VL, TL/VH, TH/VL, TH/VH; see clauses G.2.1 and G.2.2. Frequencies to be tested: mid range; see clause G.2.4. In this case all cells are on the same frequency. Cell 1 and cell 2 shall be synchronised, i.e. share the same frame and timeslot timing. The DL DPCH shall be transmitted in timeslot 4 and the UL DPCH shall be transmitted in timeslot 12. The second Beacon timeslot shall be provided in timeslot 8 for both cell 1 and cell 2. The Timeslot ISCP intra frequency absolute accuracy requirements are tested by using test parameters in table 8.7.3.1B.1.4.1.1. Table 8.7.3.1B.1.4.1.1: Timeslot ISCP intra frequency test parameters Parameter Unit Test 1 Test 2 Test 3 Cell 1 Cell 2 Cell 1 Cell 2 Cell 1 Cell 2 DL timeslot number 0 0 0 0 0 0 UTRA RF Channel number Channel 1 Channel 1 Channel 1 PCCPCH_Ec/Ior dB -3 -3 -3 SCH_Ec/Ior dB -9 -9 -9 SCH_toffset 0 5 0 5 0 5 OCNS_Ec/Ior dB -3,12 -3,12 -3,12 Ioc dBm / 7.68 MHz -75.7 -59.8 -98.7 Îor/Ioc dB 5 2 9 2 3 0 Timeslot ISCP, Note 1 dBm -73.7 -70.7 -57.8 -50.8 -98.7 -95.7 Io, Note 1 dBm / 7.68 MHz -69 -50 -94 Propagation condition AWGN AWGN AWGN NOTE 1: Timeslot ISCP and Io levels have been calculated from other parameters for information purposes. They are not settable parameters themselves. 1) A call is set up according to the test procedure specified in TS 34.108 [3] clause 7.3.2.3. The RF parameters for Test 1 are set up according to table 8.7.3.1B.1.4.1.1. 8.7.3.1B.1.4.2 Procedure 1) SS shall transmit MEASUREMENT CONTROL message. 2) UE shall transmit periodically MEASUREMENT REPORT messages. 3) SS shall check Timeslot ISCP values for Cell 1 / Timeslot 0 and Cell 2 / Timeslot 0 combinations in MEASUREMENT REPORT messages. These Timeslot ISCP values reported by the UE are compared to the actual Timeslot ISCP levels for each MEASUREMENT REPORT message. 4) SS shall count number of MEASUREMENT REPORT messages transmitted by UE. After 1000 MEASUREMENT REPORT messages have been received from UE, the RF parameters are set up according to table 8.7.3.1.1.2 for Test 2. While RF parameters are being set up, MEASUREMENT REPORT messages from UE are ignored. SS shall wait for additional 1s and ignore the MEASUREMENT REPORT messages during this period. Then, steps 2) and 3) above are repeated. After further 1000 MEASUREMENT REPORT messages have been received from UE, the RF parameters are set up according to table 8.7.3.1.1.2 for Test 3. While RF parameters are being set up, MEASUREMENT REPORT messages from UE are ignored. SS shall wait for additional 1s and ignore the MEASUREMENT REPORT messages during this period. Then, steps 2) and 3) above are repeated. 5) After further 1000 MEASUREMENT REPORT messages have been received from UE, the SS shall transmit RRC CONNECTION RELEASE message. 6) UE shall transmit RRC CONNECTION RELEASE COMPLETE message. Specific Message Contents All messages indicated above shall use the same content as described in the default message content in clause 9 of 34.108 [3] and in Annex I, with the following exceptions: MEASUREMENT CONTROL message (Step 1): Information Element/Group name Value/Remark Message Type (10.2.17) UE information elements -RRC transaction identifier 0 -Integrity check info Not Present Measurement Information elements -Measurement Identity 1 -Measurement Command (10.3.7.46) Modify -Measurement Reporting Mode (10.3.7.49) -Measurement Report Transfer Mode AM RLC -Periodical Reporting / Event Trigger Reporting Mode Periodical reporting -Additional measurements list (10.3.7.1) Not Present -CHOICE Measurement type Intra-frequency measurement -Intra-frequency measurement (10.3.7.36) -Intra-frequency measurement objects list (10.3.7.33) -CHOICE Intra-frequency cell removal Not present -New intra-frequency cells 2 -Intra-frequency cell id 1 -Cell info -Cell individual offset 0 -Reference time difference to cell Not present -Read SFN indicator FALSE -CHOICE mode TDD -Primary CCPCH info (10.3.6.57) -CHOICE mode TDD -CHOICE TDD option 7,68 Mcps TDD -CHOICE Sync case 2 -Timeslot 0 -Cell parameters ID Set to cell parameter ID of cell 1 -SCTD indicator FALSE -Primary CCPCH Tx power Set to Primary CCPCH Tx power of cell 1 as described in Table 8.7.3.1.2. -Timeslot number 0 -Burst type 1 -Intra-frequency cell id 2 -Cell info -Cell individual offset 0 -Reference time difference to cell Not present -Read SFN indicator FALSE -CHOICE mode TDD -Primary CCPCH info (10.3.6.57) -CHOICE mode TDD -CHOICE TDD option 7,68 Mcps TDD -CHOICE Sync case 2 -Timeslot 0 -Cell parameters ID Set to cell parameter ID of cell 2 -SCTD indicator FALSE -Primary CCPCH Tx power Set to Primary CCPCH Tx power of cell 2 as described in Table 8.7.3.1.2. -Timeslot number 0 -Burst type 1 -Intra-frequency measurement quantity (10.3.7.38) -Filter coefficient (10.3.7.9) 0 -CHOICE mode TDD -Measurement quantity list 1 -Measurement quantity Timeslot ISCP -Intra-frequency reporting quantity (10.3.7.41) -Reporting quantities for active set cells (10.3.7.5) -SFN-SFN observed time difference reporting indicator No report -Cell synchronisation information reporting indicator FALSE -Cell Identity reporting indicator FALSE -CHOICE mode TDD -Timeslot ISCP reporting indicator TRUE -Primary CCPCH RSCP reporting indicator TRUE -Pathloss reporting indicator FALSE -Reporting quantities for monitored set cells (10.3.7.5) -SFN-SFN observed time difference reporting indicator No report -Cell synchronisation information reporting indicator FALSE -Cell Identity reporting indicator FALSE -CHOICE mode TDD -Timeslot ISCP reporting indicator TRUE -Proposed TGSN reporting required FALSE -Primary CCPCH RSCP reporting indicator TRUE -Pathloss reporting indicator FALSE -Reporting quantities for detected set cells (10.3.7.5) Not Present -Reporting cell status (10.3.7.61) -CHOICE reported cell Report all active set cells + cells within monitored set on used frequency -Maximum number of reported cells Virtual / active set cells + 1 -Measurement validity (10.3.7.51) Not Present -CHOICE report criteria (10.3.7. -Periodical reporting criteria (10.3.7.53) -Amount of reporting Infinity -Reporting interval 500 ms Physical channel information elements -DPCH compressed mode status info (10.3.6.34) Not Present 8.7.3.1B.1.5 Test requirements The Timeslot ISCP measurement accuracy shall meet the requirements in clause 8.7.3.1B.1.2 for at least 900 of the reported Timeslot ISCP levels at each input level in step 4 for both Cell 1 / Timeslot 0 and Cell 2 / Timeslot 0 combinations. NOTE: If the above Test Requirement differs from the Minimum Requirement then the Test Tolerance applied for this test is non-zero. The Test Tolerance for this test is defined in clause F.2 and the explanation of how the Minimum Requirement has been relaxed by the Test Tolerance is given in clause F.4.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.4 UTRA carrier RSSI
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.4.1 Absolute measurement accuracy for 3,84 Mcps TDD Option
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.4.1.1 Definition and applicability
The absolute accuracy of UTRA carrier RSSI is defined as the UTRA carrier RSSI measured from one frequency compared to the actual UTRA carrier RSSI power of that same frequency. The requirements and this test apply to all types of UTRA TDD UE.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.4.1.2 Minimum Requirements
Table 8.7.4.1.1: UTRA carrier RSSI inter frequency absolute accuracy Parameter Unit Accuracy [dB] Conditions Normal condition Extreme condition Io [dBm/ 3,84 MHz] UTRA carrier RSSI dBm  4  7 -94...-70 dBm  6  9 -70...-50 The normative reference for this requirement is TS 25.123 [2] clause 9.1.1.4.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.4.1.3 Test Purpose
The purpose of this test is to verify that the UTRA carrier RSSI measurement accuracy is within the specified limits.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.4.1.4 Method of test
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.4.1.4.1 Initial conditions
Test environment: normal, TL/VL, TL/VH, TH/VL, TH/VH; see clauses G.2.1 and G.2.2. Frequencies to be tested: mid range; see clause G.2.4. In this case both cells are on different frequencies. Cell 1 and cell 2 shall be synchronised, i.e. share the same frame and timeslot timing. The DL DPCH shall be transmitted in timeslot 4 and the UL DPCH shall be transmitted in timeslot 12. The second Beacon timeslot shall be provided in timeslot 8 for cell 1 and in timeslot 10 for cell 2. UTRA carrier RSSI absolute accuracy requirements are tested by using test parameters in table 8.7.4.1.2. Table 8.7.4.1.2: UTRA carrier RSSI inter frequency test parameters Parameter Unit Test 1 Test 2 Test 3 Cell 1 Cell 2 Cell 1 Cell 2 Cell 1 Cell 2 DL timeslot number 0 2 0 2 0 2 UTRA RF Channel number Channel 1 Channel 2 Channel 1 Channel 2 Channel 1 Channel 2 PCCPCH_Ec/Ior dB -3 -3 -3 SCH_Ec/Ior dB -9 -9 -9 SCH_toffset 0 5 0 5 0 5 OCNS_Ec/Ior dB -3,12 -3,12 -3,12 Ioc dBm / 3,84 MHz -75.2 -75.2 -57.8 -54.1 -98.7 -97 Îor/Ioc dB 5 5 7 2 3 0 Io, Note 1 dBm / 3,84 MHz -69 -50 -94 Propagation condition AWGN AWGN AWGN NOTE 1: Io levels have been calculated from other parameters for information purposes. They are not settable parameters themselves. 1) A call is set up according to the test procedure specified in TS 34.108 [3] subclause 7.3.2.3. The RF parameters for Test 1 are set up according to table 8.7.4.1.2.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.4.1.4.2 Procedure
1) SS shall transmit the MEASUREMENT CONTROL message for inter frequency measurements. 2) UE shall transmit periodically the MEASUREMENT REPORT messages. 3) SS shall check UTRA carrier RSSI value of Channel 2 in MEASUREMENT REPORT messages. UTRA carrier RSSI power of Channel 2 reported by UE is compared to actual UTRA carrier RSSI value of Channel 2 for each MEASUREMENT REPORT message. 4) SS shall count number of MEASUREMENT REPORT messages transmitted by UE. After 1000 MEASUREMENT REPORT messages have been received from UE, the RF parameters are set up according to table 8.7.4.1.2 for Test 2. While RF parameters are being set up, MEASUREMENT REPORT messages from UE are ignored. SS shall wait for additional 1s and ignore the MEASUREMENT REPORT messages during this period. Then, step 2) and 3) above are repeated. After further 1000 MEASUREMENT REPORT messages have been received from UE, the RF parameters are set up according to table 8.7.4.1.2 for Test 3. While RF parameters are being set up, MEASUREMENT REPORT messages from UE are ignored. SS shall wait for additional 1s and ignore the MEASUREMENT REPORT messages during this period. Then, steps 2) and 3) above are repeated. 5) After further 1000 MEASUREMENT REPORT messages have been received from UE, the SS shall transmit RRC CONNECTION RELEASE message. 6) UE shall transmit RRC CONNECTION RELEASE COMPLETE message. Specific Message Contents All messages indicated above shall use the same content as described in the default message content in clause 9 of 34.108 [3] and in Annex I, with the following exceptions: MEASUREMENT CONTROL message for inter frequency measurement (Step 1): Information Element/Group name Value/Remark Message Type (10.2.17) UE information elements -RRC transaction identifier 0 -Integrity check info Not Present Measurement Information elements -Measurement Identity 2 -Measurement Command (10.3.7.46) Setup -Measurement Reporting Mode (10.3.7.49) -Measurement Report Transfer Mode AM RLC -Periodical Reporting / Event Trigger Reporting Mode Periodical reporting -Additional measurements list (10.3.7.1) Not Present -CHOICE Measurement type Inter-frequency measurement -Inter-frequency measurement (10.3.7.16) -Inter-frequency measurement objects list (10.3.7.13) -CHOICE inter-frequency cell removal Not present -New inter-frequency cells Cell 2 information is included -Cell for measurement Not Present -Inter-frequency measurement quantity (10.3.7.18) -CHOICE reporting critera Inter-frequency reporting criteria -Filter coefficient (10.3.7.9) 0 -CHOICE mode TDD -Measurement quantity for frequency quality estimate Primary CCPCH RSCP -Inter-frequency reporting quantity (10.3.7.21) -UTRA carrier RSSI TRUE -Frequency quality estimate TRUE -Non frequency related cell reporting quantities (10.3.7.5) -SFN-SFN observed time difference reporting indicator No report -Cell synchronisation information reporting indicator FALSE -Cell identity reporting indicator FALSE -CHOICE mode TDD -Timeslot ISCP reporting indicator FALSE -Proposed TGSN Reporting required FALSE -Primary CCPCH RSCP reporting indicator TRUE -Pathloss reporting indicator FALSE -Reporting cell status (10.3.7.61) -CHOICE reported cell Report all active set cells + cells within monitored set on used frequency -Maximum number of reported cells Virtual/active set cells + 2 -Measurement validity (10.3.7.51) Not present -Inter-frequency set update Not present -CHOICE report criteria (10.3.7. -Periodical reporting criteria (10.3.7.53) -Amount of reporting Infinity -Reporting interval 500 ms Physical channel information elements -DPCH compressed mode status info (10.3.6.34) Not Present
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.4.1.5 Test requirements
The UTRA carrier RSSI absolute measurement accuracy shall meet the requirements in clause 8.7.4.1.2. The effect of assumed thermal noise and noise generated in the receiver (–99 dBm) shall be added into the required accuracy defined in subclause 8.7.4.1.2 as shown in table 8.7.4.1.3. Table 8.7.4.1.3: UTRA carrier RSSI absolute accuracy Parameter Unit Accuracy [dB] Conditions Normal condition Extreme condition Io [dBm/3,84 MHz] UTRA carrier RSSI dBm -4…5.2 -7…8.2 -94…-87 dBm  4  7 -87...-70 dBm  6  9 -70...-50 The normative reference for this requirement is TS 25.123 [2] clause A.9.1.4. NOTE: If the above Test Requirement differs from the Minimum Requirement then the Test Tolerance applied for this test is non-zero. The Test Tolerance for this test is defined in clause F.2 and the explanation of how the Minimum Requirement has been relaxed by the Test Tolerance is given in clause F.4. 8.7.4.1A Absolute measurement accuracy for 1,28 Mcps TDD Option 8.7.4.1A.1 Definition and applicability The absolute accuracy of UTRA carrier RSSI is defined as the UTRA carrier RSSI measured from one frequency compared to the actual UTRA carrier RSSI power of that same frequency. The requirements and this test apply to all types of UTRA TDD UE. 8.7.4.1A.2 Minimum Requirements Table 8.7.4.1A.1: 1,28Mcps UTRA carrier RSSI inter frequency absolute accuracy Parameter Unit Accuracy [dB] Conditions Normal condition Extreme condition Io [dBm/ 1,28 MHz] UTRA carrier RSSI dBm  4  7 -94...-70 dBm  6  9 -70...-50 The normative reference for this requirement is TS 25.123 [2] clause 9.1.1.4. 8.7.4.1A.3 Test Purpose The purpose of this test is to verify that the UTRA carrier RSSI measurement accuracy is within the specified limits. 8.7.4.1A.4 Method of test 8.7.4.1A.4.1 Initial conditions Test environment: normal, TL/VL, TL/VH, TH/VL, TH/VH; see clauses G.2.1 and G.2.2. Frequencies to be tested: mid range; see clause G.2.4. In this case both cells are on different frequencies. Cell 1 and cell 2 shall be synchronised, i.e. share the same frame and timeslot timing.. UTRA carrier RSSI absolute accuracy requirements are tested by using test parameters in table 8.7.4.1A.2. Table 8.7.4.1A.2: 1,28Mcps UTRA carrier RSSI inter frequency test parameters Test 1 Parameter Unit Cell 1 Cell 2 Timeslot Number 0 DwPTS 0 DwPTS UTRA RF Channel Number Channel 1 Channel 2 PCCPCH_Ec/Ior dB -3 -3 DwPCH_Ec/Ior dB 0 0 OCNS_Ec/Ior dB -3 -3 dB 5 5 dBm/1.28 MHz -75.2 -75.2 Io, Note 1 dBm/1.28 MHz -69 Propagation condition AWGN Test 2 Parameter Unit Cell 1 Cell 2 Timeslot Number 0 DwPTS 0 DwPTS UTRA RF Channel Number Channel 1 Channel 2 PCCPCH_Ec/Ior dB -3 -3 DwPCH_Ec/Ior dB 0 0 OCNS_Ec/Ior dB -3 -3 dB 7 2 dBm/1.28 MHz -57.8 -54.1 Io, Note 1 dBm/1.28 MHz -50 Propagation condition AWGN Test 3 Parameter Unit Cell 1 Cell 2 Timeslot Number 0 DwPTS 0 DwPTS UTRA RF Channel Number Channel 1 Channel 2 PCCPCH_Ec/Ior dB -3 -3 DwPCH_Ec/Ior dB 0 0 OCNS_Ec/Ior dB -3 -3 dB 3 0 dBm/1.28 MHz -98.7 -97 Io, Note 1 dBm/1.28 MHz -94 Propagation condition AWGN NOTE 1: Io levels have been calculated from other parameters for information purposes. They are not settable parameters themselves. 