34.122
8.6.1.3.1.5 Test requirements
The number of Event 1G triggered measurement reports during time period T1 shall be less than 60. For the test to pass, the total number of successful tests shall be more than 90% with a confidence level of [FFS]% of the cases.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.1.3.2 1,28 Mcps TDD Option
Void.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.1.3.3 7,68 Mcps TDD Option
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.1.3.3.1 Definition and applicability
In the event triggered reporting, the measurement reporting delay is defined as the time between any event that will trigger a measurement report until the UE starts to transmit over the Uu interface. This requirement assumes that the measurement report is not delayed by other RRC signalling on the DCCH. This measurement reporting delay excludes a delay uncertainty resulted when inserting the measurement report to the TTI of the uplink DCCH. The delay uncertainty is twice the TTI of the uplink DCCH. The requirements and this test apply to the TDD (7,68 Mcps option) UE.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.1.3.3.2 Minimum requirement
The requirements are the same as in sub clause 8.6.1.1.2 The normative reference for this requirement is TS 25.123 [2] clauses , 8.1B.2.2.2 and A.8.1.3.3
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.1.3.3.3 Test purpose
To verify that the UE meets the minimum requirements and also verify that the UE performs sufficient layer 1 filtering of the measurements. The test is performed in fading propagation conditions.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.1.3.3.4 Method of test
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.1.3.3.4.1 Initial conditions
Test environment: normal; see clauses G.2.1 and G.2.2. Frequencies to be tested: mid range; see clause G.2.4. The test parameters are given in Tables 8.6.1.3.3.4.1.1 and 8.6.1.3.3.4.1.2. The test consists of one time period with time duration of T1. Two cells shall be present in the test, cell 1 being the current serving cell and cell 2 being a neighbour cell on the used frequency. Cell 1 and cell 2 shall be synchronised, i.e. share the same frame and timeslot timing. In the measurement control information it is indicated to the UE that event-triggered reporting with Event 1G shall be used, and that P-CCPCH RSCP shall be reported together with Event 1G. The DL DPCH shall be transmitted in timeslot 4 and the UL DPCH shall be transmitted in timeslot 12. The TTI of the UL DCCH shall be 20ms. Table 8.6.1.3.3.4.1.1: General test parameters for correct reporting of neighbours in fading propagation condition Parameter Unit Value Comment DCH parameters DL Reference Measurement Channel 12.2 kbps As specified in TS 25.102 section A.2.2 Power Control On Target quality value on DTCH BLER 0.01 Initial conditions Active cell Cell 1 Neighbour cell Cell 2 Final condition Active cell Cell 1 O dB 0 Cell individual offset. This value shall be used for all cells in the test. Hysteresis dB 0 Time to Trigger ms 200 Filter coefficient 0 Monitored cell list size 6 TDD neighbours on Channel 1 Sent before the beginning of time period T1 T1 s 200 Table 8.6.1.3.3.4.1.2: Cell specific test parameters for correct reporting of neighbours in fading propagation condition Parameter Unit Cell 1 Cell 2 T1 T1 T1 T1 DL timeslot number 0 8 0 8 UTRA RF Channel Number Channel 1 Channel 1 PCCPCH_Ec/Ior dB -3 n.a. -3 n.a. SCH_Ec/Ior dB -9 -9 -9 -9 SCH_toffset 0 0 2 2 PICH_Ec/Ior dB n.a. -3 n.a. -3 OCNS_Ec/Ior dB -3,12 -3,12 -3,12 -3,12 dB 7 7 2 2 PCCPCH RSCP dBm -66 n.a. -71 n.a. dBm/ 7,68 MHz -70 Propagation Condition Case 4 as specified in TS25.102 Annex B
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.1.3.3.4.2 Procedure
1) The RF parameters are set up according to T1. 2) The UE is switched on. 3) A call is set up according to the generic set-up procedure specified in TS 34.108 [3] subclause 7.4.2 to place the UE in CELL_DCH. 4) SS shall transmit a MEASUREMENT CONTROL message. 5) After 200 seconds from the beginning of T1, the UE is switched off. 6) Repeat steps 1-5 until the confidence level according to annex F.6.2 is achieved.. Specific Message Contents All messages indicated above shall use the same content as described in the default message content in clause 9 of 34.108 [3] with the following exceptions: MEASUREMENT CONTROL message (step 4): Information Element/Group name Value/Remark Message Type (10.2.17) UE information elements -RRC transaction identifier 0 -Integrity check info Not Present Measurement Information elements -Measurement Identity 1 -Measurement Command (10.3.7.46) Modify -Measurement Reporting Mode (10.3.7.49) -Measurement Report Transfer Mode AM RLC -Periodical Reporting / Event Trigger Reporting Mode Event trigger -Additional measurements list (10.3.7.1) Not Present -CHOICE Measurement type Intra-frequency measurement -Intra-frequency measurement (10.3.7.36) -Intra-frequency measurement objects list (10.3.7.33) Not Present -Intra-frequency measurement quantity (10.3.7.38) -Filter coefficient (10.3.7.9) 0 -CHOICE mode TDD -Measurement quantity list 1 -Measurement quantity Primary CCPCH -Intra-frequency reporting quantity (10.3.7.41) -Reporting quantities for active set cells (10.3.7.5) -SFN-SFN observed time difference reporting indicator No report -Cell synchronisation information reporting indicator FALSE -Cell Identity reporting indicator FALSE -CHOICE mode TDD -Timeslot ISCP reporting indicator FALSE -Primary CCPCH RSCP reporting indicator TRUE -Pathloss reporting indicator FALSE -Reporting quantities for monitored set cells (10.3.7.5) -SFN-SFN observed time difference reporting indicator No report -Cell synchronisation information reporting indicator FALSE -Cell Identity reporting indicator FALSE -CHOICE mode TDD -Timeslot ISCP reporting indicator FALSE -Proposed TGSN reporting required FALSE -Primary CCPCH RSCP reporting indicator TRUE -Pathloss reporting indicator FALSE -Reporting quantities for detected set cells (10.3.7.5) Not Present -Reporting cell status (10.3.7.61) -CHOICE reported cell Report all active set cells + cells within monitored set on used frequency -Maximum number of reported cells 1 -Measurement validity (10.3.7.51) Not Present -CHOICE report criteria Intra-frequency measurement reporting criteria -Intra-frequency measurement reporting criteria (10.3.7.39) -Parameters required for each event 1 -Intra-frequency event identity Event 1G -Triggering condition 2 Not Present -Reporting Range Constant Not Present -Cells forbidden to affect Reporting Range Not Present -W Not Present -Hysteresis 0 dB -Threshold used frequency Not Present -Reporting deactivation threshold Not Present -Replacement activation threshold Not Present -Time to trigger 0 ms -Amount of reporting Infinity -Reporting interval 0 ms (Note 1) -Reporting cell status Not Present Physical channel information elements -DPCH compressed mode status info (10.3.6.34) Not Present Note 1: Reporting interval = 0 ms means no periodical reporting
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.1.3.3.5 Test requirements
The number of Event 1G triggered measurement reports during time period T1 shall be less than 60. For the test to pass, the total number of successful tests shall be more than 90% with a confidence level of 95% of the cases.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.2 TDD inter frequency measurements
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.2.1 Correct reporting of neighbours in AWGN propagation condition
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.2.1.1 Definition and applicability
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.2.1.1.1 3,84 Mcps TDD Option
In the event triggered reporting period the measurement reporting delay is defined as the time between any event that will trigger a measurement report until the UE starts to transmit over the Uu interface. This requirement assumes that the measurement report is not delayed by other RRC signalling on the DCCH. This measurement reporting delay excludes a delay uncertainty resulted when inserting the measurement report to the TTI of the uplink DCCH. The delay uncertainty is twice the TTI of the uplink DCCH. The requirements and this test apply to the TDD (3,84 Mcps option) UE.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.2.1.1.2 1,28 Mcps TDD Option
The purpose of this test is to verify that the UE makes correct reporting of an event within the required times when doing inter frequency measurements on a neighbouring TDD cell. The test will partly verify the requirements in section 8.1A.2 and 9.1. of [2]. The requirements and this test apply to the TDD (1.28 Mcps option) UE.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.2.1.1.3 7,68 Mcps TDD Option