1) A call is set up according to the test procedure specified in TS 34.108 [3] subclause 7.3.2.3. The RF parameters for Test 1 are set up according to table 8.7.4.1A.2. 8.7.4.1A.4.2 Procedure 1) SS shall transmit the MEASUREMENT CONTROL message for inter frequency measurements. 2) UE shall transmit periodically the MEASUREMENT REPORT messages. 3) SS shall check UTRA carrier RSSI value of Channel 2 in MEASUREMENT REPORT messages. UTRA carrier RSSI power of Channel 2 reported by UE is compared to actual UTRA carrier RSSI value of Channel 2 for each MEASUREMENT REPORT message. 4) SS shall count number of MEASUREMENT REPORT messages transmitted by UE. 5) After 1000 MEASUREMENT REPORT messages have been received from UE, the RF parameters are set up according to table 8.7.4.1A.2 for Test 2. While RF parameters are being set up, MEASUREMENT REPORT messages from UE are ignored. SS shall wait for additional 1s and ignore the MEASUREMENT REPORT messages during this period. Then, step 2) and 3) above are repeated. 6) After further 1000 MEASUREMENT REPORT messages have been received from UE, the RF parameters are set up according to table 8.7.4.1A.2 for Test 3. While RF parameters are being set up, MEASUREMENT REPORT messages from UE are ignored. SS shall wait for additional 1s and ignore the MEASUREMENT REPORT messages during this period. Then, steps 2) and 3) above are repeated. 7) After further 1000 MEASUREMENT REPORT messages have been received from UE, the SS shall transmit RRC CONNECTION RELEASE message. 8) UE shall transmit RRC CONNECTION RELEASE COMPLETE message. Specific Message Contents All messages indicated above shall use the same content as described in the default message content in clause 9 of 34.108 [3] MEASUREMENT CONTROL message for inter frequency measurement (Step 1): Information Element/Group name Value/Remark Message Type (10.2.17) UE information elements -RRC transaction identifier 0 -Integrity check info Not Present Measurement Information elements -Measurement Identity 2 -Measurement Command (10.3.7.46) Setup -Measurement Reporting Mode (10.3.7.49) -Measurement Report Transfer Mode AM RLC -Periodical Reporting / Event Trigger Reporting Mode Periodical reporting -Additional measurements list (10.3.7.1) Not Present -CHOICE Measurement type Inter-frequency measurement -Inter-frequency measurement (10.3.7.16) -Inter-frequency measurement objects list (10.3.7.13) -CHOICE inter-frequency cell removal Not present -New inter-frequency cells Cell 2 information is included -Cell for measurement Not Present -Inter-frequency measurement quantity (10.3.7.18) -CHOICE reporting critera Inter-frequency reporting criteria -Filter coefficient (10.3.7.9) 0 -CHOICE mode TDD -Measurement quantity for frequency quality estimate Primary CCPCH RSCP -Inter-frequency reporting quantity (10.3.7.21) -UTRA carrier RSSI TRUE -Frequency quality estimate TRUE -Non frequency related cell reporting quantities (10.3.7.5) -SFN-SFN observed time difference reporting indicator No report -Cell synchronisation information reporting indicator FALSE -Cell identity reporting indicator FALSE -CHOICE mode TDD -Timeslot ISCP reporting indicator FALSE -Proposed TGSN Reporting required FALSE -Primary CCPCH RSCP reporting indicator TRUE -Pathloss reporting indicator FALSE -Reporting cell status (10.3.7.61) -CHOICE reported cell Report all active set cells + cells within monitored set on used frequency -Maximum number of reported cells Virtual/active set cells + 2 -Measurement validity (10.3.7.51) Not present -Inter-frequency set update Not present -CHOICE report criteria (10.3.7. -Periodical reporting criteria (10.3.7.53) -Amount of reporting Infinity -Reporting interval 500 ms Physical channel information elements -DPCH compressed mode status info (10.3.6.34) Not Present 8.7.4.1A.5 Test requirements The UTRA carrier RSSI absolute measurement accuracy shall meet the requirements in clause 8.7.4.1A.2 for at least 900 of the reported RSSI levels at each input level. The effect of assumed thermal noise and noise generated in the receiver (–99 dBm) shall be added into the required accuracy defined in subclause 8.7.4.1A.2 as shown in table 8.7.4.1A.3. (only relevent for the lowest power test 3) Table 8.7.4.1A.3: 1,28Mcps UTRA carrier RSSI absolute accuracy (corrected for RX noise) Parameter Unit Accuracy [dB] Conditions Normal condition Extreme condition Io [dBm/1,28 MHz] UTRA carrier RSSI dBm -4…5.2 -7…8.2 -94…-87 dBm  4  7 -87...-70 dBm  6  9 -70...-50 The normative reference for this requirement is TS 25.123 [2] clause A.9.1.4. NOTE: If the above Test Requirement differs from the Minimum Requirement then the Test Tolerance applied for this test is non-zero. The Test Tolerance for this test is defined in clause F.2 and the explanation of how the Minimum Requirement has been relaxed by the Test Tolerance is given in clause F.4. 8.7.4.1B Absolute measurement accuracy for 7,68 Mcps TDD Option 8.7.4.1B.1 Definition and applicability The absolute accuracy of UTRA carrier RSSI is defined as the UTRA carrier RSSI measured from one frequency compared to the actual UTRA carrier RSSI power of that same frequency. The requirements and this test apply to all types of UTRA TDD UE. 8.7.4.1B.2 Minimum Requirements Table 8.7.4.1B.2.1: UTRA carrier RSSI inter frequency absolute accuracy Parameter Unit Accuracy [dB] Conditions Normal condition Extreme condition Io [dBm/ 7.68 MHz] UTRA Carrier RSSI dBm  4  7 -94...-70 dBm  6  9 -70...-50 The normative reference for this requirement is TS 25.123 [2] clause 9.1.1.4.1.3 and A9.3.4 8.7.4.1B.3 Test Purpose The purpose of this test is to verify that the UTRA carrier RSSI measurement accuracy is within the specified limits. 8.7.4.1B.4 Method of test 8.7.4.1B.4.1 Initial conditions Test environment: normal, TL/VL, TL/VH, TH/VL, TH/VH; see clauses G.2.1 and G.2.2. Frequencies to be tested: mid range; see clause G.2.4. In this case both cells are on different frequencies. Cell 1 and cell 2 shall be synchronised, i.e. share the same frame and timeslot timing. The DL DPCH shall be transmitted in timeslot 4 and the UL DPCH shall be transmitted in timeslot 12. The second Beacon timeslot shall be provided in timeslot 8 for cell 1 and in timeslot 10 for cell 2. UTRA carrier RSSI absolute accuracy requirements are tested by using test parameters in table 8.7.4.1B.4.1.1. Table 8.7.4.1B.4.1.1: UTRA carrier RSSI inter frequency test parameters Parameter Unit Test 1 Test 2 Test 3 Cell 1 Cell 2 Cell 1 Cell 2 Cell 1 Cell 2 DL timeslot number 0 2 0 2 0 2 UTRA RF Channel number Channel 1 Channel 2 Channel 1 Channel 2 Channel 1 Channel 2 PCCPCH_Ec/Ior dB -3 -3 -3 SCH_Ec/Ior dB -9 -9 -9 SCH_toffset 0 5 0 5 0 5 OCNS_Ec/Ior dB -3,12 -3,12 -3,12 Ioc dBm / 7.68 MHz -75.2 -75.2 -57.8 -54.1 -98.7 -97 Îor/Ioc dB 5 5 7 2 3 0 Io, Note 1 dBm / 7.68 MHz -69 -50 -94 Propagation condition AWGN AWGN AWGN NOTE 1: Io levels have been calculated from other parameters for information purposes. They are not settable parameters themselves. 1) A call is set up according to the test procedure specified in TS 34.108 [3] subclause 7.3.2.3. The RF parameters for Test 1 are set up according to table 8.7.4.1B.4.1.1. 8.7.4.1B.4.2 Procedure 1) SS shall transmit the MEASUREMENT CONTROL message for inter frequency measurements. 2) UE shall transmit periodically the MEASUREMENT REPORT messages. 3) SS shall check UTRA carrier RSSI value of Channel 2 in MEASUREMENT REPORT messages. UTRA carrier RSSI power of Channel 2 reported by UE is compared to actual UTRA carrier RSSI value of Channel 2 for each MEASUREMENT REPORT message. 4) SS shall count number of MEASUREMENT REPORT messages transmitted by UE. After 1000 MEASUREMENT REPORT messages have been received from UE, the RF parameters are set up according to table 8.7.4.1B.4.1.1 for Test 2. While RF parameters are being set up, MEASUREMENT REPORT messages from UE are ignored. SS shall wait for additional 1s and ignore the MEASUREMENT REPORT messages during this period. Then, step 2) and 3) above are repeated. After further 1000 MEASUREMENT REPORT messages have been received from UE, the RF parameters are set up according to table 8.7.4.1B.4.1.1 for Test 3. While RF parameters are being set up, MEASUREMENT REPORT messages from UE are ignored. SS shall wait for additional 1s and ignore the MEASUREMENT REPORT messages during this period. Then, steps 2) and 3) above are repeated. 5) After further 1000 MEASUREMENT REPORT messages have been received from UE, the SS shall transmit RRC CONNECTION RELEASE message. 6) UE shall transmit RRC CONNECTION RELEASE COMPLETE message. Specific Message Contents All messages indicated above shall use the same content as described in the default message content in clause 9 of 34.108 [3] and in Annex I, with the following exceptions: MEASUREMENT CONTROL message for inter frequency measurement (Step 1): Information Element/Group name Value/Remark Message Type (10.2.17) UE information elements -RRC transaction identifier 0 -Integrity check info Not Present Measurement Information elements -Measurement Identity 2 -Measurement Command (10.3.7.46) Setup -Measurement Reporting Mode (10.3.7.49) -Measurement Report Transfer Mode AM RLC -Periodical Reporting / Event Trigger Reporting Mode Periodical reporting -Additional measurements list (10.3.7.1) Not Present -CHOICE Measurement type Inter-frequency measurement -Inter-frequency measurement (10.3.7.16) -Inter-frequency measurement objects list (10.3.7.13) -CHOICE inter-frequency cell removal Not present -New inter-frequency cells Cell 2 information is included -Cell for measurement Not Present -Inter-frequency measurement quantity (10.3.7.18) -CHOICE reporting critera Inter-frequency reporting criteria -Filter coefficient (10.3.7.9) 0 -CHOICE mode TDD -Measurement quantity for frequency quality estimate Primary CCPCH RSCP -Inter-frequency reporting quantity (10.3.7.21) -UTRA carrier RSSI TRUE -Frequency quality estimate TRUE -Non frequency related cell reporting quantities (10.3.7.5) -SFN-SFN observed time difference reporting indicator No report -Cell synchronisation information reporting indicator FALSE -Cell identity reporting indicator FALSE -CHOICE mode TDD -Timeslot ISCP reporting indicator FALSE -Proposed TGSN Reporting required FALSE -Primary CCPCH RSCP reporting indicator TRUE -Pathloss reporting indicator FALSE -Reporting cell status (10.3.7.61) -CHOICE reported cell Report all active set cells + cells within monitored set on used frequency -Maximum number of reported cells Virtual/active set cells + 2 -Measurement validity (10.3.7.51) Not present -Inter-frequency set update Not present -CHOICE report criteria (10.3.7. -Periodical reporting criteria (10.3.7.53) -Amount of reporting Infinity -Reporting interval 500 ms Physical channel information elements -DPCH compressed mode status info (10.3.6.34) Not Present 8.7.4.1B.5 Test requirements The UTRA carrier RSSI absolute measurement accuracy shall meet the requirements in clause 8.7.4.1B.2. The effect of assumed thermal noise and noise generated in the receiver (–99 dBm) shall be added into the required accuracy defined in subclause 8.7.4.1B.2 as shown in table 8.7.4.1B.3. Table 8.7.4.1B.5.1: UTRA carrier RSSI absolute accuracy Parameter Unit Accuracy [dB] Conditions Normal condition Extreme condition Io [dBm/7.68 MHz] UTRA Carrier RSSI dBm -4…5.2 -7…8.2 -94…-87 dBm  4  7 -87...-70 dBm  6  9 -70...-50 The normative reference for this requirement is TS 25.123 [2] clause A.9.3.4. NOTE: If the above Test Requirement differs from the Minimum Requirement then the Test Tolerance applied for this test is non-zero. The Test Tolerance for this test is defined in clause F.2 and the explanation of how the Minimum Requirement has been relaxed by the Test Tolerance is given in clause F.4.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.4.2 Relative measurement accuracy for 3,84 Mcps TDD Option
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.4.2.1 Definition and applicability
The relative accuracy requirement is defined as the UTRA carrier RSSI measured from one frequency compared to the UTRA Carrier RSSI measured from another frequency. The requirements and this test apply to all types of UTRA TDD UE.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.4.2.2 Minimum Requirements
The accuracy requirements in table 8.7.4.2.1 are valid under the following condition: | Channel 1_Io|dBm/3,84 MHz ‑Channel 2_Io|dBm/3,84 MHz | < 20 dB. Table 8.7.4.2.1: UTRA carrier RSSI inter frequency relative accuracy Parameter Unit Accuracy [dB] Conditions Normal condition Extreme condition Io [dBm/3,84 MHz] UTRA carrier RSSI dBm  7  11 -94...-50 The normative reference for this requirement is TS 25.123 [2] clause 9.1.1.4.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.4.2.3 Test Purpose
The purpose of this test is to verify that the UTRA carrier RSSI measurement accuracy is within the specified limits.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.4.2.4 Method of test
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.4.2.4.1 Initial conditions
Test environment: normal, TL/VL, TL/VH, TH/VL, TH/VH; see clauses G.2.1 and G.2.2. Frequencies to be tested: mid range; see clause G.2.4. In this case both cells are on different frequencies. Cell 1 and cell 2 shall be synchronised, i.e. share the same frame and timeslot timing. The DL DPCH shall be transmitted in timeslot 4 and the UL DPCH shall be transmitted in timeslot 12. The second Beacon timeslot shall be provided in timeslot 8 for cell 1 and in timeslot 10 for cell 2. UTRA carrier RSSI absolute accuracy requirements are tested by using test parameters in table 8.7.4.1.2. 1) A call is set up according to the test procedure specified in TS 34.108 [3] clause 7.3.2.3. The RF parameters for Test 1 are set up according to table 8.7.4.1.2.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.4.2.4.2 Procedure
1) SS shall transmit the MEASUREMENT CONTROL message for Inter-frequency measurements. 2) UE shall transmit periodically the MEASUREMENT REPORT messages. 3) SS shall check UTRA carrier RSSI value of Channel 2 in MEASUREMENT REPORT messages. UTRA carrier RSSI power of Channel 2 reported by UE is compared to actual UTRA carrier RSSI value of Channel 2 for each MEASUREMENT REPORT message. 4) SS shall count number of MEASUREMENT REPORT messages transmitted by UE. After 1000 MEASUREMENT REPORT messages have been received from UE, the RF parameters are set up according to table 8.7.4.1.2 for Test 2. While RF parameters are being set up, MEASUREMENT REPORT messages from UE are ignored. SS shall wait for additional 1s and ignore the MEASUREMENT REPORT messages during this period. Then, step 3) above is repeated. After further 1000 MEASUREMENT REPORT messages have been received from UE, the RF parameters are set up according to table 8.7.4.1.2 for Test 3. While RF parameters are being set up, MEASUREMENT REPORT messages from UE are ignored. SS shall wait for additional 1s and ignore the MEASUREMENT REPORT messages during this period. Then, step 3) above is repeated. 5) After further 1000 MEASUREMENT REPORT messages have been received from UE, the SS shall transmit RRC CONNECTION RELEASE message. 6) UE shall transmit RRC CONNECTION RELEASE COMPLETE message. Specific Message Contents All messages indicated above shall use the same content as described in the default message content in clause 9 of 34.108 [3] and in Annex I, with the following exceptions: MEASUREMENT CONTROL message for inter frequency measurements in clause 8.7.4.1.4.2 is used.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.4.2.5 Test requirements