In the event triggered reporting period the measurement reporting delay is defined as the time between any event that will trigger a measurement report until the UE starts to transmit over the Uu interface. This requirement assumes that the measurement report is not delayed by other RRC signalling on the DCCH. This measurement reporting delay excludes a delay uncertainty resulted when inserting the measurement report to the TTI of the uplink DCCH. The delay uncertainty is twice the TTI of the uplink DCCH. The requirements and this test apply to the TDD (7,68 Mcps option) UE.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.2.1.2 Minimum requirement
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.2.1.2.1 3,84 Mcps TDD Option
When idle intervals are used for inter-frequency TDD measurements, the UE shall be able to identify a new detectable inter-frequency TDD cell belonging to the monitored set within If the UE does not require idle intervals to perform inter-frequency TDD measurements, the UE shall be able to identify a new detectable inter-frequency TDD cell belonging to the monitored set within 5000 ms. When idle intervals are used for TDD inter frequency measurements, the UE shall be capable of performing P-CCPCH RSCP measurements for Xmeasurement TDD inter inter-frequency TDD cells per TDD frequency of the monitored set. The UE physical layer shall be capable of reporting measurements to higher layers with measurement accuracy as specified in section 9 and with a measurement period of Tmeasurement inter. If the UE does not require idle intervals to perform TDD inter-frequency measurements, the measurement period for inter frequency P-CCPCH RSCP measurements shall be 480 ms. Where, Xmeasurement TDD inter = 6 (cells) Tmeasurement_period inter = 480 ms. The time period used for calculating the measurement period Tmeasurement_inter for inter frequency P-CCPCH RSCP measurements. NTDD inter: This is the available number of measurement opportunities for a Beacon timeslot of an inter-frequency TDD cell during the time period TTDD inter. The UE shall consider that a measurement opportunity on a Beacon timeslot of an inter-frequency TDD cell is provided if an idle interval of length equal to or greater than 3 timeslots less 2*0.5 ms implementation margin for frequency switching per idle interval completely overlaps in time with the Beacon timeslot of the inter-frequency TDD cell. Nbasic_identify_TDD inter = 80. This is a number of measurement opportunities for a Beacon timeslot of an inter-frequency TDD cell during the time period used in the inter frequency TDD equation where the maximum allowed time for the UE to identify a new detectable inter-frequency TDD cell is defined. Nbasic_measurement_TDD inter = 5. This is a number of measurement opportunities for a Beacon timeslot of an inter-frequency TDD cell during the time period TTDD inter used in the inter-frequency TDD equation where the measurement period for inter-frequency P-CCPCH RSCP measurements is defined. NFreq TDD: This is the number of TDD frequencies indicated in the inter frequency measurement control information. The event triggered measurement reporting delay, measured without L3 filtering shall be less than T identify inter defined in 25.123 [2]. When L3 filtering is used, an additional delay can be expected. The normative reference for this requirement is TS 25.123 [2] clauses 8.1.2.3.1, 8.1.2.3.2 and A.8.2.1
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.2.1.2.2 1,28 Mcps TDD Option
When idle intervals are used for inter-frequency TDD measurements, the UE shall be able to identify a new detectable cell belonging to the monitored set within when NInter: This is the minimum number of sub-frame in that the signal of P-CCPCH and DwPCH can be received for inter frequency target cell during the period TMeasurement_Period inter with an arbitrarily chosen timing. It depends on the channel allocation and is calculated by assuming 2*0.1ms for implementation margin (for the description of the idle intervals see Annex A of 25.225). Tbasic_identify_TDD,inter= 800ms. This is the time period used in the inter frequency equation where the maximum allowed time for the UE to identify a new TDD cell is defined. TMeasurement_Period Inter= 480 ms. The period used for calculating the measurement period Tmeasurement_inter for inter frequency P-CCPCH RSCP measurements. NFreq: Number of TDD frequencies indicated in the inter frequency measurement control information. If the UE does not require idle intervals to perform inter-frequency TDD measurements, the UE shall be able to identify a new detectable inter-frequency TDD cell belonging to the monitored set within 5000 ms. A cell shall be considered detectable when P-CCPCH Ec/Io > -8 dB and DwPCH_Ec/Io > -5 dB. When L3 filtering is used an additional delay can be expected. The test consist of 2 successive time periods, with a time duration T1 and T2. The test parameters are given in tables A.8.2C and A.8.2D below. Two cells shall be present in the test, cell 1 being the active cell and cell 2 being a 1.28Mcps TDD option neighbour cell on the unused frequency. In the measurement control information it is indicated to the UE that event-triggered reporting with Event 2C shall be used. P-CCPCH RSCP of the best cell on the unused frequency shall be reported together with Event 2C reporting. The measurement control message shall be sent to the UE such that the delay between the end of the last received TTI containing the message and the beginning of T1 is at least equal to the RRC procedure delay as defined in 25.331 [9]
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.2.1.2.3 7,68 Mcps TDD Option
When idle intervals are used for inter-frequency TDD measurements, the UE shall be able to identify a new detectable inter-frequency TDD cell belonging to the monitored set within If the UE does not require idle intervals to perform inter-frequency TDD measurements, the UE shall be able to identify a new detectable inter-frequency TDD cell belonging to the monitored set within 5000 ms. When idle intervals are used for TDD inter frequency measurements, the UE shall be capable of performing P-CCPCH RSCP measurements for Xmeasurement TDD inter inter-frequency TDD cells per TDD frequency of the monitored set. The UE physical layer shall be capable of reporting measurements to higher layers with measurement accuracy as specified in section 9 and with a measurement period of Tmeasurement inter. If the UE does not require idle intervals to perform TDD inter-frequency measurements, the measurement period for inter frequency P-CCPCH RSCP measurements shall be 480 ms. Where, Xmeasurement TDD inter = 6 (cells) Tmeasurement_period inter = 480 ms. The time period used for calculating the measurement period Tmeasurement_inter for inter frequency P-CCPCH RSCP measurements. NTDD inter: This is the available number of measurement opportunities for a Beacon timeslot of an inter-frequency TDD cell during the time period TTDD inter. The UE shall consider that a measurement opportunity on a Beacon timeslot of an inter-frequency TDD cell is provided if an idle interval of length equal to or greater than 3 timeslots less 2*0.5 ms implementation margin for frequency switching per idle interval completely overlaps in time with the Beacon timeslot of the inter-frequency TDD cell. Nbasic_identify_TDD inter = 80. This is a number of measurement opportunities for a Beacon timeslot of an inter-frequency TDD cell during the time period used in the inter frequency TDD equation where the maximum allowed time for the UE to identify a new detectable inter-frequency TDD cell is defined. Nbasic_measurement_TDD inter = 5. This is a number of measurement opportunities for a Beacon timeslot of an inter-frequency TDD cell during the time period TTDD inter used in the inter-frequency TDD equation where the measurement period for inter-frequency P-CCPCH RSCP measurements is defined. NFreq TDD: This is the number of TDD frequencies indicated in the inter frequency measurement control information. The event triggered measurement reporting delay, measured without L3 filtering shall be less than T identify inter defined in 25.123 [2]. When L3 filtering is used, an additional delay can be expected. The normative reference for this requirement is TS 25.123 [2] clauses 8.1B.2.3.1, 8.1B.2.3.2 and A.8.2.1
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.2.1.3 Test purpose