The UTRA carrier RSSI absolute measurement accuracy shall meet the requirements in clause 8.7.4.2.2. The effect of assumed thermal noise and noise generated in the receiver (–99 dBm) shall be added into the required accuracy defined in subclause 8.7.4.2.2 as shown in table 8.7.4.2.2. Table 8.7.4.2.2: UTRA carrier RSSI relative accuracy Parameter Unit Accuracy [dB] Conditions Normal condition Extreme condition Io [dBm/3,84 MHz] UTRA carrier RSSI dBm -4…5.2 -7…8.2 -94…-87 dBm  4  7 -87...-70 dBm  6  9 -70...-50 The normative reference for this requirement is TS 25.123 [2] clause A.9.1.4. NOTE: If the above Test Requirement differs from the Minimum Requirement then the Test Tolerance applied for this test is non-zero. The Test Tolerance for this test is defined in clause F.2 and the explanation of how the Minimum Requirement has been relaxed by the Test Tolerance is given in clause F.4. 8.7.4.2A Relative measurement accuracy for 1,28 Mcps TDD Option 8.7.4.2A.1 Definition and applicability The relative accuracy requirement is defined as the UTRA carrier RSSI measured from one frequency compared to the UTRA Carrier RSSI measured from another frequency. The requirements and this test apply to all types of UTRA TDD UE. 8.7.4.2A.2 Minimum Requirements The accuracy requirements in table 8.7.4.2A.1 are valid under the following condition: | Channel 1_Io|dBm/1.28 MHz ‑Channel 2_Io|dBm/1.28 MHz | < 20 dB. Table 8.7.4.2A.1: UTRA carrier RSSI inter frequency relative accuracy Parameter Unit Accuracy [dB] Conditions Normal condition Extreme condition Io [dBm/1,28 MHz] UTRA carrier RSSI dBm  7  11 -94...-50 The normative reference for this requirement is TS 25.123 [2] clause 9.1.1.4. 8.7.4.2A.3 Test Purpose The purpose of this test is to verify that the UTRA carrier RSSI measurement accuracy is within the specified limits. 8.7.4.2A.4 Method of test 8.7.4.2A.4.1 Initial conditions Test environment: normal, TL/VL, TL/VH, TH/VL, TH/VH; see clauses G.2.1 and G.2.2. Frequencies to be tested: mid range; see clause G.2.4. In this case both cells are on different frequencies. Cell 1 and cell 2 shall be synchronised, i.e. share the same frame and timeslot timing.. UTRA carrier RSSI absolute accuracy requirements are tested by using test parameters in table 8.7.4.1A.2. 1) A call is set up according to the test procedure specified in TS 34.108 [3] clause 7.3.2.3. The RF parameters for Test 1 are set up according to table 8.7.4.2A.2. Table 8.7.4.2A.2: 1,28Mcps UTRA carrier RSSI inter frequency test parameters Test 1 Parameter Unit Cell 1 Cell 2 Timeslot Number 0 DwPTS 0 DwPTS UTRA RF Channel Number Channel 1 Channel 2 PCCPCH_Ec/Ior dB -3 -3 DwPCH_Ec/Ior dB 0 0 OCNS_Ec/Ior dB -3 -3 dB 5 5 dBm/1.28 MHz -75.2 -75.2 Io, Note 1 dBm/1.28 MHz -69 Propagation condition AWGN Test 2 Parameter Unit Cell 1 Cell 2 Timeslot Number 0 DwPTS 0 DwPTS UTRA RF Channel Number Channel 1 Channel 2 PCCPCH_Ec/Ior dB -3 -3 DwPCH_Ec/Ior dB 0 0 OCNS_Ec/Ior dB -3 -3 dB 7 2 dBm/1.28 MHz -57.8 -54.1 Io, Note 1 dBm/1.28 MHz -50 Propagation condition AWGN Test 3 Parameter Unit Cell 1 Cell 2 Timeslot Number 0 DwPTS 0 DwPTS UTRA RF Channel Number Channel 1 Channel 2 PCCPCH_Ec/Ior dB -3 -3 DwPCH_Ec/Ior dB 0 0 OCNS_Ec/Ior dB -3 -3 dB 3 0 dBm/1.28 MHz -98.7 -97 Io, Note 1 dBm/1.28 MHz -94 Propagation condition AWGN NOTE 1: Io levels have been calculated from other parameters for information purposes. They are not settable parameters themselves. 8.7.4.2A.4.2 Procedure 1) SS shall transmit the MEASUREMENT CONTROL message for Inter-frequency measurements. 2) UE shall transmit periodically the MEASUREMENT REPORT messages. 3) SS shall check UTRA carrier RSSI value of Channel 2 in MEASUREMENT REPORT messages. UTRA carrier RSSI power of Channel 2 reported by UE is compared to actual UTRA carrier RSSI value of Channel 2 for each MEASUREMENT REPORT message. 4) SS shall count number of MEASUREMENT REPORT messages transmitted by UE. 5) After 1000 MEASUREMENT REPORT messages have been received from UE, the RF parameters are set up according to table 8.7.4.1.2 for Test 2. While RF parameters are being set up, MEASUREMENT REPORT messages from UE are ignored. SS shall wait for additional 1s and ignore the MEASUREMENT REPORT messages during this period. Then, step 3) above is repeated. 6) After further 1000 MEASUREMENT REPORT messages have been received from UE, the RF parameters are set up according to table 8.7.4.1.2 for Test 3. While RF parameters are being set up, MEASUREMENT REPORT messages from UE are ignored. SS shall wait for additional 1s and ignore the MEASUREMENT REPORT messages during this period. Then, step 3) above is repeated. 5) After further 1000 MEASUREMENT REPORT messages have been received from UE, the SS shall transmit RRC CONNECTION RELEASE message. 6) UE shall transmit RRC CONNECTION RELEASE COMPLETE message. Specific Message Contents All messages indicated above shall use the same content as described in the default message content in clause 9 of 34.108 [3] and in Annex I, with the following exceptions: The same MEASUREMENT CONTROL message for absolute inter frequency measurements in clause 8.7.4.1A.4.2 is used. 8.7.4.2A.5 Test requirements The UTRA carrier RSSI absolute measurement accuracy shall meet the requirements in clause 8.7.4.2A.2 for at least 900 of the reported RSSI levels at each input level. The effect of assumed thermal noise and noise generated in the receiver (–99 dBm) shall be added into the required accuracy defined in subclause 8.7.4.2A.2 as shown in table 8.7.4.2A.3. (only relevent for the lowest power test 3) Table 8.7.4.2A.3: UTRA carrier RSSI relative accuracy (corrected for RX noise) Parameter Unit Accuracy [dB] Conditions Normal condition Extreme condition Io [dBm/1,28 MHz] UTRA carrier RSSI dBm -4…5.2 -7…8.2 -94…-87 dBm  4  7 -87...-70 dBm  6  9 -70...-50 The normative reference for this requirement is TS 25.123 [2] clause A.9.1.4. NOTE: If the above Test Requirement differs from the Minimum Requirement then the Test Tolerance applied for this test is non-zero. The Test Tolerance for this test is defined in clause F.2 and the explanation of how the Minimum Requirement has been relaxed by the Test Tolerance is given in clause F.4. 8.7.4.2B Relative measurement accuracy for 7,68 Mcps TDD Option 8.7.4.2B.1 Definition and applicability The relative accuracy requirement is defined as the UTRA carrier RSSI measured from one frequency compared to the UTRA Carrier RSSI measured from another frequency. The requirements and this test apply to all types of UTRA TDD UE. 8.7.4.2B.2 Minimum Requirements The accuracy requirements in table 8.7.4.2B.2.1 are valid under the following condition: | Channel 1_Io|dBm/3,84 MHz ‑Channel 2_Io|dBm/3,84 MHz | < 20 dB. Table 8.7.4.2B.2.1: UTRA carrier RSSI inter frequency relative accuracy Parameter Unit Accuracy [dB] Conditions Normal condition Extreme condition Io [dBm/7.68 MHz] UTRA Carrier RSSI dBm  7  11 -94...-50 The normative reference for this requirement is TS 25.123 [2] clause 9.1.1.4.2 and A9.3.4 8.7.4.2B.3 Test Purpose The purpose of this test is to verify that the UTRA carrier RSSI measurement accuracy is within the specified limits. 8.7.4.2B.4 Method of test 8.7.4.2B.4.1 Initial conditions Test environment: normal, TL/VL, TL/VH, TH/VL, TH/VH; see clauses G.2.1 and G.2.2. Frequencies to be tested: mid range; see clause G.2.4. In this case both cells are on different frequencies. Cell 1 and cell 2 shall be synchronised, i.e. share the same frame and timeslot timing. The DL DPCH shall be transmitted in timeslot 4 and the UL DPCH shall be transmitted in timeslot 12. The second Beacon timeslot shall be provided in timeslot 8 for cell 1 and in timeslot 10 for cell 2. UTRA carrier RSSI absolute accuracy requirements are tested by using test parameters in table 8.7.4.1B.4.1.1. 1) A call is set up according to the test procedure specified in TS 34.108 [3] clause 7.3.2.3. The RF parameters for Test 1 are set up according to table 8.7.4.1B.4.1.1. 8.7.4.2B.4.2 Procedure 1) SS shall transmit the MEASUREMENT CONTROL message for Inter-frequency measurements. 2) UE shall transmit periodically the MEASUREMENT REPORT messages. 3) SS shall check UTRA carrier RSSI value of Channel 2 in MEASUREMENT REPORT messages. UTRA carrier RSSI power of Channel 2 reported by UE is compared to actual UTRA carrier RSSI value of Channel 2 for each MEASUREMENT REPORT message. 4) SS shall count number of MEASUREMENT REPORT messages transmitted by UE. After 1000 MEASUREMENT REPORT messages have been received from UE, the RF parameters are set up according to table 8.7.4.1B.4.1.1for Test 2. While RF parameters are being set up, MEASUREMENT REPORT messages from UE are ignored. SS shall wait for additional 1s and ignore the MEASUREMENT REPORT messages during this period. Then, step 3) above is repeated. After further 1000 MEASUREMENT REPORT messages have been received from UE, the RF parameters are set up according to table 8.7.4.1B.4.1.1 for Test 3. While RF parameters are being set up, MEASUREMENT REPORT messages from UE are ignored. SS shall wait for additional 1s and ignore the MEASUREMENT REPORT messages during this period. Then, step 3) above is repeated. 5) After further 1000 MEASUREMENT REPORT messages have been received from UE, the SS shall transmit RRC CONNECTION RELEASE message. 6) UE shall transmit RRC CONNECTION RELEASE COMPLETE message. Specific Message Contents All messages indicated above shall use the same content as described in the default message content in clause 9 of 34.108 [3] and in Annex I, with the following exceptions: MEASUREMENT CONTROL message for inter frequency measurements in clause 8.7.4.1B.4.2 is used. 8.7.4.2B.5 Test requirements The UTRA carrier RSSI absolute measurement accuracy shall meet the requirements in clause 8.7.4.2B.2. The effect of assumed thermal noise and noise generated in the receiver (–99 dBm) shall be added into the required accuracy defined in subclause 8.7.4.2B.2 as shown in table 8.7.4.2B.5.1. Table 8.7.4.2B.5.1: UTRA carrier RSSI relative accuracy Parameter Unit Accuracy [dB] Conditions Normal condition Extreme condition Io [dBm/3,84 MHz] UTRA carrier RSSI dBm -4…5.2 -7…8.2 -94…-87 dBm  4  7 -87...-70 dBm  6  9 -70...-50 The normative reference for this requirement is TS 25.123 [2] clause A.9.3.4. NOTE: If the above Test Requirement differs from the Minimum Requirement then the Test Tolerance applied for this test is non-zero. The Test Tolerance for this test is defined in clause F.2 and the explanation of how the Minimum Requirement has been relaxed by the Test Tolerance is given in clause F.4.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.5 GSM carrier RSSI
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.5.1.1 RSSI (RX_LEV) 3,84 Mcps TDD Option
Void 8.7.5.1A.1 RSSI (RX_LEV) 1,28 Mcps TDD Option 8.7.5.1A.1.1 Definition and applicability The absolute accuracy of GSM RSSI is defined as the RX_LEV measured in a GSM cell on one frequency compared to the actual power of that cell. The requirements and this test apply only to UE supporting both 1,28Mcps UTRA TDD and GSM. 8.7.5.1A.1.2 Minimum Requirements Table 8.7.5.1A.1.1: GSM RX_LEV absolute accuracy Parameter Unit Accuracy [dB] Conditions Normal condition Extreme condition Input level dBm RX_LEV dBm  4  6 -110…-70 dBm  6  6 -70…-48 dBm  9  9 -48..-38 RXLEV 0 = less than ‑110 dBm. RXLEV 1 = ‑110 dBm to ‑109 dBm RXLEV 2 = ‑109 dBm to ‑108 dBm : : RXLEV 62 = ‑49 dBm to ‑48 dBm RXLEV 63 = greater than ‑48 dBm The normative reference for this requirement is TS 45.008 [20] clause 8.1.2 8.7.5.1A.1.3 Test purpose The purpose of this test is to verify that the GSM RSSI absolute measurement accuracy is within the specified limits. This test will verify the requirements in section 9.1.1.5 and A.9.1.5 of TS25.123. 8.7.5.1A.1.4 Method of test 8.7.5.1A.1.4.1 Initial conditions Test environment: normal, TL/VL, TL/VH, TH/VL, TH/VH; see clauses G.2.1 and G.2.2. Frequencies to be tested: mid range; see clause G.2.4. Cell 1 is a UTRA 1,28Mcps TDD cell and cell 2 is a GSM cell A call is set up according to the test procedure specified in TS 34.108 [3] clause 7.3.2.3. The RF parameters for Test are set up according to table 8.7.5.1A.1.2. Table 8.7.5.1A.1.2. General GSM RSSI test parameters Parameter Unit Value Comment DCH parameters DL reference measurement channel 12.2 kbps As specified in TS 25.102 section A.2.2 Power Control On Target quality value on DTCH BLER 0.01 Inter-RAT measurement quantity GSM carrier RSSI BSIC verification required No Monitored cell list size 6 GSM neighbours including ARFCN 1 Table 8.7.5.1A.1.3 Cell 1 (TDD Cell) specific test parameters Parameter Unit Cell 1 DL timeslot number 0 DwPTS UTRA RF Channel number Channel 1 PCCPCH_Ec/Ior dB -3 DwPCH_Ec/Ior dB 0 OCNS_Ec/Ior dB -3 Îor/Ioc dB 3 Ioc dBm / 1.28MHz -70 Propagation condition AWGN Table 8.7.5.1A.1.4 Cell 2 specific GSM Cell test parameters Parameter Unit TEST1 TEST2 TEST3 UTRA RF Channel number 2 Cell Level dBm/200KHz -100 -75 -50 Propagation condition AWGN AWGN AWGN 8.7.5.1A.1.4.2 Procedure 1) SS shall transmit the MEASUREMENT CONTROL message for inter RAT measurement. In the measurement control information periodic reporting of the GSM carrier RSSI is requested to the UE. 2) UE shall transmit periodically MEASUREMENT REPORT messages. 3) SS shall check RX_LEV value of Cell 2 in the MEASUREMENT REPORT messages. Levels of Cell 2 reported by the UE are compared to the actual level of Cell 2 for each MEASUREMENT REPORT message. 4) SS shall count number of MEASUREMENT REPORT messages transmitted by UE. After 1000 MEASUREMENT REPORT messages have been received from UE, the GSM cell RF parameters are set up according to table 8.7.5.1A.1.4 for Test 2. While RF parameters are being set up, MEASUREMENT REPORT messages from UE are ignored. SS shall wait for additional 1s and ignore the MEASUREMENT REPORT messages during this period. Then, steps 2) and 3) above are repeated. 6) After further 1000 MEASUREMENT REPORT messages have been received from UE, the GSM cell RF parameters are set up according to table 8.7.5.1A.1.4 for Test 2. While RF parameters are being set up, MEASUREMENT REPORT messages from UE are ignored. SS shall wait for additional 1s and ignore the MEASUREMENT REPORT messages during this period. Then, steps 2) and 3) above are repeated. 7) After further 1000 MEASUREMENT REPORT messages have been received from UE, the SS shall transmit RRC CONNECTION RELEASE message. 8) UE shall transmit RRC CONNECTION RELEASE COMPLETE message. Specific Message Contents All messages indicated above shall use the same content as described in the default message content in clause 9 of 34.108 [3], with the following exceptions: Note: Numbers in brackets after an item e.g “Message Type (10.2.17)” in the IE description are references to clause numbers in TS 25.331 [9] describing that item in more detail. MEASUREMENT CONTROL message for GSM RSSI measurement (Step 1): Information Element Value/Remark Message Type (10.2.17) UE information elements -RRC transaction identifier -Integrity check info 0 Not Present Measurement Information elements -Measurement Identity -Measurement Command -Measurement Reporting Mode - Measurement Report Transfer Mode - Periodical Reporting / Event Trigger Reporting Mode -Additional measurement list -CHOICE Measurement Type -Inter-frequency measurement object list -CHOICE Inter-frequency cell removal -New inter-frequency cells -Cell for measurement -Inter-frequency measurement quantity -CHOICE reporting criteria -Filter coefficient -CHOICE mode -Measurement quantity -Inter-frequency reporting quantity -UTRA Carrier RSSI -Frequency quality estimate -Non frequency related cell reporting quantities -SFN-SFN observed time difference reporting indicator -Cell synchronisation information reporting indicator -Maximum number of reported cells -Measurement validity -Inter-frequency set update -CHOICE report criteria -Amount of reporting -Reporting interval 2 Setup Acknowledged mode RLC Periodical reporting Not Present Inter-RAT measurement Not Present Cell 2 information is included Not Present Inter-frequency reporting criteria 0 GSM RX_LEV FALSE FALSE No report Report all active set cells + cells within monitored set on used frequency Virtual/active set cells + 2 Not Present Not Present Periodical reporting criteria Infinity 500 ms Physical channel information elements -DPCH compressed mode status info Not Present
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.6 SIR
Void
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.7 Transport Channel BLER
Void
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.8 SFN-SFN observed time difference
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.8.1 SFN-SFN observed time difference type 1
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.8.1.1 Measurement accuracy for 3,84 Mcps TDD Option
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.8.1.1.1 Definition and applicability
This measurement is specified in clause 5.1.10 of TS 25.225 [22]. The reference point for the SFN-SFN observed time difference type 1 shall be the antenna connector of the UE. The requirements and this test apply to all types of UTRA TDD UE.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.8.1.1.2 Minimum requirements
The accuracy requirement in table 8.7.8.1.1.1 is valid under the following conditions: P-CCPCH_RSCP1,2  -102 dBm.. where the received P-CCPCH Ec/Io is defined as, and the received SCH Ec/Io is defined as, and SCH_Ec/Ior is equally divided between primary synchronisation code and the sum of all secondary synchronisation codes, where the secondary synchronisation codes are also equally divided. Table 8.7.8.1.1.1: SFN-SFN observed time difference type 1 accuracy Parameter Unit Accuracy [chip] Conditions Io [dBm/3,84 MHz] SFN-SFN observed time difference type 1 chip +/-0,5 -94...-50 The normative reference for this requirement is TS 25.123 [2] clause 9.1.1.8 and A.9.1.8.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.8.1.1.3 Test purpose
The purpose of this test is to verify that the measurement accuracy of SFN-SFN observed time difference type 1 is within the limit specified in clause 8.7.8.1.1.2.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.8.1.1.4 Method of test
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.8.1.1.4.1 Initial conditions
Test environment: normal; see clauses G.2.1 and G.2.2. Frequencies to be tested: mid range; see clause G.2.4. In this case all cells are on the same frequency. Cell 1 and cell 2 shall be synchronised, i.e. share the same frame and timeslot timing. The DL DPCH shall be transmitted in timeslot 4 and the UL DPCH shall be transmitted in timeslot 12. The second Beacon timeslot shall be provided in timeslot 8 for cell 1 and in timeslot 10 for cell 2. During the test, the timing difference between cell 1 and cell 2 can be set to any value from 0…9830400 chip. The SFN-SFN observed time difference type 1 accuracy requirements in the intra-frequency case are tested by using test parameters in Table 8.7.8.1.1.2. Table 8.7.8.1.1.2: SFN-SFN observed time difference type 1 intra frequency test parameters Parameter Unit Test 1 Test 2 Test 3 Cell 1 Cell 2 Cell 1 Cell 2 Cell 1 Cell 2 DL timeslot number 0 2 0 2 0 2 UTRA RF Channel number Channel 1 Channel 1 Channel 1 PCCPCH_Ec/Ior dB -3 -3 -3 SCH_Ec/Ior dB -9 -9 -9 SCH_toffset 0 5 0 5 0 5 OCNS_Ec/Ior dB -3,12 -3,12 -3,12 Ioc dBm / 3,84 MHz -75.2 -75.2 -57.8 -54.7 -98.7 -98.7 Îor/Ioc dB 5 5 7 3 3 3 Io, Note 1 dBm / 3,84 MHz -69 -50 -94 Propagation condition AWGN AWGN AWGN NOTE 1: Io levels have been calculated from other parameters for information purposes. They are not settable parameters themselves. 1) A call is set up according to the test procedure specified in TS 34.108 [3] subclause 7.3.2.3. The RF parameters for Test 1 are set up according to table 8.7.8.1.1.2.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.8.1.1.4.2 Procedure
1) SS shall transmit the MEASUREMENT CONTROL message. 2) UE shall transmit periodically MEASUREMENT REPORT messages. 3) SS shall check "SFN-SFN observed time difference type 1" value in MEASUREMENT REPORT message. The reported value shall be compared to the actually set SFN-SFN observed time difference type 1 value for each MEASUREMENT REPORT message. 4) SS shall count the number of MEASUREMENT REPORT messages transmitted by UE. After 1000 MEASUREMENT REPORT messages have been received from UE, the RF parameters are set up according to table 8.7.8.1.1.2 for Test 2. While RF parameters are being set up, MEASUREMENT REPORT messages from UE are ignored. SS shall wait for additional 1s and ignore the MEASUREMENT REPORT messages during this period. Then, steps 2) and 3) above are repeated. After further 1000 MEASUREMENT REPORT messages have been received from UE, the RF parameters are set up according to table 8.7.8.1.1.2 for Test 3. While RF parameters are being set up, MEASUREMENT REPORT messages from UE are ignored. SS shall wait for additional 1s and ignore the MEASUREMENT REPORT messages during this period. Then, steps 2) and 3) above are repeated. 5) After further 1000 MEASUREMENT REPORT messages have been received from UE, the SS shall transmit RRC CONNECTION RELEASE message. 6) UE shall transmit RRC CONNECTION RELEASE COMPLETE message. Specific Message Contents All messages indicated above shall use the same content as described in the default message content in clause 9 of 34.108 [3] and in Annex I, with the following exceptions: MEASUREMENT CONTROL message (Step 1): Information Element/Group name Value/Remark Message Type (10.2.17) UE information elements -RRC transaction identifier 0 -Integrity check info Not Present Measurement Information elements -Measurement Identity 1 -Measurement Command (10.3.7.46) Modify -Measurement Reporting Mode (10.3.7.49) -Measurement Report Transfer Mode AM RLC -Periodical Reporting / Event Trigger Reporting Mode Periodical reporting -Additional measurements list (10.3.7.1) Not Present -CHOICE Measurement type Intra-frequency measurement -Intra-frequency measurement (10.3.7.36) -Intra-frequency measurement objects list (10.3.7.33) Not Present -Intra-frequency measurement quantity (10.3.7.38) -Filter coefficient (10.3.7.9) 0 -CHOICE mode TDD -Measurement quantity list 1 -Measurement quantity Primary CCPCH RSCP -Intra-frequency reporting quantity (10.3.7.41) -Reporting quantities for active set cells (10.3.7.5) -SFN-SFN observed time difference reporting indicator Type 1 -Cell synchronisation information reporting indicator FALSE -Cell Identity reporting indicator FALSE -CHOICE mode TDD -Timeslot ISCP reporting indicator FALSE -Primary CCPCH RSCP reporting indicator TRUE -Pathloss reporting indicator TRUE -Reporting quantities for monitored set cells (10.3.7.5) -SFN-SFN observed time difference reporting indicator Type 1 -Cell synchronisation information reporting indicator FALSE -Cell Identity reporting indicator FALSE -CHOICE mode TDD -Timeslot ISCP reporting indicator FALSE -Proposed TGSN reporting required FALSE -Primary CCPCH RSCP reporting indicator TRUE -Pathloss reporting indicator TRUE -Reporting quantities for detected set cells (10.3.7.5) Not Present -Reporting cell status (10.3.7.61) -CHOICE reported cell Report all active set cells + cells within monitored set on used frequency -Maximum number of reported cells Virtual/active set cells + 2 -Measurement validity (10.3.7.51) Not Present -CHOICE report criteria (10.3.7. -Periodical reporting criteria (10.3.7.53) -Amount of reporting Infinity -Reporting interval 250 ms Physical channel information elements -DPCH compressed mode status info (10.3.6.34) Not Present
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.8.1.1.5 Test requirements
The SFN-SFN observed time difference type 1 accuracy shall meet the requirements in clause 8.7.8.1.1.2. NOTE: If the above Test Requirement differs from the Minimum Requirement then the Test Tolerance applied for this test is non-zero. The Test Tolerance for this test is defined in clause F.2 and the explanation of how the Minimum Requirement has been relaxed by the Test Tolerance is given in clause F.4. 8.7.8.1.1A Measurement accuracy for 1,28 Mcps TDD Option Void 8.7.8.1.1B Measurement accuracy for 7,68 Mcps TDD Option 8.7.8.1.1B.1 Definition and applicability This measurement is specified in clause 5.1.10 of TS 25.225 [22]. The reference point for the SFN-SFN observed time difference type 1 shall be the antenna connector of the UE. The requirements and this test apply to all types of UTRA TDD UE. 8.7.8.1.1B.2 Minimum requirements The accuracy requirement in table 8.7.8.1.1B.2.1 is valid under the following conditions: P-CCPCH_RSCP1,2  -102 dBm.. where the received P-CCPCH Ec/Io is defined as, and the received SCH Ec/Io is defined as, and SCH_Ec/Ior is equally divided between primary synchronisation code and the sum of all secondary synchronisation codes, where the secondary synchronisation codes are also equally divided. Table 8.7.8.1.1B.2.1: SFN-SFN observed time difference type 1 accuracy Parameter Unit Accuracy [chip] Conditions Io [dBm/7.68 MHz] SFN-SFN observed time difference chip +/-1 for both type 1 and 2 -94...-50 The normative reference for this requirement is TS 25.123 [2] clause 9.1.1.8.1.3 and A.9.3.8. 8.7.8.1.1B.3 Test purpose The purpose of this test is to verify that the measurement accuracy of SFN-SFN observed time difference type 1 is within the limit specified in clause 8.7.8.1.1B.2. 8.7.8.1.1B.4 Method of test 8.7.8.1.1B.4.1 Initial conditions Test environment: normal; see clauses G.2.1 and G.2.2. Frequencies to be tested: mid range; see clause G.2.4. In this case all cells are on the same frequency. Cell 1 and cell 2 shall be synchronised, i.e. share the same frame and timeslot timing. The DL DPCH shall be transmitted in timeslot 4 and the UL DPCH shall be transmitted in timeslot 12. The second Beacon timeslot shall be provided in timeslot 8 for cell 1 and in timeslot 10 for cell 2.During the test, the timing difference between cell 1 and cell 2 can be set to any value from 0…19660800 chip. The SFN-SFN observed time difference type 1 accuracy requirements in the intra-frequency case are tested by using test parameters in Table 8.7.8.1.1B.4.1.1. Table 8.7.8.1.1B.4.1.1: SFN-SFN observed time difference type 1 intra frequency test parameters Parameter Unit Test 1 Test 2 Test 3 Cell 1 Cell 2 Cell 1 Cell 2 Cell 1 Cell 2 DL timeslot number 0 2 0 2 0 2 UTRA RF Channel number Channel 1 Channel 1 Channel 1 PCCPCH_Ec/Ior dB -3 -3 -3 SCH_Ec/Ior dB -9 -9 -9 SCH_toffset 0 5 0 5 0 5 OCNS_Ec/Ior dB -3,12 -3,12 -3,12 Ioc dBm / 7.68 MHz -75.2 -75.2 -57.8 -54.7 -98.7 -98.7 Îor/Ioc dB 5 5 7 3 3 3 Io, Note 1 dBm / 7.68 MHz -69 -50 -94 Propagation condition AWGN AWGN AWGN NOTE 1: Io levels have been calculated from other parameters for information purposes. They are not settable parameters themselves. 1) A call is set up according to the test procedure specified in TS 34.108 [3] subclause 7.3.2.3. The RF parameters for Test 1 are set up according to table 8.7.8.1.1B.4.1.1. 8.7.8.1.1B.4.2 Procedure 1) SS shall transmit the MEASUREMENT CONTROL message. 2) UE shall transmit periodically MEASUREMENT REPORT messages. 3) SS shall check "SFN-SFN observed time difference type 1" value in MEASUREMENT REPORT message. The reported value shall be compared to the actually set SFN-SFN observed time difference type 1 value for each MEASUREMENT REPORT message. 4) SS shall count the number of MEASUREMENT REPORT messages transmitted by UE. After 1000 MEASUREMENT REPORT messages have been received from UE, the RF parameters are set up according to table 8.7.8.1.1B.4.1.1 for Test 2. While RF parameters are being set up, MEASUREMENT REPORT messages from UE are ignored. SS shall wait for additional 1s and ignore the MEASUREMENT REPORT messages during this period. Then, steps 2) and 3) above are repeated. After further 1000 MEASUREMENT REPORT messages have been received from UE, the RF parameters are set up according to table 8.7.8.1.1B.4.1.1 for Test 3. While RF parameters are being set up, MEASUREMENT REPORT messages from UE are ignored. SS shall wait for additional 1s and ignore the MEASUREMENT REPORT messages during this period. Then, steps 2) and 3) above are repeated. 5) After further 1000 MEASUREMENT REPORT messages have been received from UE, the SS shall transmit RRC CONNECTION RELEASE message. 6) UE shall transmit RRC CONNECTION RELEASE COMPLETE message. Specific Message Contents All messages indicated above shall use the same content as described in the default message content in clause 9 of 34.108 [3] and in Annex I, with the following exceptions: MEASUREMENT CONTROL message (Step 1): Information Element/Group name Value/Remark Message Type (10.2.17) UE information elements -RRC transaction identifier 0 -Integrity check info Not Present Measurement Information elements -Measurement Identity 1 -Measurement Command (10.3.7.46) Modify -Measurement Reporting Mode (10.3.7.49) -Measurement Report Transfer Mode AM RLC -Periodical Reporting / Event Trigger Reporting Mode Periodical reporting -Additional measurements list (10.3.7.1) Not Present -CHOICE Measurement type Intra-frequency measurement -Intra-frequency measurement (10.3.7.36) -Intra-frequency measurement objects list (10.3.7.33) Not Present -Intra-frequency measurement quantity (10.3.7.38) -Filter coefficient (10.3.7.9) 0 -CHOICE mode TDD -Measurement quantity list 1 -Measurement quantity Primary CCPCH RSCP -Intra-frequency reporting quantity (10.3.7.41) -Reporting quantities for active set cells (10.3.7.5) -SFN-SFN observed time difference reporting indicator Type 1 -Cell synchronisation information reporting indicator FALSE -Cell Identity reporting indicator FALSE -CHOICE mode TDD -Timeslot ISCP reporting indicator FALSE -Primary CCPCH RSCP reporting indicator TRUE -Pathloss reporting indicator TRUE -Reporting quantities for monitored set cells (10.3.7.5) -SFN-SFN observed time difference reporting indicator Type 1 -Cell synchronisation information reporting indicator FALSE -Cell Identity reporting indicator FALSE -CHOICE mode TDD -Timeslot ISCP reporting indicator FALSE -Proposed TGSN reporting required FALSE -Primary CCPCH RSCP reporting indicator TRUE -Pathloss reporting indicator TRUE -Reporting quantities for detected set cells (10.3.7.5) Not Present -Reporting cell status (10.3.7.61) -CHOICE reported cell Report all active set cells + cells within monitored set on used frequency -Maximum number of reported cells Virtual/active set cells + 2 -Measurement validity (10.3.7.51) Not Present -CHOICE report criteria (10.3.7. -Periodical reporting criteria (10.3.7.53) -Amount of reporting Infinity -Reporting interval 250 ms Physical channel information elements -DPCH compressed mode status info (10.3.6.34) Not Present 8.7.8.1.1B.5 Test requirements The SFN-SFN observed time difference type 1 accuracy shall meet the requirements in clause 8.7.8.1.1B.2. NOTE: If the above Test Requirement differs from the Minimum Requirement then the Test Tolerance applied for this test is non-zero. The Test Tolerance for this test is defined in clause F.2 and the explanation of how the Minimum Requirement has been relaxed by the Test Tolerance is given in clause F.4.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.8.2 SFN-SFN observed time difference type 2