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.2.1.3.1 3,84 Mcps TDD Option
To verify that the UE meets the minimum requirement.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.2.1.3.2 1,28 Mcps TDD Option
To verify that the UE meets the minimum time requirements for identifying neighbouring TDD cells
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.2.1.3.3 7,68 Mcps TDD Option
To verify that the UE meets the minimum time requirements for identifying neighbouring interfrequency TDD cells.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.2.1.4 Method of test
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.2.1.4.1 3,84 Mcps TDD Option
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.2.1.4.1.1 Initial conditions
Test environment: normal; see clauses G.2.1 and G.2.2. Frequencies to be tested: mid range; see clause G.2.4. The test parameters are given in Table 8.6.2.1.1 and 8.6.2.1.2. The test consists of 2 successive time periods, with a time duration T1 and T2. Two cells shall be present in the test, cell 1 being the serving cell and cell 2 being a UTRA TDD neighbour cell on the unused frequency. All cells shall be synchronised, i.e. share the same frame and timeslot timing. In the measurement control information it is indicated to the UE that event-triggered reporting with Event 2C shall be used. P-CCPCH RSCP of the best cell on the unused frequency shall be reported together with Event 2C reporting. The Measurement control message shall be sent to the UE such that the delay between the end of the last received TTI containing the message and the beginning of T1 is at least equal to the RRC procedure delay as defined in [9]. The second Beacon timeslot shall be provided in timeslot 8 for both cell 1 and cell 2. The DL DPCH shall be transmitted in timeslot 1 and the UL DPCH shall be transmitted in timeslot 3. The TTI of the uplink DCCH shall be 20 ms. Table 8.6.2.1.1: General test parameters for Correct reporting of TDD inter-frequency neighbours in AWGN propagation condition (3,84 Mcps option) Parameter Unit Value Comment DPCH parameters DL Reference Measurement Channel 12.2 kbps As specified in Annex CTS 25.102 annex A.2.2 Power Control On Target quality value on DTCH BLER 0.01 Initial conditions Active cell Cell 1 UTRA TDD cell Neighbour cell Cell 2 UTRA TDD cell Threshold non used frequency dB -71 Applicable for event 2C Hysteresis dB 0 Applicable for event 2C Time to Trigger ms 0 Filter coefficient 0 Monitored cell list size 24 on channel 1 16 on channel 2 T1 s 10 T2 s 10 Table 8.6.2.1.2: Cell specific parameters for Correct reporting of TDD inter-frequency neighbours in AWGN propagation condition (3,84 Mcps option) Parameter Unit Cell 1 Cell 2 Timeslot Number 0 8 0 8 T1 T2 T1 T2 T1 T2 T1 T2 UTRA RF Channel Number Channel 1 Channel 2 PCCPCH_Ec/Ior dB -3 -3 -3 -3 SCH_Ec/Ior dB -9 -9 -9 -9 -9 -9 -9 -9 SCH_toffset 0 0 0 0 15 15 15 15 PICH_Ec/Ior -3 -3 -3 -3 OCNS -4,28 -4,28 -4,28 -4,28 -4,28 -4,28 -4,28 -4,28 dB 3 3 3 3 -Infinity 9 -Infinity 9 dBm/3,84 MHz -70 PCCPCH_RSCP dB -70 -70 -Infinity -64 Propagation Condition AWGN
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.2.1.4.1.2 Procedure
1) The RF parameters are set up according to T1. 2) The UE is switched on. 3) A call is set up according to the generic set-up procedure specified in TS 34.108 [3] subclause 7.4.2 to place the UE in CELL_DCH. 4) SS shall transmit a MEASUREMENT CONTROL message. 5) After 10 seconds from the beginning of T1, the SS shall switch the power settings from T1 to T2. 6) UE shall transmit a MEASUREMENT REPORT message triggered by event 2c for cell 2. The measurement reporting delay from the beginning of T2 shall be less than 5080 ms. If the UE fails to report the event within the required delay, then a failure is recorded. If the reporting delay for this event is within the required limit, the number of succesfull tests is increased by one. 7) After 10 seconds from the beginning of T3, the UE is switched off. Any timing information of cell 2 is deleted in the UE. 8) Repeat steps 1-7 [TBD] times. Specific Message Contents All messages indicated above shall use the same content as described in the default message content in clause 9 of 34.108 [3] with the following exceptions: NOTE: Numbers in brackets after an item e.g “Message Type (10.2.17)” in the IE description are references to clause numbers in TS 25.331 [9] describing that item in more detail.MEASUREMENT CONTROL message (step 4): Information Element/Group name Value/Remark Message Type (10.2.17) UE information elements -RRC transaction identifier 0 -Integrity check info Not Present Measurement Information elements -Measurement Identity 1 -Measurement Command (10.3.7.46) Modify -Measurement Reporting Mode (10.3.7.49) -Measurement Report Transfer Mode AM RLC -Periodical Reporting / Event Trigger Reporting Mode Event trigger -Additional measurements list (10.3.7.1) Not Present -CHOICE Measurement type Inter-frequency measurement -Inter-frequency measurement (10.3.7.16) -Inter-frequency measurement objects list (10.3.7.13) -CHOICE inter-frequency cell removal No inter-frequency cells removed -New inter-frequency cells 1 -Inter-frequency cell id 1 -Frequency info (10.3.6.36) -CHOICE mode TDD -UARFCN(Nt) Same frequency as channel 2 -Cell info (10.3.7.2) -Cell individual offset Not Present -Reference time difference to cell Not Present -Read SFN indicator False -CHOICE mode TDD -Primary CCPCH info (10.3.6.57) -CHOICE mode TDD -CHOICE TDD option 3,84 Mcps TDD -CHOICE Sync case 2 -Timeslot 0 -cell parameters ID Set to cell parameters ID of cell 2 -SCTD indicator FALSE -Primary CCPCH Tx power Set to Primary CCPCH Tx power of cell 2 as described in Table 8.6.2.1.2 -Timesllot list Not Present -Cell selection and re-selection info Not Present -Cell for measurement Not Present -Inter-frequency measurement quantity (10.3.7.18) -CHOICE reporting critera Inter-frequency reporting criteria -Filter coefficient (10.3.7.9) 0 -CHOICE mode TDD -Measurement quantity for frequency quality estimate Primary CCPCH RSCP -Inter-frequency reporting quantity (10.3.7.21) -UTRA carrier RSSI -Frequency quality estimate -Non frequency related cell reporting quantities (10.3.7.5) -SFN-SFN observed time difference reporting indicator No report -Cell synchronisation information reporting indicator FALSE -Cell identity reporting indicator FALSE -CHOICE mode TDD -Timeslot ISCP reporting indicator FALSE -Proposed TGSN Reporting required FALSE -Primary CCPCH RSCP reporting indicator TRUE -Pathloss reporting indicator FALSE -Reporting cell status (10.3.7.61) Not Present -Measurement validity (10.3.7.51) Not Present -CHOICE report criteria Inter-frequency measurement reporting criteria -Inter-frequency measurement reporting criteria (10.3.7.19) -Parameters required for each event 1 -Intra-frequency event identity Event 2C -Threshold used frequency Not Present -W Used frequency Not Present -Hysteresis 0 dB -Time to trigger 0 ms -Reporting Cell Status (10.3..61) -CHOICE reported cell Report cells within active and/or monitored set on used frequency or within virtual active and/or monitored set on non-used frequency -Maximum number of reported cells 3 -Parameters required for each non-used frequenc - Threshold non-used frequency -71 - W non-used frequency 1 Physical channel information elements -DPCH compressed mode status info (10.3.6.34) Not Present MEASUREMENT REPORT message (step 6) Information Element Value/remark Message Type (10.2.17) Integrity check info Not Present Measurement identity 1 Measured Results (10.3.7.44) -CHOICE Measurement Inter-frequency Measured results list -Inter-frequency measured results 1 -Frequency info -CHOICE mode TDD -UARFCN(Nt) Same frequency as channel 2 -UTRA carrier RSSI Not Present -Inter-frequency cell measured results 1 -Cell measured results (10.3.7.3) -Cell identity Not Present -SFN-SFN observed time difference Not Present -Cell synchronisation info Not Present -CHOICE mode TDD -Cell parameters ID Set to cell parameters ID of Cell 2 -Proposed TGSN Not Present -Primary CCPCH RSCP Checked that this IE is present -Pathloss Not Present -Timeslot list Not Present Measured results on RACH Not Present Additional measured results Not Present Event results (10.3.7.7) -CHOICE event result Inter-frequency measurement event results -Inter-frequency event identity 2C -Inter-frequency cells 1 -Frequency Info -CHOICE mode TDD -UARFCN(Nt) Same frequency as channel 2 -CHOICE mode TDD -Primary CCPCH Info -CHOICE mode TDD -CHOICE TDD Option 3,84 Mcps TDD -CHOICE Sync Case Not Present -Cell Parameters ID Set to cell parameters ID of Cell 2 -SCTD Indicator FALSE