Void
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.9 Observed time difference to GSM cell
Void
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.10 UE GPS Timing of Cell Frames for UP
Void
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.11 SFN-CFN observed time difference
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.11.1 Intra frequency measurement requirement for 3,84 Mcps option
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.11.1.1 Definition and applicability
The intra frequency SFN-CFN observed time difference is defined as the SFN-CFN observed time difference from the active cell to a neighbour cell that is in the same frequency. This measurement is specified in clause 5.1.11 of TS 25.225 [22]. The reference point for the SFN-CFN observed time difference shall be the antenna connector of the UE. The requirements and this test apply to all types of UTRA TDD UE.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.11.1.2 Minimum requirements
The accuracy requirement in table 8.7.11.1.1 is valid under the following conditions: P-CCPCH_RSCP1,2  -102 dBm.. where the received P-CCPCH Ec/Io is defined as, and the received SCH Ec/Io is defined as, and SCH_Ec/Ior is equally divided between primary synchronisation code and the sum of all secondary synchronisation codes, where the secondary synchronisation codes are also equally divided. Table 8.7.11.1.1: SFN-CFN observed time difference accuracy for an intra frequency UTRA TDD neighbour cell Parameter Unit Accuracy [chip] Conditions Io [dBm/3,84 MHz] SFN-CFN observed time difference chip +/-0,5 -94...-50 The normative reference for this requirement is TS 25.123 [2] clause 9.1.1.11 and A.9.1.10.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.11.1.3 Test Purpose
The purpose of this test is to verify that the measurement accuracy of SFN-CFN observed time difference is within the limit specified in clause 8.7.11.1.2.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.11.1.4 Method of test
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.11.1.4.1 Initial conditions
Test environment: normal; see clauses G.2.1 and G.2.2. Frequencies to be tested: mid range; see clause G.2.4. In this case all cells are on the same frequency. Cell 1 and cell 2 shall be synchronised, i.e. share the same frame and timeslot timing. The DL DPCH shall be transmitted in timeslot 4 and the UL DPCH shall be transmitted in timeslot 12. The second Beacon timeslot shall be provided in timeslot 8 for cell 1 and in timeslot 10 for cell 2. During the test, the timing difference between cell 1 and cell 2 can be set to any value from 0…255 frames. The SFN-CFN observed time difference accuracy requirements in the intra-frequency case are tested by using test parameters in Table 8.7.11.1.2. Table 8.7.11.1.2: SFN-CFN observed time difference intra frequency test parameters Parameter Unit Test 1 Test 2 Test 3 Cell 1 Cell 2 Cell 1 Cell 2 Cell 1 Cell 2 DL timeslot number 0 2 0 2 0 2 UTRA RF Channel number Channel 1 Channel 1 Channel 1 PCCPCH_Ec/Ior dB -3 -3 -3 SCH_Ec/Ior dB -9 -9 -9 SCH_toffset 0 5 0 5 0 5 OCNS_Ec/Ior dB -3,12 -3,12 -3,12 Ioc dBm / 3,84 MHz -75.2 -75.2 -57.8 -54.7 -98.7 -98.7 Îor/Ioc dB 5 5 7 3 3 3 Io, Note 1 dBm / 3,84 MHz -69 -50 -94 Propagation condition AWGN AWGN AWGN NOTE 1: Io levels have been calculated from other parameters for information purposes. They are not settable parameters themselves. 1) A call is set up according to the test procedure specified in TS 34.108 [3] subclause 7.3.2.3. The RF parameters for Test 1 are set up according to table 8.7.11.1.2.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.11.1.4.2 Procedure
1) SS shall transmit the MEASUREMENT CONTROL message. 2) UE shall transmit periodically MEASUREMENT REPORT messages. 3) SS shall check "OFF" and "Tm" values in MEASUREMENT REPORT message and calculate SFN-CFN observed time difference value according to the definition in clause 5.1.11 of TS 25.225 [22]. This value shall be compared to the actually set SFN-CFN observed time difference value for each MEASUREMENT REPORT message. 4) SS shall count the number of MEASUREMENT REPORT messages transmitted by UE. After 1000 MEASUREMENT REPORT messages have been received from UE, the RF parameters are set up according to table 8.7.11.1.2 for Test 2. While RF parameters are being set up, MEASUREMENT REPORT messages from UE are ignored. SS shall wait for additional 1s and ignore the MEASUREMENT REPORT messages during this period. Then, steps 2) and 3) above are repeated. After further 1000 MEASUREMENT REPORT messages have been received from UE, the RF parameters are set up according to table 8.7.11.1.2 for Test 3. While RF parameters are being set up, MEASUREMENT REPORT messages from UE are ignored. SS shall wait for additional 1s and ignore the MEASUREMENT REPORT messages during this period. Then, steps 2) and 3) above are repeated. 5) After further 1000 MEASUREMENT REPORT messages have been received from UE, the SS shall transmit RRC CONNECTION RELEASE message. 6) UE shall transmit RRC CONNECTION RELEASE COMPLETE message. Specific Message Contents All messages indicated above shall use the same content as described in the default message content in clause 9 of 34.108 [3] and in Annex I, with the following exceptions: MEASUREMENT CONTROL message (Step 1): Information Element/Group name Value/Remark Message Type (10.2.17) UE information elements -RRC transaction identifier 0 -Integrity check info Not Present Measurement Information elements -Measurement Identity 1 -Measurement Command (10.3.7.46) Modify -Measurement Reporting Mode (10.3.7.49) -Measurement Report Transfer Mode AM RLC -Periodical Reporting / Event Trigger Reporting Mode Periodical reporting -Additional measurements list (10.3.7.1) Not Present -CHOICE Measurement type Intra-frequency measurement -Intra-frequency measurement (10.3.7.36) -Intra-frequency measurement objects list (10.3.7.33) Not Present -Intra-frequency measurement quantity (10.3.7.38) -Filter coefficient (10.3.7.9) 0 -CHOICE mode TDD -Measurement quantity list 1 -Measurement quantity Primary CCPCH RSCP -Intra-frequency reporting quantity (10.3.7.41) -Reporting quantities for active set cells (10.3.7.5) -SFN-SFN observed time difference reporting indicator No report -Cell synchronisation information reporting indicator TRUE -Cell Identity reporting indicator TRUE -CHOICE mode TDD -Timeslot ISCP reporting indicator FALSE -Primary CCPCH RSCP reporting indicator TRUE -Pathloss reporting indicator TRUE -Reporting quantities for monitored set cells (10.3.7.5) -SFN-SFN observed time difference reporting indicator No report -Cell synchronisation information reporting indicator TRUE -Cell Identity reporting indicator TRUE -CHOICE mode TDD -Timeslot ISCP reporting indicator FALSE -Proposed TGSN reporting required FALSE -Primary CCPCH RSCP reporting indicator TRUE -Pathloss reporting indicator TRUE -Reporting quantities for detected set cells (10.3.7.5) Not Present -Reporting cell status (10.3.7.61) -CHOICE reported cell Report all active set cells + cells within monitored set on used frequency -Maximum number of reported cells Virtual/active set cells + 2 -Measurement validity (10.3.7.51) Not Present -CHOICE report criteria (10.3.7. -Periodical reporting criteria (10.3.7.53) -Amount of reporting Infinity -Reporting interval 250 ms Physical channel information elements -DPCH compressed mode status info (10.3.6.34) Not Present
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.11.1.5 Test requirements
The SFN-CFN observed time difference accuracy shall meet the requirements in clause 8.7.11.1.2. NOTE: If the above Test Requirement differs from the Minimum Requirement then the Test Tolerance applied for this test is non-zero. The Test Tolerance for this test is defined in clause F.2 and the explanation of how the Minimum Requirement has been relaxed by the Test Tolerance is given in clause F.4. 8.7.11.1A Intra frequency measurement requirement for 1,28 Mcps option Void 8.7.11.1B Intra frequency measurement requirement for 7,68 Mcps option 8.7.11.1B.1 Definition and applicability The intra frequency SFN-CFN observed time difference is defined as the SFN-CFN observed time difference from the active cell to a neighbour cell that is in the same frequency. This measurement is specified in clause 5.1.11 of TS 25.225 [22]. The reference point for the SFN-CFN observed time difference shall be the antenna connector of the UE. The requirements and this test apply to all types of UTRA TDD UE. 8.7.11.1B.2 Minimum requirements The accuracy requirement in table 8.7.11.1B.2.1 is valid under the following conditions: P-CCPCH_RSCP1,2  -102 dBm.. where the received P-CCPCH Ec/Io is defined as, and the received SCH Ec/Io is defined as, and SCH_Ec/Ior is equally divided between primary synchronisation code and the sum of all secondary synchronisation codes, where the secondary synchronisation codes are also equally divided. Table 8.7.11.1B.2.1: SFN-CFN observed time difference accuracy for an intra frequency UTRA TDD neighbour cell Parameter Unit Accuracy [chip] Conditions Io [dBm/7.68 MHz] SFN-CFN observed time difference chip +/-1 -94...-50 The normative reference for this requirement is TS 25.123 [2] clause 9.1.1.11.1 and A.9.3.10. 8.7.11.1B.3 Test Purpose The purpose of this test is to verify that the measurement accuracy of SFN-CFN observed time difference is within the limit specified in clause 8.7.11.1B.2. 8.7.11.1B.4 Method of test 8.7.11.1B.4.1 Initial conditions Test environment: normal; see clauses G.2.1 and G.2.2. Frequencies to be tested: mid range; see clause G.2.4. In this case all cells are on the same frequency. Cell 1 and cell 2 shall be synchronised, i.e. share the same frame and timeslot timing. The DL DPCH shall be transmitted in timeslot 4 and the UL DPCH shall be transmitted in timeslot 12. The second Beacon timeslot shall be provided in timeslot 8 for cell 1 and in timeslot 10 for cell 2. During the test, the timing difference between cell 1 and cell 2 can be set to any value from 0…255 frames. The SFN-CFN observed time difference accuracy requirements in the intra-frequency case are tested by using test parameters in Table 8.7.11.1B.4.1.1. Table 8.7.11.1B.4.1.1: SFN-CFN observed time difference intra frequency test parameters Parameter Unit Test 1 Test 2 Test 3 Cell 1 Cell 2 Cell 1 Cell 2 Cell 1 Cell 2 DL timeslot number 0 2 0 2 0 2 UTRA RF Channel number Channel 1 Channel 1 Channel 1 PCCPCH_Ec/Ior dB -3 -3 -3 SCH_Ec/Ior dB -9 -9 -9 SCH_toffset 0 5 0 5 0 5 OCNS_Ec/Ior dB -3,12 -3,12 -3,12 Ioc dBm / 7.68 MHz -75.2 -75.2 -57.8 -54.7 -98.7 -98.7 Îor/Ioc dB 5 5 7 3 3 3 Io, Note 1 dBm / 7.68 MHz -69 -50 -94 Propagation condition AWGN AWGN AWGN NOTE 1: Io levels have been calculated from other parameters for information purposes. They are not settable parameters themselves. 1) A call is set up according to the test procedure specified in TS 34.108 [3] subclause 7.3.2.3. The RF parameters for Test 1 are set up according to table 8.7.11.1B.4.1.1. 8.7.11.1B.4.2 Procedure 1) SS shall transmit the MEASUREMENT CONTROL message. 2) UE shall transmit periodically MEASUREMENT REPORT messages. 3) SS shall check "OFF" and "Tm" values in MEASUREMENT REPORT message and calculate SFN-CFN observed time difference value according to the definition in clause 5.1.11 of TS 25.225 [22]. This value shall be compared to the actually set SFN-CFN observed time difference value for each MEASUREMENT REPORT message. 4) SS shall count the number of MEASUREMENT REPORT messages transmitted by UE. After 1000 MEASUREMENT REPORT messages have been received from UE, the RF parameters are set up according to table 8.7.11.1B.4.1.1 for Test 2. While RF parameters are being set up, MEASUREMENT REPORT messages from UE are ignored. SS shall wait for additional 1s and ignore the MEASUREMENT REPORT messages during this period. Then, steps 2) and 3) above are repeated. After further 1000 MEASUREMENT REPORT messages have been received from UE, the RF parameters are set up according to table 8.7.11.1B.4.1.1 for Test 3. While RF parameters are being set up, MEASUREMENT REPORT messages from UE are ignored. SS shall wait for additional 1s and ignore the MEASUREMENT REPORT messages during this period. Then, steps 2) and 3) above are repeated. 5) After further 1000 MEASUREMENT REPORT messages have been received from UE, the SS shall transmit RRC CONNECTION RELEASE message. 6) UE shall transmit RRC CONNECTION RELEASE COMPLETE message. Specific Message Contents All messages indicated above shall use the same content as described in the default message content in clause 9 of 34.108 [3] and in Annex I, with the following exceptions: MEASUREMENT CONTROL message (Step 1): Information Element/Group name Value/Remark Message Type (10.2.17) UE information elements -RRC transaction identifier 0 -Integrity check info Not Present Measurement Information elements -Measurement Identity 1 -Measurement Command (10.3.7.46) Modify -Measurement Reporting Mode (10.3.7.49) -Measurement Report Transfer Mode AM RLC -Periodical Reporting / Event Trigger Reporting Mode Periodical reporting -Additional measurements list (10.3.7.1) Not Present -CHOICE Measurement type Intra-frequency measurement -Intra-frequency measurement (10.3.7.36) -Intra-frequency measurement objects list (10.3.7.33) Not Present -Intra-frequency measurement quantity (10.3.7.38) -Filter coefficient (10.3.7.9) 0 -CHOICE mode TDD -Measurement quantity list 1 -Measurement quantity Primary CCPCH RSCP -Intra-frequency reporting quantity (10.3.7.41) -Reporting quantities for active set cells (10.3.7.5) -SFN-SFN observed time difference reporting indicator No report -Cell synchronisation information reporting indicator TRUE -Cell Identity reporting indicator TRUE -CHOICE mode TDD -Timeslot ISCP reporting indicator FALSE -Primary CCPCH RSCP reporting indicator TRUE -Pathloss reporting indicator TRUE -Reporting quantities for monitored set cells (10.3.7.5) -SFN-SFN observed time difference reporting indicator No report -Cell synchronisation information reporting indicator TRUE -Cell Identity reporting indicator TRUE -CHOICE mode TDD -Timeslot ISCP reporting indicator FALSE -Proposed TGSN reporting required FALSE -Primary CCPCH RSCP reporting indicator TRUE -Pathloss reporting indicator TRUE -Reporting quantities for detected set cells (10.3.7.5) Not Present -Reporting cell status (10.3.7.61) -CHOICE reported cell Report all active set cells + cells within monitored set on used frequency -Maximum number of reported cells Virtual/active set cells + 2 -Measurement validity (10.3.7.51) Not Present -CHOICE report criteria (10.3.7. -Periodical reporting criteria (10.3.7.53) -Amount of reporting Infinity -Reporting interval 250 ms Physical channel information elements -DPCH compressed mode status info (10.3.6.34) Not Present 8.7.11.1B.5 Test requirements The SFN-CFN observed time difference accuracy shall meet the requirements in clause 8.7.11.1B.2. NOTE: If the above Test Requirement differs from the Minimum Requirement then the Test Tolerance applied for this test is non-zero. The Test Tolerance for this test is defined in clause F.2 and the explanation of how the Minimum Requirement has been relaxed by the Test Tolerance is given in clause F.4.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.11.2 Inter frequency measurement requirement for 3,84 Mcps option
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.11.2.1 Definition and applicability
The inter frequency SFN-CFN observed time difference is defined as the SFN-CFN time difference from the active cell to a UTRA TDD neighbour cell that is in a different frequency. This measurement is specified in clause 5.1.11 of TS 25.225 [22]. The reference point for the SFN-CFN observed time difference shall be the antenna connector of the UE. The requirements and this test apply to all types of UTRA TDD UE.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.11.2.2 Minimum requirements
The accuracy requirement in table 8.7.11.2.1 is valid under the following conditions: P-CCPCH_RSCP1,2  -102 dBm.. where the received P-CCPCH Ec/Io is defined as, and the received SCH Ec/Io is defined as, and SCH_Ec/Ior is equally divided between primary synchronisation code and the sum of all secondary synchronisation codes, where the secondary synchronisation codes are also equally divided. Table 8.7.11.2.1: SFN-CFN observed time difference accuracy for an inter frequency UTRA TDD neighbour cell Parameter Unit Accuracy [chip] Conditions Io [dBm/3,84 MHz] SFN-CFN observed time difference chip +/-0,5 -94...-50 The normative reference for this requirement is TS 25.123 [2] clause 9.1.1.11 and A.9.1.10.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.11.2.3 Test purpose
The purpose of this test is to verify that the measurement accuracy of SFN-CFN observed time difference is within the limit specified in clause 8.7.11.2.2.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.11.2.4 Method of test
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.11.2.4.1 Initial conditions
Test environment: normal; see clauses G.2.1 and G.2.2. Frequencies to be tested: mid range; see clause G.2.4. In this case, UTRA TDD cell 1 and UTRA TDD cell 2 are on different frequencies. Cell 1 and cell 2 shall be synchronised, i.e. share the same frame and timeslot timing. The DL DPCH shall be transmitted in timeslot 4 and the UL DPCH shall be transmitted in timeslot 12. The second Beacon timeslot shall be provided in timeslot 8 for cell 1 and in timeslot 10 for cell 2. During the test, the timing difference between cell 1 and cell 2 can be set to any value from 0…256 frames. The SFN-CFN observed time difference accuracy requirements in the intra-frequency case are tested by using test parameters in Table 8.7.11.2.2. Table 8.7.11.2.2: SFN-CFN observed time difference inter frequency test parameters Parameter Unit Test 1 Test 2 Test 3 Cell 1 Cell 2 Cell 1 Cell 2 Cell 1 Cell 2 DL timeslot number 0 2 0 2 0 2 UTRA RF Channel number Channel 1 Channel 2 Channel 1 Channel 2 Channel 1 Channel 2 PCCPCH_Ec/Ior dB -3 -3 -3 SCH_Ec/Ior dB -9 -9 -9 SCH_toffset 0 5 0 5 0 5 OCNS_Ec/Ior dB -3,12 -3,12 -3,12 Ioc dBm / 3,84 MHz -75.2 -75.2 -57.8 -54.7 -98.7 -98.7 Îor/Ioc dB 5 5 7 3 3 3 Io, Note 1 dBm / 3,84 MHz -69 -50 -94 Propagation condition AWGN AWGN AWGN NOTE 1: Io levels have been calculated from other parameters for information purposes. They are not settable parameters themselves. 1) A call is set up according to the test procedure specified in TS 34.108 [3] subclause 7.3.2.3. The RF parameters for Test 1 are set up according to table 8.7.11.2.2.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.11.2.4.2 Procedure
1) SS shall transmit the MEASUREMENT CONTROL message. 2) UE shall transmit periodically MEASUREMENT REPORT messages. 3) SS shall check "OFF" and "Tm" values in MEASUREMENT REPORT message and calculate SFN-CFN observed time difference value according to the definition in clause 5.1.11 of TS 25.225 [22]. This value shall be compared to the actually set SFN-CFN observed time difference value for each MEASUREMENT REPORT message. 4) SS shall count the number of MEASUREMENT REPORT messages transmitted by UE. After 1000 MEASUREMENT REPORT messages have been received from UE, the RF parameters are set up according to table 8.7.11.2.2 for Test 2. While RF parameters are being set up, MEASUREMENT REPORT messages from UE are ignored. SS shall wait for additional 1s and ignore the MEASUREMENT REPORT messages during this period. Then, steps 2) and 3) above are repeated. After further 1000 MEASUREMENT REPORT messages have been received from UE, the RF parameters are set up according to table 8.7.11.2.2 for Test 3. While RF parameters are being set up, MEASUREMENT REPORT messages from UE are ignored. SS shall wait for additional 1s and ignore the MEASUREMENT REPORT messages during this period. Then, steps 2) and 3) above are repeated. 5) After further 1000 MEASUREMENT REPORT messages have been received from UE, the SS shall transmit RRC CONNECTION RELEASE message. 6) UE shall transmit RRC CONNECTION RELEASE COMPLETE message. Specific Message Contents All messages indicated above shall use the same content as described in the default message content in clause 9 of 34.108 [3] and in Annex I, with the following exceptions: MEASUREMENT CONTROL message for inter frequency measurements (Step 1): Information Element/Group name Value/Remark Message Type (10.2.17) UE information elements -RRC transaction identifier 0 -Integrity check info Not Present Measurement Information elements -Measurement Identity 2 -Measurement Command (10.3.7.46) Setup -Measurement Reporting Mode (10.3.7.49) -Measurement Report Transfer Mode AM RLC -Periodical Reporting / Event Trigger Reporting Mode Periodical reporting -Additional measurements list (10.3.7.1) Not Present -CHOICE Measurement type Inter-frequency measurement -Inter-frequency measurement (10.3.7.16) -Inter-frequency measurement objects list (10.3.7.13) -CHOICE inter-frequency cell removal Not present -New inter-frequency cells Cell 2 information is included -Cell for measurement Not Present -Inter-frequency measurement quantity (10.3.7.18) -CHOICE reporting critera Inter-frequency reporting criteria -Filter coefficient (10.3.7.9) 0 -CHOICE mode TDD -Measurement quantity for frequency quality estimate Primary CCPCH RSCP -Inter-frequency reporting quantity (10.3.7.21) -UTRA carrier RSSI FALSE -Frequency quality estimate TRUE -Non frequency related cell reporting quantities (10.3.7.5) -SFN-SFN observed time difference reporting indicator No report -Cell synchronisation information reporting indicator TRUE -Cell identity reporting indicator TRUE -CHOICE mode TDD -Timeslot ISCP reporting indicator FALSE -Proposed TGSN Reporting required FALSE -Primary CCPCH RSCP reporting indicator TRUE -Pathloss reporting indicator FALSE -Reporting cell status (10.3.7.61) -CHOICE reported cell Report all active set cells + cells within monitored set on used frequency -Maximum number of reported cells Virtual/active set cells + 2 -Measurement validity (10.3.7.51) Not present -Inter-frequency set update Not present -CHOICE report criteria (10.3.7. -Periodical reporting criteria (10.3.7.53) -Amount of reporting Infinity -Reporting interval 500 ms Physical channel information elements -DPCH compressed mode status info (10.3.6.34) Not Present
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.11.2.5 Test requirements
The SFN-CFN observed time difference accuracy shall meet the requirements in clause 8.7.11.2.2. NOTE: If the above Test Requirement differs from the Minimum Requirement then the Test Tolerance applied for this test is non-zero. The Test Tolerance for this test is defined in clause F.2 and the explanation of how the Minimum Requirement has been relaxed by the Test Tolerance is given in clause F.4. 8.7.11.2A Inter frequency measurement requirement for 1,28 Mcps option Void 8.7.11.2B Inter frequency measurement requirement for 7,68 Mcps option 8.7.11.2B.1 Definition and applicability The inter frequency SFN-CFN observed time difference is defined as the SFN-CFN time difference from the active cell to a UTRA TDD neighbour cell that is in a different frequency. This measurement is specified in clause 5.1.11 of TS 25.225 [22]. The reference point for the SFN-CFN observed time difference shall be the antenna connector of the UE. The requirements and this test apply to 7.68Mcps TDD UE. 8.7.11.2B.2 Minimum requirements The accuracy requirement in table 8.7.11.2B.2.1 is valid under the following conditions: P-CCPCH_RSCP1,2  -102 dBm.. where the received P-CCPCH Ec/Io is defined as, and the received SCH Ec/Io is defined as, and SCH_Ec/Ior is equally divided between primary synchronisation code and the sum of all secondary synchronisation codes, where the secondary synchronisation codes are also equally divided. Table 8.7.11.2B.2.1: SFN-CFN observed time difference accuracy for an inter frequency UTRA TDD neighbour cell Parameter Unit Accuracy [chip] Conditions Io [dBm/7.68 MHz] SFN-CFN observed time difference chip +/-1 -94...-50 The normative reference for this requirement is TS 25.123 [2] clause 9.1.1.11.1 and A.9.3.10. 8.7.11.2B.3 Test purpose The purpose of this test is to verify that the measurement accuracy of SFN-CFN observed time difference is within the limit specified in clause 8.7.11.2B.2. 8.7.11.2B.4 Method of test 8.7.11.2B.4.1 Initial conditions Test environment: normal; see clauses G.2.1 and G.2.2. Frequencies to be tested: mid range; see clause G.2.4. In this case, UTRA TDD cell 1 and UTRA TDD cell 2 are on different frequencies. Cell 1 and cell 2 shall be synchronised, i.e. share the same frame and timeslot timing. The DL DPCH shall be transmitted in timeslot 4 and the UL DPCH shall be transmitted in timeslot 12. The second Beacon timeslot shall be provided in timeslot 8 for cell 1 and in timeslot 10 for cell 2. During the test, the timing difference between cell 1 and cell 2 can be set to any value from 0…256 frames. The SFN-CFN observed time difference accuracy requirements in the intra-frequency case are tested by using test parameters in Table 8.7.11.2B.4.1.1. Table 8.7.11.2B.4.1.1: SFN-CFN observed time difference inter frequency test parameters Parameter Unit Test 1 Test 2 Test 3 Cell 1 Cell 2 Cell 1 Cell 2 Cell 1 Cell 2 DL timeslot number 0 2 0 2 0 2 UTRA RF Channel number Channel 1 Channel 2 Channel 1 Channel 2 Channel 1 Channel 2 PCCPCH_Ec/Ior dB -3 -3 -3 SCH_Ec/Ior dB -9 -9 -9 SCH_toffset 0 5 0 5 0 5 OCNS_Ec/Ior dB -3,12 -3,12 -3,12 Ioc dBm / 7.68 MHz -75.2 -75.2 -57.8 -54.7 -98.7 -98.7 Îor/Ioc dB 5 5 7 3 3 3 Io, Note 1 dBm / 7.68 MHz -69 -50 -94 Propagation condition AWGN AWGN AWGN NOTE 1: Io levels have been calculated from other parameters for information purposes. They are not settable parameters themselves. 1) A call is set up according to the test procedure specified in TS 34.108 [3] subclause 7.3.2.3. The RF parameters for Test 1 are set up according to table 8.7.11.2B.4.1.1. 8.7.11.2.4B.2 Procedure 1) SS shall transmit the MEASUREMENT CONTROL message. 2) UE shall transmit periodically MEASUREMENT REPORT messages. 3) SS shall check "OFF" and "Tm" values in MEASUREMENT REPORT message and calculate SFN-CFN observed time difference value according to the definition in clause 5.1.11 of TS 25.225 [22]. This value shall be compared to the actually set SFN-CFN observed time difference value for each MEASUREMENT REPORT message. 4) SS shall count the number of MEASUREMENT REPORT messages transmitted by UE. After 1000 MEASUREMENT REPORT messages have been received from UE, the RF parameters are set up according to table 8.7.11.2B.4.1.1 for Test 2. While RF parameters are being set up, MEASUREMENT REPORT messages from UE are ignored. SS shall wait for additional 1s and ignore the MEASUREMENT REPORT messages during this period. Then, steps 2) and 3) above are repeated. After further 1000 MEASUREMENT REPORT messages have been received from UE, the RF parameters are set up according to table 8.7.11.2B.4.1.1 for Test 3. While RF parameters are being set up, MEASUREMENT REPORT messages from UE are ignored. SS shall wait for additional 1s and ignore the MEASUREMENT REPORT messages during this period. Then, steps 2) and 3) above are repeated. 5) After further 1000 MEASUREMENT REPORT messages have been received from UE, the SS shall transmit RRC CONNECTION RELEASE message. 6) UE shall transmit RRC CONNECTION RELEASE COMPLETE message. Specific Message Contents All messages indicated above shall use the same content as described in the default message content in clause 9 of 34.108 [3] and in Annex I, with the following exceptions: MEASUREMENT CONTROL message for inter frequency measurements (Step 1): Information Element/Group name Value/Remark Message Type (10.2.17) UE information elements -RRC transaction identifier 0 -Integrity check info Not Present Measurement Information elements -Measurement Identity 2 -Measurement Command (10.3.7.46) Setup -Measurement Reporting Mode (10.3.7.49) -Measurement Report Transfer Mode AM RLC -Periodical Reporting / Event Trigger Reporting Mode Periodical reporting -Additional measurements list (10.3.7.1) Not Present -CHOICE Measurement type Inter-frequency measurement -Inter-frequency measurement (10.3.7.16) -Inter-frequency measurement objects list (10.3.7.13) -CHOICE inter-frequency cell removal Not present -New inter-frequency cells Cell 2 information is included -Cell for measurement Not Present -Inter-frequency measurement quantity (10.3.7.18) -CHOICE reporting critera Inter-frequency reporting criteria -Filter coefficient (10.3.7.9) 0 -CHOICE mode TDD -Measurement quantity for frequency quality estimate Primary CCPCH RSCP -Inter-frequency reporting quantity (10.3.7.21) -UTRA carrier RSSI FALSE -Frequency quality estimate TRUE -Non frequency related cell reporting quantities (10.3.7.5) -SFN-SFN observed time difference reporting indicator No report -Cell synchronisation information reporting indicator TRUE -Cell identity reporting indicator TRUE -CHOICE mode TDD -Timeslot ISCP reporting indicator FALSE -Proposed TGSN Reporting required FALSE -Primary CCPCH RSCP reporting indicator TRUE -Pathloss reporting indicator FALSE -Reporting cell status (10.3.7.61) -CHOICE reported cell Report all active set cells + cells within monitored set on used frequency -Maximum number of reported cells Virtual/active set cells + 2 -Measurement validity (10.3.7.51) Not present -Inter-frequency set update Not present -CHOICE report criteria (10.3.7. -Periodical reporting criteria (10.3.7.53) -Amount of reporting Infinity -Reporting interval 500 ms Physical channel information elements -DPCH compressed mode status info (10.3.6.34) Not Present 8.7.11.2B.5 Test requirements The SFN-CFN observed time difference accuracy shall meet the requirements in clause 8.7.11.2B.2. NOTE: If the above Test Requirement differs from the Minimum Requirement then the Test Tolerance applied for this test is non-zero. The Test Tolerance for this test is defined in clause F.2 and the explanation of how the Minimum Requirement has been relaxed by the Test Tolerance is given in clause F.4.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.12 UE transmitted power
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.12.1 UE transmitted power for 3.84 Mcps TDD Option