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.2.1.4.2 1,28 Mcps TDD Option
Test environment : normal; see clauses G.2.1 and G.2.2. Frequencies to be tested : mid range ;see clauses G.2.4. Cell 1 is the active cell, Cell 2 is a neighbour cell on the unused frequency. The power level on Cell 1 is kept constant and the power level of Cell 2 is changed using "change of best cell event". General test parameters are given in the table 8.6.2.1.3 below and they are signalled from test device. In the measurement control information it is indicated to the UE that event-triggered reporting with Event 2C shall be used. P-CCPCH RSCP of the best cell has to be reported together with Event 2C reporting. New measurement control information, which defines neighbour cells etc., is always sent before the event starts. The cell specific test parameters are shown in Table 8.6.2.1.4. Table 8.6.2.1.3: General test parameters for correct reporting of TDD inter frequency neighbours in AWGN propagation condition 1,28Mcps option Parameter Unit Value Comment DPCH parameters active cell DL and UL Reference Measurement Channel 12.2 kbps As specified in TS 25.102 section A.2.2. The DPCH is located in an other timeslot than 0 Power Control On Target quality value on DTCH BLER 0.01 Initial conditions Active cell Cell 1 1.28Mcps TDD cell Neighbour cell Cell 2 1.28Mcps TDD cell Final condtions Active cell Cell 1 Threshold non used frequency dBm -71 Absolute P-CCPCH RSCP threshold for event 2C W non-used frequency 1 Applicable for event 2C Hysteresis dB 0 Time to Trigger ms 0 Filter coefficient 0 Monitored cell list size 24 on channel 1 16 on channel 2 Measurement control information is sent before T1 starts. T1 s 10 T2 s 10 Table 8.6.2.1.4 Cell Specific Parameters for Correct Reporting of Neighbours in AWGN Propagation Condition 1,28Mcps option Parameter Unit Cell 1 Cell 2 Timeslot Number 0 DwPTS 0 DwPTS T1 T2 T1 T2 T1 T2 T1 T2 UTRA RF Channel Number Channel 1 Channel 2 PCCPCH_Ec/Ior dB -3 -3 DwPCH_Ec/Ior dB 0 0 OCNS_Ec/Ior dB -3 -3 dB 3 3 -Infinity 8 dBm/1.28 MHz -70 PCCPCH_RSCP dBm -70 -70 -Infinity -65 Propagation Condition AWGN NOTE: The DPCH of all cells are located in a timeslot other than 0. 8.6.2.1.4.2.2 Test Procedure 1) The RF parameters are set up according to T1. 2) The UE is switched on. 3) A call is set up according to the generic set-up procedure specified in TS 34.108 [3] subclause 7.4.2 to place the UE in CELL_DCH. 4) SS shall transmit a MEASUREMENT CONTROL message. 5) After 10 seconds from the beginning of T1, the SS shall switch the power settings from T1 to T2. 6) UE shall transmit a MEASUREMENT REPORT message triggered by event 2c for cell 2. The measurement reporting delay from the beginning of T2 shall be less than 5080 ms. If the UE fails to report the event within the required delay, then a failure is recorded. If the reporting delay for this event is within the required limit, the number of succesfull tests is increased by one. 7) After 10 seconds from the beginning of T2, the UE is switched off. Any timing information of cell 2 is deleted in the UE. 8) Repeat steps 1-7 until the confidence level according to annex F.6.2 is achieved. Specific Message Contents All messages indicated above shall use the same content as described in the default message content in clause 9 of 34.108 [3] and in Annex A of 34.123-1 [21], with the following exceptions: Note: Numbers in brackets after an item e.g “Message Type (10.2.17)” in the IE description are references to clause numbers in TS 25.331 [9] describing that item in more detail. MEASUREMENT CONTROL message (step 4): Information Element/Group name Value/Remark Message Type (10.2.17) UE information elements -RRC transaction identifier 0 -Integrity check info Not Present Measurement Information elements -Measurement Identity 1 -Measurement Command (10.3.7.46) Modify -Measurement Reporting Mode (10.3.7.49) -Measurement Report Transfer Mode AM RLC -Periodical Reporting / Event Trigger Reporting Mode Event trigger -Additional measurements list (10.3.7.1) Not Present -CHOICE Measurement type Inter-frequency measurement -Inter-frequency measurement (10.3.7.16) -Inter-frequency measurement objects list (10.3.7.13) -CHOICE inter-frequency cell removal No inter-frequency cells removed -New inter-frequency cells 1 -Inter-frequency cell id 1 -Frequency info (10.3.6.36) -CHOICE mode TDD -UARFCN(Nt) Same frequency as channel 2 -Cell info (10.3.7.2) -Cell individual offset Not Present -Reference time difference to cell Not Present -Read SFN indicator False -CHOICE mode TDD -Primary CCPCH info (10.3.6.57) -CHOICE mode TDD -CHOICE TDD option 1,28 Mcps TDD -cell parameters ID Set to cell parameters ID of cell 2 -SCTD indicator FALSE -Primary CCPCH Tx power Set to Primary CCPCH Tx power of cell 2 as described in Table 8.6.2.1.2 -Timesllot list Not Present -Cell selection and re-selection info Not Present -Cell for measurement Not Present -Inter-frequency measurement quantity (10.3.7.18) -CHOICE reporting critera Inter-frequency reporting criteria -Filter coefficient (10.3.7.9) 0 -CHOICE mode TDD -Measurement quantity for frequency quality estimate Primary CCPCH RSCP -Inter-frequency reporting quantity (10.3.7.21) -UTRA carrier RSSI FALSE -Frequency quality estimate FALSE -Non frequency related cell reporting quantities (10.3.7.5) -SFN-SFN observed time difference reporting indicator No report -Cell synchronisation information reporting indicator FALSE -Cell identity reporting indicator FALSE -CHOICE mode TDD -Timeslot ISCP reporting indicator FALSE -Proposed TGSN Reporting required FALSE -Primary CCPCH RSCP reporting indicator TRUE -Pathloss reporting indicator FALSE -Reporting cell status (10.3.7.61) Not Present -Measurement validity (10.3.7.51) Not Present -CHOICE report criteria Inter-frequency measurement reporting criteria -Inter-frequency measurement reporting criteria (10.3.7.19) -Parameters required for each event 1 -Intra-frequency event identity Event 2C -Threshold used frequency Not Present -W Used frequency Not Present -Hysteresis 0 dB -Time to trigger 0 ms -Reporting Cell Status (10.3..61) -CHOICE reported cell Report cells within active and/or monitored set on used frequency or within virtual active and/or monitored set on non-used frequency -Maximum number of reported cells 3 -Parameters required for each non-used frequenc - Threshold non-used frequency -71 - W non-used frequency 1 Physical channel information elements -DPCH compressed mode status info (10.3.6.34) Not Present MEASUREMENT REPORT message (step 6) Information Element Value/remark Message Type (10.2.17) Integrity check info Not Present Measurement identity 1 Measured Results (10.3.7.44) -CHOICE Measurement Inter-frequency Measured results list -Inter-frequency measured results 1 -Frequency info -CHOICE mode TDD -UARFCN(Nt) Same frequency as channel 2 -UTRA carrier RSSI Not Present -Inter-frequency cell measured results 1 -Cell measured results (10.3.7.3) -Cell identity Not Present -SFN-SFN observed time difference Not Present -Cell synchronisation info Not Present -CHOICE mode TDD -Cell parameters ID Set to cell parameters ID of Cell 2 -Proposed TGSN Not Present -Primary CCPCH RSCP Checked that this IE is present -Pathloss Not Present -Timeslot list Not Present Measured results on RACH Not Present Additional measured results Not Present Event results (10.3.7.7) -CHOICE event result Inter-frequency measurement event results -Inter-frequency event identity 2C -Inter-frequency cells 1 -Frequency Info -CHOICE mode TDD -UARFCN(Nt) Same frequency as channel 2 -Non frequency related measurement event results -CHOICE mode TDD -Primary CCPCH Info -CHOICE mode TDD -CHOICE TDD Option 1.28 Mcps TDD -TSTD indicator TRUE -Cell Parameters ID Set to cell parameters ID of Cell 2 -SCTD Indicator FALSE
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.2.1.4.3 7,68 Mcps TDD Option
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.2.1.4.3.1 Initial conditions