Void 8.7.12.1A UE transmitted power for 1.28 Mcps TDD Option 8.7.12.1A.1 Definition and applicability The UE transmitted power absolute accuracy is defined as difference between the UE reported value and the UE transmitted power measured by test system. The reference point for the UE transmitted power shall be the antenna connector of the UE. The requirements and this test apply to all types of 1.28 Mcps TDD UE. 8.7.12.1A.2 Minimum requirements The measurement period in CELL_DCH state and CELL_FACH state is 1 slot. Table 8.7.12.1A.2.1 UE transmitted power absolute accuracy Parameter Unit Accuracy [dB] PUEMAX 24dBm PUEMAX 21dBm UE transmitted power  PUEMAX dBm +1/-3 2 PUEMAX > UE transmitted power  PUEMAX-1 dBm +1,5/-3,5 2,5 PUEMAX-1 > UE transmitted power  PUEMAX-2 dBm +2/-4 3 PUEMAX-2 > UE transmitted power  PUEMAX-3 dBm +2,5/-4,5 3,5 PUEMAX-3 > UE transmitted power  PUEMAX-10 dBm +3/-5 4 NOTE 1: User equipment maximum output power, PUEMAX, is the maximum output power level without tolerance defined for the power class of the UE in 3GPP TS 25.102 "UTRA (UE) TDD; Radio Transmission and Reception". NOTE 2: UE transmitted power is the reported value. The normative reference for this requirement is TS 25.123 clause 9.1.2.1. 8.7.12.1A.3 Test purpose The purpose of this test is to verify that for any reported value of UE Transmitted Power in the range PUEMAX to PUEMAX-10 that the actual UE mean power lies within the range specified in clause 8.7.12.1A.2. 8.7.12.1A.4 Method of test 8.7.12.1A.4.1 Initial conditions Test environment: normal, TL/VL, TL/VH, TH/VL, TH/VH; see clauses G.2.1 and G.2.2. Frequencies to be tested: mid range; see clause G.2.4. 1) Connect SS to the UE antenna connector as shown in figure A.1. The test parameters are given in Table 8.7.12.1A.4.1 and 8.7.12.1A.4.2 below. In the measurement control information it shall be indicated to the UE that periodic reporting of the UE transmitted power measurement shall be used. Table 8.7.12.1A.4.1: General test parameters for UE transmitted power Parameter Unit Value Comment DCH parameters DL Reference Measurement Channel 12.2 kbps As specified in clause C.3.1.2 DL-Power Control Off Table 8.7.12.1A.4.2: Cell Specific parameters for UE transmitted power Parameter Unit Cell 1 Timeslot Number 0 DwPTS UTRA RF Channel Number (NOTE 2) Channel 1 PCCPCH_Ec/Ior dB -3 D wPCH _Ec/Ior dB 0 OCNS_Ec/Ior dB - 3 dB 3 dBm/1.28 MHz -70 PCCPCH_RSCP (NOTE 1) dBm -70 Propagation Condition AWGN NOTE 1: PCCPCH RSCP level has been calculated from other parameters for information purposes. They are not settable parameters themselves. NOTE2: In the case of multi-frequency network, the UTRA RF Channel Number can be set for the primary frequency in this test. 8.7.12.1A.4.2 Procedure 1) A call is set up according to the test procedure specified in TS 34.108 [3] subclause 7.3.2. The RF parameters are set up according to table 8.7.12.1A.4.1 and 8.7.12.1A.4.2. Set the UE power and Maximum allowed UL TX power to the maximum power for the UE power class. 2) SS shall send continuously during the entire test Up power control commands to the UE. 3) SS shall transmit the MEASUREMENT CONTROL message as defined in the specific message contents below. 4) Decode the UE Transmitted power reported by the UE in the next available MEASUREMENT REPORT message. 5) Measure the mean power of the UE over a period of one timeslot. 6) Steps 4 and 5 shall be repeated until statistical significance according to Annex F.6.2.8 is achieved. 7) Decrease the Maximum allowed UL TX power by 1 dB. The SS shall transmit the PHYSICAL CHANNEL RECONFIGURATION message, as defined in the specific message contents below. 8) SS shall wait for the PHYSICAL CHANNEL RECONFIGURATION COMPLETE message from the UE. 9) Repeat from step 4) until the Maximum allowed UL TX Power reaches PUEMAX-10. Specific Message Contents All messages indicated above shall use the same content as described in default message content in clause 9 of 34.108 [3], with the following exceptions: MEASUREMENT CONTROL message: Information Element Value/Remark Message Type UE information elements -RRC transaction identifier -Integrity check info -message authentication code -RRC message sequence number 0 SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. SS provides the value of this IE, from its internal counter. Measurement Information elements -Measurement Identity -Measurement Command -CHOICE Measurement type -UE Internal measurement quantity -Measurement quantity -Filter coefficient -UE Internal reporting quantity -UE Transmitted power -CHOICE mode -CHOICE TDD option -1.28Mcps TDD -Tadv info -CHOICE report criteria -Amount of reporting -Reporting interval -Measurement Reporting Mode -Measurement Report Transfer Mode -Periodical Reporting / Event Trigger Reporting Mode -AdditionalMeasurementList 5 SETUP UE Internal measurement UE Transmitted power 0 TRUE TDD False Periodical reporting criteria Infinity 250 AM RLC Periodical reporting Not Present MEASUREMENT REPORT message: Information Element Value/remark Message Type Integrity check info The presence of this IE is dependent on PIXIT statements in TS 34.123-2. If integrity protection is indicated to be active, this IE shall be present with the values of the sub IEs as stated below. Else, this IE and the sub-IEs shall be absent. - Message authentication code This IE is checked to see if it is present. The value is compared against the XMAC-I value computed by SS. - RRC Message sequence number This IE is checked to see if it is present. The value is used by SS to compute the XMAC-I value. Measurement identity 5 Measured Results - CHOICE Measurement UE Internal measured results - Choice mode TDD - UE Transmitted power list Checked that this IE is present -UE Transmitted power Checked that this IE is present - CHOICE TDD option -1.28Mcps TDD -Tadv Checked that this IE is absent Measured results on RACH Checked that this IE is absent Additional measured results Checked that this IE is absent Event results Checked that this IE is absent PHYSICAL CHANNEL RECONFIGURATION message: Information Element Value/Remark Version Message Type UE Information Elements -RRC transaction identifier -Integrity check info -message authentication code -RRC message sequence number -Integrity protection mode info -Ciphering mode info -Activation time -New U-RNTI -New C-RNTI -RRC State Indicator -UTRAN DRX cycle length coefficient 0 SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. SS provides the value of this IE, from its internal counter. Not Present Not Present Not Present Not Present Not Present CELL_DCH Not Present CN Information Elements -CN Information info Not Present UTRAN mobility information elements -URA identity Not Present RB information elements -Downlink counter synchronisation info Not Present PhyCH information elements -Frequency info Not Present Uplink radio resources -Maximum allowed UL TX power At the first time this value is set to PUEMAX-1. After the second time this value is decreased with 1 dB from previous value. 8.7.12.1A.5 Test requirements Compare each of the UE transmitted power reports against the following mean power measurement. At least 90% of the mean power measurements for any one value of reported UE transmitted power shall be within the range specified in table 8.7.12.1A.5. Table 8.7.12.1A.5 UE transmitted power test requirements UE reported value SS measured mean power (X) range [dBm] PUEMAX 24dBm PUEMAX 21dBm UE_TX_POWER_104 33-3.7  X < 34+1.7 33-2.7  X < 34+2.7 UE_TX_POWER_103 32-3.7  X < 33+1.7 32-2.7  X < 33+2.7          UE_TX_POWER_097 26-3.7  X < 27+1.7  UE_TX_POWER_096 25-3.7  X < 26+1.7  UE_TX_POWER_095 24-3.7  X < 25+1.7  UE_TX_POWER_094 23-4.2  X < 24+2.2 23-2.7  X < 24+2.7 UE_TX_POWER_093 22-4.7  X < 23+2.7 22-2.7  X < 23+2.7 UE_TX_POWER_092 21-5.2  X < 22+3.2 21-2.7  X < 22+2.7 UE_TX_POWER_091 20-5.7  X < 21+3.7 20-3.2  X < 21+3.2 UE_TX_POWER_090 19-5.7  X < 20+3.7 19-3.7  X < 20+3.7 UE_TX_POWER_089 18-5.7  X < 19+3.7 18-4.2  X < 19+4.2 UE_TX_POWER_088  17-4.7  X < 18+4.7 UE_TX_POWER_087  16-4.7  X < 17+4.7 UE_TX_POWER_086  15-4.7  X < 15+4.7          UE_TX_POWER_022 -49-5.7  X < -48+3.7 -49-4.7  X < -48+4.7 UE_TX_POWER_021 -50-5.7  X < -49+3.7 -50-4.7  X < -49+4.7 NOTE 1: Although test requirements are given for all UE reported values, a good UE will likely report values between PUEMAX and PUEMAX - 10 dB. However, even a good UE may report also wider range of values due to errors in TPC command reception and allowed range specified for UE transmit power setting accuracy when Maximum Allowed UL TX Power has been signaled. On the other hand, a faulty UE may report any power value but then it does not fulfill the Table 8.7.12.1A.5 requirements for mean power or then it will not pass some other tests e.g. TC 5.2 of this specification. NOTE 2: If the above Test Requirement differs from the Minimum Requirement then the Test Tolerance applied for this test is non-zero. The Test Tolerance for this test is defined in clause F.2 and the explanation of how the Minimum Requirement has been relaxed by the Test Tolerance is given in clause F.4.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.13 UE Transmission Power Headroom
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.13.1 UPH for 3.84Mcps TDD Option
Void 8.7.13.1A UPH for 1.28Mcps TDD Option 8.7.13.1A.1 Definition and applicability The accuracy requirements for the UE transmission power headroom depends on the total power transmitted by the UE as defined in the functionality in section 9.2.6.3 of TS 25.321[14], section 9.1.2.3.2 of TS 25.123 [2] and section 5.1.16 of TS 25.225 [22]. The requirements and this test apply to Release 7 and later releases for all types of UTRA for the 1.28Mcps TDD UE that supports E-DCH and HSDPA. 8.7.13.1A.2 Minimum Requirements The UE transmission power headroom (UPH) is defined in section 5.1.16 of TS 25.225 [22] as the ratio of the maximum UE transmission power and the product of P e-base power and serving cell path loss, and shall be calculated as following: Where: P max, tx = min {Maximum allowed UL TX Power, P max} is the UE maximum transmission power; Maximum allowed UL TX Power is set by UTRAN and defined in [9]; P max is the UE nominal maximum output power according to the UE power class and specified in [1] table 6.1; P e-base is a closed-loop quantity defined in [9] and L Path_loss is the serving cell path loss. The reference point for the UE transmission power headroom shall be the antenna connector of the UE. The accuracy requirements for UE transmission power headroom depends on the total power transmitted by the UE. Table 8.7.13.1A defines the accuracy of the measured quantity as defined in section 9.1.2.3.2 of TS 25.123 [2]. Table 8.7.13.1A.1: UPH reporting accuracy Total UE output power value (dBm) UPH reporting Accuracy [dB]* PUEMAX 24dBm PUEMAX 21dBm Total output power  PUEMAX +1/-3 2 PUEMAX-1 Total output power <PUEMAX +1,5/-3,5 2,5 PUEMAX-2 Total output power <PUEMAX-1 +2/-4 3 PUEMAX-3 Total output power <PUEMAX-2 +2,5/-4,5 3,5 PUEMAX-10 Total output power <PUEMAX-3 +3/-5 4 *Note: UPH reporting accuracy is the difference between the UPH reported by the UE and the actual uplink power headroom **Note: PUEMAX, is the maximum output power level without tolerance defined for the power class of the UE in 3GPP TS 25.102 8.7.13.1A.3 Test purpose The purpose of this test case is to verify that the UE transmission power headroom measurement report accuracy is within the specified limits defined in section 9.1.2.3.2 of 25.123 [2] shown in table 8.7.13.1A.1. 8.7.13.1A.4 Method of test 8.7.13.1A.4.1 Initial conditions Test environment: normal, TL/VL, TL/VH, TH/VL, TH/VH; see clauses G.2.1 and G.2.2. Frequencies to be tested: mid range; see clause G.2.4. 1) Connect the SS (node B emulator) to the UE antenna connector as shown in figure A.1. 2) HSDPA and E-DCH configurations are set as in table 8.7.13.1A.2. Table 8.7.13.1A.2: General test parameters for UE transmission power headroom Parameter Unit Value Comment DL DCH configuration DL Reference Measurement Channel 12.2 kbps As specified in Annex C.3.1.2 of the present document DL configuration DL Fixed Reference Channel (FRC 1) As specified in Annex C.4.2.1 of the present document E-DCH configuration 5 ms TTI E-DCH Transport Block Size Table 0 according to TS 25.321 [13] annex BC.1 DL Power Control Off Active cell Cell 1 Reference E-TFCI index 0 as per Table 0 according to TS 25.321 [13] annex BC.1. 3) The power levels and cell specific parameters are set as in table 8.7.13.1A.3. Table 8.7.13.1A.3: Cell Specific parameters for UE transmission power headroom Parameter Unit Cell 1 Timeslot Number 0 DwPTS UTRA RF Channel Number (NOTE 2) Channel 1 PCCPCH_Ec/Ior dB - 3 D wPCH _Ec/Ior dB 0 OCNS_Ec/Ior dB - 3 dB 3 dBm/ 1.28 MHz -70 PCCPCH RSCP, Note 1 dB m -70 Propagation Condition AWGN NOTE 1: PCCPCH RSCP level has been calculated from other parameters for information purposes. They are not settable parameters themselves. NOTE2: In the case of multi-frequency network, the UTRA RF Channel Number can be set for the primary frequency in this test. 4) The UE is switched on. 5) An E-DCH call is set up according to TS 34.108 [3] 7.3.9 with the following exceptions in the RADIO BEARER SETUP message. These e exceptions are derived from Table 8.7.13.2, and in addition allow the beta values to be set and each UL physical channel to be at constant power during the measurement. Table 8.7.13.1A.4: Contents of RADIO BEARER SETUP message: AM or UM (E-DCH and HSDPA) Information Element/Group name Value/Remark E-PUCH Info(TDD only) >E-TFCS information >>Reference Beta Information QPSK list >>>Reference Code Rate 0.2 >>>Reference Beta -14 >>Reference Beta Information QPSK list >>>Reference Code Rate 0.3 >>>Reference Beta -13 >>Reference Beta Information QPSK list >>>Reference Code Rate 0.4 >>>Reference Beta -12 >>Reference Beta Information QPSK list >>>Reference Code Rate 0.5 >>>Reference Beta -10 >>Reference Beta Information QPSK list >>>Reference Code Rate 0.6 >>>Reference Beta -9 >>Reference Beta Information QPSK list >>>Reference Code Rate 0.7 >>>Reference Beta -8 >>Reference Beta Information QPSK list >>>Reference Code Rate 0.8 >>>Reference Beta -7 >>Reference Beta Information QPSK list >>>Reference Code Rate 0.9 >>>Reference Beta -6 >>Reference Beta Information 16QAM list >>>Reference Code Rate 0.2 >>>Reference Beta -9 >>Reference Beta Information 16QAM list >>>Reference Code Rate 0.3 >>>Reference Beta -8 >>Reference Beta Information 16QAM list >>>Reference Code Rate 0.4 >>>Reference Beta -6 >>Reference Beta Information 16QAM list >>>Reference Code Rate 0.5 >>>Reference Beta -5 >>Reference Beta Information 16QAM list >>>Reference Code Rate 0.6 >>>Reference Beta -4 >>Reference Beta Information 16QAM list >>>Reference Code Rate 0.7 >>>Reference Beta -2 >>Reference Beta Information 16QAM list >>>Reference Code Rate 0.8 >>>Reference Beta -1 >>Reference Beta Information 16QAM list >>>Reference Code Rate 0.9 >>>Reference Beta 0 >CHOICE TDD mode >>1.28 Mcps TDD >>>PRXdes­_base -85 >>>Beacon PL Est. >>>TPC step size 1 >>>E-PUCH TS configuration list >>>>TS number 1 >>>E-PUCH TS configuration list >>>>TS number 2 >>>Minimum allowed code rate 3(0.1) >>>Maximum allowed code rate 50(0.8) 8.7.13.1A.4.2 Test procedure 1) The Scheduling Information configuration for the E-DCH indicates to the UE that it shall periodically report Scheduling Information, which contains UPH measurement every E-DCH TTI. During the test the system simulator shall not send any scheduling grant to the UE, and therefore the UE will not send any payload data on the E-DCH. 2) The SS shall set the CPRI value in E-AGCH to be 3 dB for a power class 3 UE, or 0 dB for a power class 4 UE by using uplink power control. CRRI and TRRI value in E-AGCH respectively is “00100”and “11000”. 3) The SS measures both the power transmitted by the UE on E-PUCH and the total output power of the UE in time slot which assigned E-PUCH transmitted by SS. The SS shall analyse the E-TFCI transmitted on the E-UCCH for each E-DCH TTI and estimates the e. The SS averages both the E-PUCH output power,e and total output power of the UE over 100 times. Then, the SS calculates the difference between average E-PUCH power measured and e. 4) The SS estimates the UE transmission power headroom as the difference between the maximum allowed uplink transmits power (P max) and the difference calculated in step 3. 5) The SS notes the UE transmission power headroom value reported in the Scheduling Information. 6) The SS calculates the difference between the UE transmission power headroom value estimated in step 4 and the reported UE transmission power headroom noted in step 5. The SS notes this as the UE transmission power headroom accuracy, and compares it to the applicable limit according to the total output power measured in step 3. 7) If the UE transmission power headroom accuracy exceeds the value in Table 8.7.13.1A.5 count a bad result, otherwise a good result with respect to the actually set TX power. 8) Repeat steps 3 to 7 in order to collect more good or bad results for the currently set power level. Continue the repetition, until statistical significance according to Annex F.6.2.8 is achieved. 9) The SS sends 5 up TPC commands at the nesting E-AGCH to bring the TX power of the UE up by a nominal 1 dB step, and then alternate UP/DOWN to maintain constant TX power. 10) Repeat steps 3 through 9 and note the UE transmission power headroom accuracy for each UE total power value until the UE stops reporting UPH or does not give lower UPH values for 8 consecutive repetitions of steps 3 through 9. 8.7.13.1A.5 Test requirements The UE transmission power headroom measurement report accuracy recorded in steps 6, 9 and 10 above shall meet the requirements in table 8.7.13.1A.5. The rate of correct measurements observed during repeated tests shall be at least 90%. To pass the test, the UE transmission power headroom accuracy for each power level in the reporting range must pass. Once a power level is passed, no more results need be collected on this power level. Table 8.7.13.1A.5: Test requirement for UPH reporting accuracy Total UE output power value (dBm) UPH reporting Accuracy [dB]* PUEMAX 24dBm PUEMAX 21dBm Total output power  PUEMAX +1.7/-3.7 2.7 PUEMAX-1 Total output power <PUEMAX +2.2/-4.2 3.2 PUEMAX-2 Total output power <PUEMAX-1 +2.7/-4.7 3.7 PUEMAX-3 Total output power <PUEMAX-2 +3.2/-5.2 4.2 PUEMAX-10 Total output power <PUEMAX-3 +3.7/-5.7 4.7 *Note: UPH reporting accuracy is the difference between the UPH reported by the UE and the actual uplink power headroom **Note: PUEMAX, is the maximum output power level without tolerance defined for the power class of the UE in 3GPP TS 25.102 NOTE1: If the above Test Requirement differs from the Minimum Requirement then the Test Tolerance applied for this test is non-zero. The Test Tolerance for this test is defined in clause F.2 and the explanation of how the Minimum Requirement has been relaxed by the Test Tolerance is given in clause F.4. 8.7.13.1B UPH for 7.68Mcps TDD Option Void
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.14 E-UTRAN FDD RSRP
Editor’s note: This Test case is incomplete for frequencies above 3GHz • The Test system uncertainties applicable above 3GHz are undefined • The Test Tolerances and Test Requirements applicable above 3GHz are undefined
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.14.1 Definition and applicability
The absolute accuracy of RSRP is defined as the RSRP measured from a cell that has different carrier frequency from the serving cell. The E-UTRAN FDD RSRP absolute accuracy measurement is used for handover between UTRAN TDD and E-UTRAN FDD for Rel.9 and later. The requirements and this test apply to the combined UTRAN TDD and E-UTRAN FDD UE.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.14.2 Minimum Requirements
In Cell DCH state, whether or not UE requires idle intervals to perform E-UTRAN measurements, the requirements for accuracy of E-UTRA RSRP measurements in CELL_DCH state shall be the same as the inter-frequency RSRP Accuracy Requirements in 3GPP TS 36.133, as follows: Cell specific reference signals are transmitted either from one, two or four antenna ports. Conditions defined in 36.101 Section 7.3 for reference sensitivity are fulfilled. RSRP|dBm according to 36.133 Annex B.3.3 for a corresponding Band Table 8.7.14.2-1: RSRP Inter frequency absolute accuracy Parameter Unit Accuracy [dB] Conditions1 Normal condition Extreme condition Bands 1, 4, 6, 10, 11, 18, 19, 21, 23, 24, 33, 34, 35, 36, 37, 38, 39, 40 Bands 2, 5, 7, 41 Band 25 Bands 3, 8, 12, 13, 14, 17, 20, 22 Bands 9, 42, 43 Io Io Io Io Io RSRP for Ês/Iot  -6 dB dBm 6 9 -121dBm/15kHz … -70dBm/ BWChannel -119dBm/15kHz … -70dBm/ BWChannel -117.5dBm/15kHz … -70dBm/ BWChannel -118dBm/15kHz … -70dBm/ BWChannel -120dBm/15kHz … -70dBm/ BWChannel RSRP for Ês/Iot  -6 dB dBm 8 11 -70dBm/ BWChannel … -50dBm/ BWChannel -70dBm/ BWChannel … -50dBm/ BWChannel -70dBm/ BWChannel … -50dBm/ BWChannel -70dBm/ BWChannel … -50dBm/ BWChannel -70dBm/ BWChannel … -50dBm/ BWChannel Note 1: Io is assumed to have constant EPRE across the bandwidth. The normative reference for this requirement is TS 25.123 [2] clauses 9.1.1.5a and A.9.2.5a.1.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.14.3 Test purpose
The purpose of this test is to verify that the E-UTRA FDD RSRP measurement absolute accuracy is within the specified limits. This test will verify the requirements in 8.7.14.2 and applies to UE supporting this capability.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.14.4 Method of test
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.14.4.1 Initial conditions
Test environment: normal, TL/VL, TL/VH, TH/VL, TH/VH; see clauses G.2.1 and G.2.2. Frequencies to be tested: see table J.2 in Annex J. In the test in Cell_DCH state, “E-UTRAN FDD RSRP Measurement” is applied to measure on E-UTRAN FDD. Tables 8.7.14.4.1-1 and 8.7.14.4.1-2 define the limits of signal strengths and code powers on the UTRA TDD cell. In the measurement control information periodic reporting of E-UTRAN FDD RSRP is indicated to the UE. The E-UTRAN FDD test parameters are given in Table 8.7.14.4.1-3. Table 8.7.14.4.1-1: General parameters of E-UTRA FDD RSRP measurement tests Parameter Unit Value Comment DCH parameters DL Reference Measurement Channel 12.2 kbps As specified in TS 25.102 section A.2.2 Power Control On Target quality value on DTCH BLER 0.01 Active cell Cell 1 1.28Mcps TDD cell Neighbour cell Cell 2 E-UTRA FDD cell CP length of cell 2 normal Idle intervals period ms 80 As specified in TS 25.331 Filter coefficient 0 L3 filtering is not used Inter-RAT(E-UTRA FDD) measurement quantity E-UTRA FDD RSRP Table 8.7.14.4.1-2: E-UTRA FDD RSRP measurement tests parameters (cell 1) Parameter Unit Test 1, Test 2 DL timeslot number 0 DwPTS UTRA RF Channel number (NOTE) Channel 1 PCCPCH_Ec/Ior dB -3 DwPCH_Ec/Ior dB 0 OCNS_Ec/Ior dB -3 Îor/Ioc dB 3 Ioc dBm / 1.28MHz -75 Propagation condition AWGN NOTE: In the case of multi-frequency, the UTRA RF Channel Number can be set for the primary frequency in this test. Table 8.7.14.4.1-3: E-UTRA FDD RSRP measurement tests parameters (cell 2) Parameter Unit Test 1 Test 2 E-UTRA RF Channel Number 1 1 BWchannel MHz 10 10 Measurement bandwidth 22—27 22—27 PDCCH/PCFICH/PHICH Reference measurement channel defined in A.2.1 in TS 36.521-3 [33] R.6 FDD R.6 FDD OCNG Patterns defined in D.1.2 (OP.2 FDD) in TS 36.521-3 [33] OP.2 FDD OP.2 FDD PBCH_RA dB 0 0 PBCH_RB PSS_RA SSS_RA PCFICH_RB PHICH_RA PHICH_RB PDCCH_RA PDCCH_RB PDSCH_RA PDSCH_RB OCNG_RANote1 OCNG_RBNote1 Note2 Bands 1, 4, 6,10, 11, 18, 19, 21, 23 and 24 dBm/15 kHz -88.65 -117 Bands 2, 5 and 7 -115 Band 25 -113.5 Bands 3, 8, 12, 13, 14, 17, 20 and 22 -114 Band 9 -116 dB 10 -4 RSRPNote3 Bands 1, 4, 6, 10, 11, 18, 19, 21, 23 and 24 dBm/15 kHz -78.65 -121 Bands 2, 5 and 7 -119 Band 25 -117.5 Bands 3, 8, 12, 13, 14, 17, 20 and 22 -118 Band 9 -120 IoNote3 Bands 1, 4, 6, 10, 11, 18, 19, 21, 23 and 24 dBm/9 MHz -50.45 -87.76 Bands 2, 5 and 7 -85.76 Band 25 -84.26 Bands 3, 8, 12, 13, 14, 17, 20 and 22 -84.76 Band 9 -86.76 dB 10 -4 Propagation condition - AWGN AWGN Note 1: OCNG shall be used such that both cells are fully allocated and a constant total transmitted power spectral density is achieved for all OFDM symbols. Note 2: Interference from other cells and noise sources not specified in the test is assumed to be constant over subcarriers and time and shall be modelled as AWGN of appropriate power for to be fulfilled. Note 3: RSRP and Io levels have been derived from other parameters for information purposes. They are not settable parameters themselves. Note 4: RSRP minimum requirements are specified assuming independent interference and noise at each receiver antenna port.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.14.4.2 Test Procedure
1) A call is set up according to the test procedure specified in TS 34.108 [3] clause 7.3.2. The RF parameters for Test 1 are set up according to table 8.7.14.5-2. 2) SS shall transmit the MEASUREMENT CONTROL message for inter RAT measurement. In the measurement control information periodic reporting of the EUTRAN FDD RSRP is requested to the UE. 3) UE shall transmit periodically MEASUREMENT REPORT messages. 4) SS shall check RSRP value of Cell 2 in the MEASUREMENT REPORT messages. Levels of Cell 2 reported by the UE are compared to the actual level of Cell 2 for each MEASUREMENT REPORT message. 5) SS shall check MEASUREMENT REPORT messages transmitted by UE until statistical significance according to Annex Tables G.2.3-1 in TS 36.521-3 [33] is achieved. 6) The RF parameters are set up according to tables 8.7.14.5-3 for Test 2. While RF parameters are being set up, MEASUREMENT REPORT messages from UE are ignored. SS shall wait for additional 5s and ignore the MEASUREMENT REPORT messages during this period. Then, step 4) and 5) above are repeated. 7) The SS shall transmit RRC CONNECTION RELEASE message. 8) UE shall transmit RRC CONNECTION RELEASE COMPLETE message. Specific Message Contents All messages indicated above shall use the same content as described in the default message content in clause 9 of 34.108 [3], with the following exceptions: NOTE: Numbers in brackets after an item e.g “Message Type (10.2.17)” in the IE description are references to clause numbers in TS 25.331 [9] describing that item in more detail. MEASUREMENT CONTROL message for EUTRAN FDD measurement (Step 1): Information Element Value/Remark Message Type (10.2.17) UE information elements -RRC transaction identifier -Integrity check info 0 Not Present Measurement Information elements -Measurement Identity -Measurement Command -Measurement Reporting Mode - Measurement Report Transfer Mode - Periodical Reporting / Event Trigger Reporting Mode -Additional measurement list -CHOICE Measurement Type -Inter-frequency measurement object list -CHOICE Inter-frequency cell removal -New inter-frequency cells -Cell for measurement -Inter-frequency measurement quantity -CHOICE reporting criteria -Filter coefficient -CHOICE mode -Measurement quantity -Inter-frequency reporting quantity -UTRA Carrier RSSI -Frequency quality estimate -Non frequency related cell reporting quantities -SFN-SFN observed time difference reporting indicator -Cell synchronisation information reporting indicator -Maximum number of reported cells -Measurement validity -Inter-frequency set update -CHOICE report criteria -Amount of reporting -Reporting interval 2 Setup Acknowledged mode RLC Periodical reporting Not Present Inter-RAT measurement Not Present Cell 2 information is included Not Present Inter-frequency reporting criteria 0 EUTRAN FDD RSRP FALSE FALSE No report Report all active set cells + cells within monitored set on used frequency Virtual/active set cells + 1 Not Present Not Present Periodical reporting criteria Infinity 500 ms Physical channel information elements -DPCH compressed mode status info Not Present
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.14.5 Test requirements
Table 8.7.14.5-2 and table 8.7.14.5-3 defines the primary level settings including test tolerances for all tests. For the test to pass, the ratio of successful reported values according to table 8.7.14.5-4 in each test shall be more than 90%, with a confidence level of 95%. Table 8.7.14.5-1: Void Table 8.7.14.5-2: UTRAN TDD cell specific test parameters for E-UTRAN FDD RSRP absolute accuracy tests Parameter Unit Test 1, Test 2 DL timeslot number 0 DwPTS UTRA RF Channel number (NOTE) Channel 1 PCCPCH_Ec/Ior dB -3 DwPCH_Ec/Ior dB 0 OCNS_Ec/Ior dB -3 Îor/Ioc dB 3 Ioc dBm / 1.28MHz -75 Propagation condition AWGN NOTE: In the case of multi-frequency, the UTRA RF Channel Number can be set for the primary frequency in this test. Table 8.7.14.5-3: E-UTRAN FDD cell specific test parameters for E-UTRAN FDD RSRP absolute accuracy tests Parameter Unit Test 1 Test 2 E-UTRA RF Channel Number 1 1 BWchannel MHz 10 10 Measurement bandwidth 22—27 22—27 PDCCH/PCFICH/PHICH Reference measurement channel defined in A.2.1 in TS 36.521-3 [33] R.6 FDD R.6 FDD OCNG Patterns defined in D.1.2 (OP.2 FDD) in TS 36.521-3 [33] OP.2 FDD OP.2 FDD PBCH_RA dB 0 0 PBCH_RB PSS_RA SSS_RA PCFICH_RB PHICH_RA PHICH_RB PDCCH_RA PDCCH_RB PDSCH_RA PDSCH_RB OCNG_RANote1 OCNG_RBNote1 Note2 Bands 1, 4, 6,10, 11, 18, 19, 21, 23 and 24 dBm/15 kHz -88.95 -117.00 Bands 2, 5 and 7 -115.00 Band 25 -113.50 Bands 3, 8, 12, 13, 14, 17, 20 and 22 -114.00 Band 9 -116.00 dB 10.00 -3.20 RSRPNote3 Bands 1, 4, 6, 10, 11, 18, 19, 21, 23 and 24 dBm/15 kHz -78.95 -120.20 Bands 2, 5 and 7 -118.20 Band 25 -116.70 Bands 3, 8, 12, 13, 14, 17, 20 and 22 -117.20 Band 9 -119.20 IoNote3 Bands 1, 4, 6, 10, 11, 18, 19, 21, 23 and 24 dBm/9 MHz -50.75 -87.52 Bands 2, 5 and 7 -85. 52 Band 25 -84.02 Bands 3, 8, 12, 13, 14, 17, 20 and 22 -84.52 Band 9 -86.52 dB 10.00 -3.20 Propagation condition - AWGN AWGN Note 1: OCNG shall be used such that both cells are fully allocated and a constant total transmitted power spectral density is achieved for all OFDM symbols. Note 2: Interference from other cells and noise sources not specified in the test is assumed to be constant over subcarriers and time and shall be modelled as AWGN of appropriate power for to be fulfilled. Note 3: RSRP and Io levels have been derived from other parameters for information purposes. They are not settable parameters themselves. Note 4: RSRP minimum requirements are specified assuming independent interference and noise at each receiver antenna port. Table 8.7.14.5-4: E-UTRAN FDD RSRP absolute accuracy requirements for the reported values Test 1 Test 2 All bands Bands 1, 4, 6, 10, 11 18, 19, 21, 23, 24 Bands 2, 5, 7 Band 25 Bands 3, 8, 12, 13, 14, 17, 20, 22 Band 9 Normal Conditions Lowest reported value (Cell 2) RSRP_52 RSRP_13 RSRP_15 RSRP_17 RSRP_16 RSRP_14 Highest reported value (Cell 2) RSRP_71 RSRP_28 RSRP_30 RSRP_31 RSRP_31 RSRP_29 Extreme Conditions Lowest reported value (Cell 2) RSRP_49 RSRP_10 RSRP_12 RSRP_14 RSRP_13 RSRP_11 Highest reported value (Cell 2) RSRP_74 RSRP_31 RSRP_33 RSRP_34 RSRP_34 RSRP_32 NOTE: If the above Test Requirement differs from the Minimum Requirement then the Test Tolerance applied for this test is non-zero. The Test Tolerance for this test is defined in clause F.2 and the explanation of how the Minimum Requirement has been relaxed by the Test Tolerance is given in clause F.4.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.7.15 E-UTRAN TDD RSRP
Editor’s note: This Test case is incomplete for frequencies above 3GHz • The Test system uncertainties applicable above 3GHz are undefined • The Test Tolerances and Test Requirements applicable above 3GHz are undefined