Test environment: normal; see clauses G.2.1 and G.2.2. Frequencies to be tested: mid range; see clause G.2.4. The test parameters are given in Table 8.6.2.1.4.3.1.1 and 8.6.2.1.4.3.1.2. The test consists of 2 successive time periods, with a time duration T1 and T2. Two cells shall be present in the test, cell 1 being the serving cell and cell 2 being a UTRA TDD neighbour cell on the unused frequency. All cells shall be synchronised, i.e. share the same frame and timeslot timing. In the measurement control information it is indicated to the UE that event-triggered reporting with Event 2C shall be used. P-CCPCH RSCP of the best cell on the unused frequency shall be reported together with Event 2C reporting. The Measurement control message shall be sent to the UE such that the delay between the end of the last received TTI containing the message and the beginning of T1 is at least equal to the RRC procedure delay as defined in [9]. The second Beacon timeslot shall be provided in timeslot 8 for both cell 1 and cell 2. The DL DPCH shall be transmitted in timeslot 1 and the UL DPCH shall be transmitted in timeslot 3. The TTI of the uplink DCCH shall be 20 ms. Table 8.6.2.1.4.3.1.1: General test parameters for Correct reporting of TDD inter-frequency neighbours in AWGN propagation condition (7,68 Mcps option) Parameter Unit Value Comment DPCH parameters DL Reference Measurement Channel 12.2 kbps As specified in TS 25.102 annex A.2.2 Power Control On Target quality value on DTCH BLER 0.01 Initial conditions Active cell Cell 1 UTRA TDD cell Neighbour cell Cell 2 UTRA TDD cell Threshold non used frequency dB -71 Applicable for event 2C Hysteresis dB 0 Applicable for event 2C Time to Trigger ms 0 Filter coefficient 0 Monitored cell list size 24 on channel 1 16 on channel 2 T1 s 10 T2 s 10 Table 8.6.2.1.4.3.1.2: Cell specific parameters for Correct reporting of TDD inter-frequency neighbours in AWGN propagation condition (7,68 Mcps option) Parameter Unit Cell 1 Cell 2 Timeslot Number 0 8 0 8 T1 T2 T1 T2 T1 T2 T1 T2 UTRA RF Channel Number Channel 1 Channel 2 PCCPCH_Ec/Ior dB -3 -3 -3 -3 SCH_Ec/Ior dB -9 -9 -9 -9 -9 -9 -9 -9 SCH_toffset 0 0 0 0 15 15 15 15 PICH_Ec/Ior -3 -3 -3 -3 OCNS -4,28 -4,28 -4,28 -4,28 -4,28 -4,28 -4,28 -4,28 dB 3 3 3 3 -Infinity 9 -Infinity 9 dBm/7.68 MHz -70 PCCPCH_RSCP dB -70 -70 -Infinity -64 Propagation Condition AWGN
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.2.1.4.3.2 Procedure
1) The RF parameters are set up according to T1. 2) The UE is switched on. 3) A call is set up according to the generic set-up procedure specified in TS 34.108 [3] subclause 7.4.2 to place the UE in CELL_DCH. 4) SS shall transmit a MEASUREMENT CONTROL message. 5) After 10 seconds from the beginning of T1, the SS shall switch the power settings from T1 to T2. 6) UE shall transmit a MEASUREMENT REPORT message triggered by event 2c for cell 2. The measurement reporting delay from the beginning of T2 shall be less than 5080 ms. If the UE fails to report the event within the required delay, then a failure is recorded. If the reporting delay for this event is within the required limit, the number of succesfull tests is increased by one. 7) After 10 seconds from the beginning of T3, the UE is switched off. Any timing information of cell 2 is deleted in the UE. 8) Repeat steps 1-7 until the confidence level according to annex F.6.2 is achieved.. Specific Message Contents All messages indicated above shall use the same content as described in the default message content in clause 9 of 34.108 [3] with the following exceptions: Note: Numbers in brackets after an item e.g “Message Type (10.2.17)” in the IE description are references to clause numbers in TS 25.331 [9] describing that item in more detail.MEASUREMENT CONTROL message (step 4): Information Element/Group name Value/Remark Message Type (10.2.17) UE information elements -RRC transaction identifier 0 -Integrity check info Not Present Measurement Information elements -Measurement Identity 1 -Measurement Command (10.3.7.46) Modify -Measurement Reporting Mode (10.3.7.49) -Measurement Report Transfer Mode AM RLC -Periodical Reporting / Event Trigger Reporting Mode Event trigger -Additional measurements list (10.3.7.1) Not Present -CHOICE Measurement type Inter-frequency measurement -Inter-frequency measurement (10.3.7.16) -Inter-frequency measurement objects list (10.3.7.13) -CHOICE inter-frequency cell removal No inter-frequency cells removed -New inter-frequency cells 1 -Inter-frequency cell id 1 -Frequency info (10.3.6.36) -CHOICE mode TDD -UARFCN(Nt) Same frequency as channel 2 -Cell info (10.3.7.2) -Cell individual offset Not Present -Reference time difference to cell Not Present -Read SFN indicator False -CHOICE mode TDD -Primary CCPCH info (10.3.6.57) -CHOICE mode TDD -CHOICE TDD option 7,68 Mcps TDD -CHOICE Sync case 2 -Timeslot 0 -cell parameters ID Set to cell parameters ID of cell 2 -SCTD indicator FALSE -Primary CCPCH Tx power Set to Primary CCPCH Tx power of cell 2 as described in Table 8.6.2.1.2 -Timesllot list Not Present -Cell selection and re-selection info Not Present -Cell for measurement Not Present -Inter-frequency measurement quantity (10.3.7.18) -CHOICE reporting critera Inter-frequency reporting criteria -Filter coefficient (10.3.7.9) 0 -CHOICE mode TDD -Measurement quantity for frequency quality estimate Primary CCPCH RSCP -Inter-frequency reporting quantity (10.3.7.21) -UTRA carrier RSSI -Frequency quality estimate -Non frequency related cell reporting quantities (10.3.7.5) -SFN-SFN observed time difference reporting indicator No report -Cell synchronisation information reporting indicator FALSE -Cell identity reporting indicator FALSE -CHOICE mode TDD -Timeslot ISCP reporting indicator FALSE -Proposed TGSN Reporting required FALSE -Primary CCPCH RSCP reporting indicator TRUE -Pathloss reporting indicator FALSE -Reporting cell status (10.3.7.61) Not Present -Measurement validity (10.3.7.51) Not Present -CHOICE report criteria Inter-frequency measurement reporting criteria -Inter-frequency measurement reporting criteria (10.3.7.19) -Parameters required for each event 1 -Intra-frequency event identity Event 2C -Threshold used frequency Not Present -W Used frequency Not Present -Hysteresis 0 dB -Time to trigger 0 ms -Reporting Cell Status (10.3..61) -CHOICE reported cell Report cells within active and/or monitored set on used frequency or within virtual active and/or monitored set on non-used frequency -Maximum number of reported cells 3 -Parameters required for each non-used frequenc - Threshold non-used frequency -71 - W non-used frequency 1 Physical channel information elements -DPCH compressed mode status info (10.3.6.34) Not Present MEASUREMENT REPORT message (step 6) Information Element Value/remark Message Type (10.2.17) Integrity check info Not Present Measurement identity 1 Measured Results (10.3.7.44) -CHOICE Measurement Inter-frequency Measured results list -Inter-frequency measured results 1 -Frequency info -CHOICE mode TDD -UARFCN(Nt) Same frequency as channel 2 -UTRA carrier RSSI Not Present -Inter-frequency cell measured results 1 -Cell measured results (10.3.7.3) -Cell identity Not Present -SFN-SFN observed time difference Not Present -Cell synchronisation info Not Present -CHOICE mode TDD -Cell parameters ID Set to cell parameters ID of Cell 2 -Proposed TGSN Not Present -Primary CCPCH RSCP Checked that this IE is present -Pathloss Not Present -Timeslot list Not Present Measured results on RACH Not Present Additional measured results Not Present Event results (10.3.7.7) -CHOICE event result Inter-frequency measurement event results -Inter-frequency event identity 2C -Inter-frequency cells 1 -Frequency Info -CHOICE mode TDD -UARFCN(Nt) Same frequency as channel 2 -CHOICE mode TDD -Primary CCPCH Info -CHOICE mode TDD -CHOICE TDD Option 7,68 Mcps TDD -CHOICE Sync Case Not Present -Cell Parameters ID Set to cell parameters ID of Cell 2 -SCTD Indicator FALSE
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.2.1.5 Test requirements
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.2.1.5.1 3,84 Mcps TDD Option
The UE shall send one Event 2C triggered measurement report for Cell 2 with a measurement reporting delay less than 5080ms from the beginning of time period T2. The UE shall not send event triggered measurement reports, as long as the reporting criteria are not fulfilled. For the test to pass, the total number of successful tests shall be more than 90% with a confidence level of [FFS]% of the cases.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.2.1.5.2 1,28 Mcps TDD Option
The UE shall send an EVENT 2C message of cell 2 within 5080ms from the beginning of the time T2 The UE shall not send any event triggered measurement reports, as long as the reporting criteria are not fulfilled. For the test to pass, the total number of successful tests shall be more than 90% with a confidence level of 95% of the cases.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.2.1.5.3 7,68 Mcps TDD Option
The UE shall send one Event 2C triggered measurement report for Cell 2 with a measurement reporting delay less than 5080ms from the beginning of time period T2. The UE shall not send event triggered measurement reports, as long as the reporting criteria are not fulfilled. For the test to pass, the total number of successful tests shall be more than 90% with a confidence level of 95% of the cases.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.3 FDD measurements
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.3.1 Correct reporting of FDD neighbours in AWGN propagation condition
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.3.1.1 Definition and applicability
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.3.1.1.1 3,84 Mcps TDD Option
In the event triggered reporting period the measurement reporting delay is defined as the time between any event that will trigger a measurement report until the UE starts to transmit over the Uu interface. This requirement assumes that the measurement report is not delayed by other RRC signalling on the DCCH. This measurement reporting delay excludes a delay uncertainty resulted when inserting the measurement report to the TTI of the uplink DCCH. The delay uncertainty is twice the TTI of the uplink DCCH. The requirements and this test apply to the combined FDD and TDD (3,84 Mcps option) UE.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.3.1.1.2 1,28 Mcps TDD Option
The purpose of this test is to verify that the UE makes correct reporting of an event when measuring on UTRA FDD cells. This test will partly verify the requirements in section 8.1A.2 and 9.1. of [2] The test consists of two successive time periods, with a time duration T1 and T2. Two cells shall be present in the test, cell 1 being current active 1.28Mcps TDD cell and cell 2 being a UTRA FDD neighbouring cell. In the measurement control information it is indicated to the UE hat event-triggered reporting with Event 2C shall be used and the CPICH RSCP of the best cell on the unused frequency shall be reported together with Event 2C.The measurement control message shall be sent to the UE such that the delay between the end of the last received TTI containing the message and the beginning of T1 is at least equal to the RRC procedure delay as defined in 25.331 [9]. The requirements and this test apply to all types of 1.28 Mcps TDD UE.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.3.1.1.3 7,68 Mcps TDD Option
In the event triggered reporting period the measurement reporting delay is defined as the time between any event that will trigger a measurement report until the UE starts to transmit over the Uu interface. This requirement assumes that the measurement report is not delayed by other RRC signalling on the DCCH. This measurement reporting delay excludes a delay uncertainty resulted when inserting the measurement report to the TTI of the uplink DCCH. The delay uncertainty is twice the TTI of the uplink DCCH. The requirements and this test apply to the combined FDD and TDD (7,68 Mcps option) UE.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.3.1.2 Minimum requirement
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.3.1.2.1 3,84 Mcps TDD Option
When idle intervals are used for inter-frequency FDD measurements, the UE shall be able to identify a new detectable inter-frequency FDD cell belonging to the monitored set within If the UE does not require idle intervals to perform FDD inter-frequency measurements, the UE shall be able to identify a new detectable inter-frequency FDD cell belonging to the monitored set within 5000 ms. When L3 filtering is used an additional delay can be expected. An inter-frequency FDD cell shall be considered detectable, when CPICH Ec/Io > -20 dB, SCH_Ec/Io > -17 dB and SCH_Ec/Ior is equally divided between primary synchronisation code and secondary synchronisation code. When idle intervals are used for FDD inter frequency measurements, the UE physical layer shall be capable of reporting measurements to higher layers with measurement period given by If the UE does not require idle intervals to perform FDD inter-frequency measurements, the measurement period for inter frequency CPICH measurements shall be 480 ms. The UE shall be capable of performing CPICH measurements for Xmeasurement FDD inter inter-frequency FDD cells per frequency of the monitored set and the UE physical layer shall be capable of reporting measurements to higher layers with the measurement period of Tmeasurement FDD inter. Xbasic measurement FDD inter = 6 (cells) Tmeasurement_period FDD inter = 480 ms. The time period used for calculating the measurement period Tmeasurement_FDD inter for inter frequency CPICH measurements. TFDD inter: available: This is the available time for measurements on inter-frequency FDD cells. TFDD inter available shall be derived from TFDD inter by assuming 2*0.5 ms implementation margin for frequency switching per idle interval and by only taking into account the remaining number of full timeslots per idle interval. Idle intervals smaller than 3 timeslots shall not be taken into account for calculating TFDD inter available. Tbasic_identify_FDD inter = 800 ms. This is the time period used in the inter frequency equation where the maximum allowed time for the UE to identify a new detectable inter-frequency FDD cell is defined. Tbasic_measurement_FDD inter = 50 ms. This is the time period used in the inter-frequency equation for defining the measurement period for inter frequency CPICH measurements. NFreq: This is the number of FDD frequencies indicated in the inter frequency measurement control information. The event triggered measurement reporting delay, measured without L3 filtering shall be less than T identify inter defined in 25.123 [2]. When L3 filtering is used, an additional delay can be expected. The normative reference for this requirement is TS 25.123 [2] clauses 8.1.2.4 and A.8.3.1
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.3.1.2.2 1,28 Mcps TDD Option
The UE shall send the Event 2C triggered measurement report, with a measurement reporting delay less than 5.08 s from the beginning of time period T2.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.3.1.2.3 7,68 Mcps TDD Option
When idle intervals are used for inter-frequency FDD measurements, the UE shall be able to identify a new detectable inter-frequency FDD cell belonging to the monitored set within If the UE does not require idle intervals to perform FDD inter-frequency measurements, the UE shall be able to identify a new detectable inter-frequency FDD cell belonging to the monitored set within 5000 ms. When L3 filtering is used an additional delay can be expected. An inter-frequency FDD cell shall be considered detectable, when CPICH Ec/Io > -20 dB, SCH_Ec/Io > -17 dB and SCH_Ec/Ior is equally divided between primary synchronisation code and secondary synchronisation code. When idle intervals are used for FDD inter frequency measurements, the UE physical layer shall be capable of reporting measurements to higher layers with measurement period given by If the UE does not require idle intervals to perform FDD inter-frequency measurements, the measurement period for inter frequency CPICH measurements shall be 480 ms. The UE shall be capable of performing CPICH measurements for Xmeasurement FDD inter inter-frequency FDD cells per frequency of the monitored set and the UE physical layer shall be capable of reporting measurements to higher layers with the measurement period of Tmeasurement FDD inter. Xbasic measurement FDD inter = 6 (cells) Tmeasurement_period FDD inter = 480 ms. The time period used for calculating the measurement period Tmeasurement_FDD inter for inter frequency CPICH measurements. TFDD inter: available: This is the available time for measurements on inter-frequency FDD cells. TFDD inter available shall be derived from TFDD inter by assuming 2*0.5 ms implementation margin for frequency switching per idle interval and by only taking into account the remaining number of full timeslots per idle interval. Idle intervals smaller than 3 timeslots shall not be taken into account for calculating TFDD inter available. Tbasic_identify_FDD inter = 800 ms. This is the time period used in the inter frequency equation where the maximum allowed time for the UE to identify a new detectable inter-frequency FDD cell is defined. Tbasic_measurement_FDD inter = 50 ms. This is the time period used in the inter-frequency equation for defining the measurement period for inter frequency CPICH measurements. NFreq: This is the number of FDD frequencies indicated in the inter frequency measurement control information. The event triggered measurement reporting delay, measured without L3 filtering shall be less than T identify inter defined in 25.123 [2]. When L3 filtering is used, an additional delay can be expected. The normative reference for this requirement is TS 25.123 [2] clauses 8.1B.2.4 and A.8.3.1
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.3.1.3 Test purpose
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.3.1.3.1 3,84 Mcps TDD Option
To verify that the UE meets the minimum requirement.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.3.1.3.2 1,28 Mcps TDD Option
To verify that the UE meets the minimum time requirements for identifying neighbouring FDD cells.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.3.1.3.3 7,68 Mcps TDD Option
To verify that the UE meets the minimum time requirements for identifying neighbouring FDD cells.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.3.1.4 Method of test
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.3.1.4.1 3,84 Mcps TDD Option
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.3.1.4.1.1 Initial conditions
Test environment: normal; see clauses G.2.1 and G.2.2. Frequencies to be tested: mid range; see clause G.2.4. The test parameters are given in Table 8.6.3.1.1 and 8.6.3.1.2. The test consists of two successive time periods, with time durations of T1 and T2 respectively. Two cells shall be present in the test, cell 1 being the serving UTRA TDD cell and cell 2 being a UTRA FDD neighbour cells on the unused frequency. In the measurement control information it is indicated to the UE that event-triggered reporting with Event 2C shall be used and that CPICH Ec/I0 of the best cell on the unused frequency shall be reported together with Event 2C. The Measurement control message shall be sent to the UE such that the delay between the end of the last received TTI containing the message and the beginning of T1 is at least equal to the RRC procedure delay as defined in [9]. The second Beacon timeslot shall be provided in timeslot 8 for cell 1. The DL DPCH shall be transmitted in timeslot 1 and the UL DPCH shall be transmitted in timeslot 3. The TTI of the uplink DCCH shall be 20 ms. Table 8.6.3.1.1: General test parameters for Correct reporting of FDD inter-frequency neighbours in AWGN propagation condition (3,84 Mcps option) Parameter Unit Value Comment DPCH parameters DL Reference Measurement Channel 12.2 kbps As specified in TS 25.102 section A.2.2 Power Control On Target quality value on DTCH BLER 0.01 Initial conditions Active cell Cell 1 UTRA TDD cell Neighbour cell Cell 2 UTRA FDD cell Final conditions Active cell Cell 1 Threshold non used frequency dB -18 Applicable for event 2C W non-used frequency 1 Applicable for event 2C Hysteresis dB 0 Applicable for event 2C Time to Trigger ms 0 Filter coefficient 0 Monitored cell list size 6 TDD neighbours on channel 1 6 FDD neighbours on channel 2 T1 s 15 T2 s 10 Table 8.6.3.1.2: Cell specific parameters for Correct reporting of FDD inter-frequency neighbours in AWGN propagation condition (3,84 Mcps option) Parameter Unit Cell 1 Cell 2 Timeslot Number 0 8 n.a T1 T2 T1 T2 T1 T2 UTRA RF Channel Number Channel 1 Channel 2 CPICH_Ec/Ior dB n.a. n.a. -10 PCCPCH_Ec/Ior dB -3 -3 -12 SCH_Ec/Ior dB -9 -9 -9 -9 -12 SCH_toffset 0 0 0 0 n.a. PICH_Ec/Ior -3 -3 -15 OCNS dB -4,28 -4,28 -4,28 -4,28 -0,941 dB 3 3 3 3 -infinity -1.8 dBm/ 3,84 MHz -70 -70 CPICH_Ec/Io n.a. -infinity -14 PCCPCH_RSCP dB -70 -70 -70 -70 n.a. Propagation Condition AWGN AWGN
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.3.1.4.1.2 Procedure
1) The RF parameters are set up according to T1. 2) The UE is switched on. 3) A call is set up according to the generic set-up procedure specified in TS 34.108 [3] subclause 7.4.2 to place the UE in CELL_DCH. 4) SS shall transmit a MEASUREMENT CONTROL message. 5) After 15 seconds from the beginning of T1, the SS shall switch the power settings from T1 to T2. 6) UE shall transmit a MEASUREMENT REPORT message triggered by event 2C for cell 2. The measurement reporting delay from the beginning of T2 shall be less than 5040 ms. If the UE fails to report the event within the required delay, then a failure is recorded. If the reporting delay for this event is within the required limit, the number of succesfull tests is increased by one. 7) After 10 seconds from the beginning of T2, the UE is switched off. Any timing information of cell 2 is deleted in the UE. 8) Repeat steps 1-7 [TBD] times. Specific Message Contents All messages indicated above shall use the same content as described in the default message content in clause 9 of 34.108 [3] with the following exceptions: Note: 10.x.y.z in the IE description refers to clauses in TS 25.331 [9]. MEASUREMENT CONTROL message (step 4): Information Element/Group name Value/Remark Message Type (10.2.17) UE information elements -RRC transaction identifier 0 -Integrity check info Not Present Measurement Information elements -Measurement Identity 1 -Measurement Command (10.3.7.46) Modify -Measurement Reporting Mode (10.3.7.49) -Measurement Report Transfer Mode AM RLC -Periodical Reporting / Event Trigger Reporting Mode Event trigger -Additional measurements list (10.3.7.1) Not Present -CHOICE Measurement type Inter-frequency measurement -Inter-frequency measurement (10.3.7.16) -Inter-frequency measurement objects list (10.3.7.13) -CHOICE inter-frequency cell removal No inter-frequency cells removed -New inter-frequency cells 1 -Inter-frequency cell id 1 -Frequency info (10.3.6.36) -CHOICE mode FDD -UARFCN uplink (Nu) Not Present -UARFCN downlink (Nd) Same frequency as channel 2 -Cell info (10.3.7.2) -Cell individual offset Not Present -Reference time difference to cell Not Present -Read SFN indicator False -CHOICE mode FDD -Primary CPICH info -Primary scrambling code Set to Primary scrambling code of Cell2 -Primary CPICH Tx Power Set to Primary CPICH Tx Power of Cell2 described in Table 8.6.3.1.2 -Tx Diversity Indicator FALSE -Cell selection and re-selection info Not Present -Cell for measurement Not Present -Inter-frequency measurement quantity (10.3.7.18) -CHOICE reporting critera Inter-frequency reporting criteria -Filter coefficient (10.3.7.9) 0 -CHOICE mode FDD -Measurement quantity for frequency quality estimate CPICH_Ec/No -Inter-frequency reporting quantity (10.3.7.21) -UTRA carrier RSSI -Frequency quality estimate -Non frequency related cell reporting quantities (10.3.7.5) -SFN-SFN observed time difference reporting indicator No report -Cell synchronisation information reporting indicator FALSE -Cell identity reporting indicator FALSE -CHOICE mode FDD -CPICH Ec/N0 reporting indicator TRUE -CPICH RSCP reporting indicator FALSE -Pathloss reporting indicator FALSE -Reporting cell status (10.3.7.61) Not Present -Measurement validity (10.3.7.51) Not Present -CHOICE report criteria Inter-frequency measurement reporting criteria -Inter-frequency measurement reporting criteria (10.3.7.19) -Parameters required for each event 1 -Intra-frequency event identity Event 2C -Threshold used frequency Not Present -W Used frequency Not Present -Hysteresis 0 dB -Time to trigger 0 ms -Reporting Cell Status (10.3..61) -CHOICE reported cell Report cells within active and/or monitored set on used frequency or within virtual active and/or monitored set on non-used frequency -Maximum number of reported cells 3 -Parameters required for each non-used frequenc - Threshold non-used frequency -18 - W non-used frequency 1 Physical channel information elements -DPCH compressed mode status info (10.3.6.34) Not Present MEASUREMENT REPORT message (step 6) Information Element Value/remark Message Type (10.2.17) Integrity check info Not Present Measurement identity 1 Measured Results (10.3.7.44) -CHOICE Measurement Inter-frequency Measured results list -Inter-frequency measured results 1 -Frequency info -CHOICE mode FDD -UARFCN uplink (Nu) Not Present -UARFCN downlink (Nd) Same frequency as channel 2 -UTRA carrier RSSI Not Present -Inter-frequency cell measured results 1 -Cell measured results (10.3.7.3) -Cell identity Not Present -SFN-SFN observed time difference Not Present -Cell synchronisation info Not Present -CHOICE mode FDD -Primary CPICH Info -Primary scrambling code Set to Primary scrambling code of Cell2 -CPICH Ec/No Checked that this IE is present -CPICH RSCP Not Present -Pathloss Not Present Measured results on RACH Not Present Additional measured results Not Present Event results (10.3.7.7) -CHOICE event result Inter-frequency measurement event results -Inter-frequency event identity 2C -Inter-frequency cells 1 -Frequency Info -CHOICE mode FDD -UARFCN uplink (Nu) Not Present -UARFCN downlink (Nd) Same frequency as channel 2 -CHOICE mode FDD -Primary CPICH info -Primary Scrambling Code Set to Primary scrambling code of Cell2
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.3.1.4.2 1,28 Mcps TDD Option
Cell 1 is current active TDD cell, Cell 2 is a FDD cell. The power level of CPICH RSCP of cell 2 and the P-CCPCH RSCP of cell 1 is changed. General test parameters are given in the table 8.6.3.1.3 below and they are signalled from test device. New measurement control information, which defines neighbour cells etc., is always sent before the handover starts. The test parameters are given in Table 8.6.3.1.4 below. Table 8.6.3.1.3: General test parameters for Correct reporting of FDD neighbours in AWGN propagation condition 1,28Mcps option Parameter Unit Value Comment DPCH parameters active cell DL Reference Measurement Channel 12.2 kbps As specified in TS 25.102 section A. The DPCH is located in an other timeslot than 0. Power Control On Target quality value on DTCH BLER 0.01 Active cell Initial conditions Active cell Cell 1 1.28Mcps TDD cell Neighbour cell Cell2 FDD cell Final conditions Active cell Cell 1 1.28Mcps TDD cell Threshold non used frequency dBm -86 Absolute CPICH RSCP threshold for event 2C Hysteresis dB 0 W non-used frequency 1 Applicable for event 2C Time to Trigger ms 0 Filter coefficient 0 Monitored cell list size 6 TDD neighbours on Channel 1 6 FDD neighbours on Channel 2 Measurement control information is sent before T1 starts. T1 s 10 T2 s 10 Table 8.6.3.1.4 Cell Specific parameters for Correct reporting of FDD neighbours in AWGN propagation condition: 1,28Mcps option Parameter Unit Cell 1 Cell 2 Timeslot Number 0 DwPTS n.a n.a. T1 T2 T1 T2 T1 T2 UTRA RF Channel Number Channel 1 Channel 2 CPICH_Ec/Ior dB n.a. n.a. -10 -10 PCCPCH_Ec/Ior dB -3 -3 -12 -12 SCH_Ec/Ior dB n.a. n.a. n.a. n.a. -12 -12 PICH_Ec/Ior dB n.a. n.a. n.a. n.a. -15 -15 DwPCH_Ec/Ior dB 0 0 n.a. n.a. OCNS dB -3 -3 -0,941 -0,941 dB 3 3 3 3 -Infinity -2 dBm/1.28MHz -70 dBm/3.84 MHz -70 CPICH_RSCP dBm n.a. -Infinity -82 PCCPCH_RSCP dBm -70 -70 n.a. n.a. Propagation Condition AWGN AWGN Note: The DPCH of cell 1 is located in a timeslot other than 0.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.3.1.4.2.1 Test Procedure
1) The RF parameters are set up according to T1. 2) The UE is switched on. 3) A call is set up according to the generic set-up procedure specified in TS 34.108 [3] subclause 7.4.2 to place the UE in CELL_DCH. 4) SS shall transmit a MEASUREMENT CONTROL message. 5) After 15 seconds from the beginning of T1, the SS shall switch the power settings from T1 to T2. 6) UE shall transmit a MEASUREMENT REPORT message triggered by event 2C for cell 2. The measurement reporting delay from the beginning of T2 shall be less than 5040 ms. If the UE fails to report the event within the required delay, then a failure is recorded. If the reporting delay for this event is within the required limit, the number of succesfull tests is increased by one. 7) After 10 seconds from the beginning of T2, the UE is switched off. Any timing information of cell 2 is deleted in the UE. 8) Repeat steps 1-7 [TBD] times. Specific Message Contents All messages indicated above shall use the same content as described in the default message content in clause 9 of 34.108 [3] and in Annex A of 34.123-1 [21], with the following exceptions: Note: 10.x.y.z in the IE description refers to clauses in TS 25.331 [9]. MEASUREMENT CONTROL message (step 4): Information Element/Group name Value/Remark Message Type (10.2.17) UE information elements -RRC transaction identifier 0 -Integrity check info Not Present Measurement Information elements -Measurement Identity 1 -Measurement Command (10.3.7.46) Modify -Measurement Reporting Mode (10.3.7.49) -Measurement Report Transfer Mode AM RLC -Periodical Reporting / Event Trigger Reporting Mode Event trigger -Additional measurements list (10.3.7.1) Not Present -CHOICE Measurement type Inter-frequency measurement -Inter-frequency measurement (10.3.7.16) -Inter-frequency measurement objects list (10.3.7.13) -CHOICE inter-frequency cell removal No inter-frequency cells removed -New inter-frequency cells 1 -Inter-frequency cell id 1 -Frequency info (10.3.6.36) -CHOICE mode FDD -UARFCN uplink (Nu) Not Present -UARFCN downlink (Nd) Same frequency as channel 2 -Cell info (10.3.7.2) -Cell individual offset Not Present -Reference time difference to cell Not Present -Read SFN indicator False -CHOICE mode FDD -Primary CPICH info -Primary scrambling code Set to Primary scrambling code of Cell2 -Primary CPICH Tx Power Set to Primary CPICH Tx Power of Cell2 described in Table 8.6.3.1.2 -Tx Diversity Indicator FALSE -Cell selection and re-selection info Not Present -Cell for measurement Not Present -Inter-frequency measurement quantity (10.3.7.18) -CHOICE reporting critera Inter-frequency reporting criteria -Filter coefficient (10.3.7.9) 0 -CHOICE mode FDD -Measurement quantity for frequency quality estimate CPICH_RSCP -Inter-frequency reporting quantity (10.3.7.21) -UTRA carrier RSSI -Frequency quality estimate -Non frequency related cell reporting quantities (10.3.7.5) -SFN-SFN observed time difference reporting indicator No report -Cell synchronisation information reporting indicator FALSE -Cell identity reporting indicator FALSE -CHOICE mode FDD -CPICH Ec/N0 reporting indicator TRUE -CPICH RSCP reporting indicator FALSE -Pathloss reporting indicator FALSE -Reporting cell status (10.3.7.61) Not Present -Measurement validity (10.3.7.51) Not Present -CHOICE report criteria Inter-frequency measurement reporting criteria -Inter-frequency measurement reporting criteria (10.3.7.19) -Parameters required for each event 1 -Intra-frequency event identity Event 2C -Threshold used frequency Not Present -W Used frequency Not Present -Hysteresis 0 dB -Time to trigger 0 ms -Reporting Cell Status (10.3..61) -CHOICE reported cell Report cells within active and/or monitored set on used frequency or within virtual active and/or monitored set on non-used frequency -Maximum number of reported cells 3 -Parameters required for each non-used frequenc - Threshold non-used frequency -86 - W non-used frequency 1 Physical channel information elements -DPCH compressed mode status info (10.3.6.34) Not Present MEASUREMENT REPORT message (step 6) Information Element Value/remark Message Type (10.2.17) Integrity check info Not Present Measurement identity 1 Measured Results (10.3.7.44) -CHOICE Measurement Inter-frequency Measured results list -Inter-frequency measured results 1 -Frequency info -CHOICE mode FDD -UARFCN uplink (Nu) Not Present -UARFCN downlink (Nd) Same frequency as channel 2 -UTRA carrier RSSI Not Present -Inter-frequency cell measured results 1 -Cell measured results (10.3.7.3) -Cell identity Not Present -SFN-SFN observed time difference Not Present -Cell synchronisation info Not Present -CHOICE mode FDD -Primary CPICH Info -Primary scrambling code Set to Primary scrambling code of Cell2 -CPICH Ec/No Checked that this IE is present -CPICH RSCP Not Present -Pathloss Not Present Measured results on RACH Not Present Additional measured results Not Present Event results (10.3.7.7) -CHOICE event result Inter-frequency measurement event results -Inter-frequency event identity 2C -Inter-frequency cells 1 -Frequency Info -CHOICE mode FDD -UARFCN uplink (Nu) Not Present -UARFCN downlink (Nd) Same frequency as channel 2 -CHOICE mode FDD -Primary CPICH info -Primary Scrambling Code Set to Primary scrambling code of Cell2
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.3.1.4.3 7,68 Mcps TDD Option
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.3.1.4.3.1 Initial conditions
Test environment: normal; see clauses G.2.1 and G.2.2. Frequencies to be tested: mid range; see clause G.2.4. The test parameters are given in Table 8.6.3.1.4.3.1.1 and 8.6.3.1.4.3.1.2. The test consists of two successive time periods, with time durations of T1 and T2 respectively. Two cells shall be present in the test, cell 1 being the serving UTRA TDD cell and cell 2 being a UTRA FDD neighbour cells on the unused frequency. In the measurement control information it is indicated to the UE that event-triggered reporting with Event 2C shall be used and that CPICH Ec/I0 of the best cell on the unused frequency shall be reported together with Event 2C. The Measurement control message shall be sent to the UE such that the delay between the end of the last received TTI containing the message and the beginning of T1 is at least equal to the RRC procedure delay as defined in [9]. The second Beacon timeslot shall be provided in timeslot 8 for cell 1. The DL DPCH shall be transmitted in timeslot 1 and the UL DPCH shall be transmitted in timeslot 3. The TTI of the uplink DCCH shall be 20 ms. Table 8.6.3.1.4.3.1.1: General test parameters for Correct reporting of FDD inter-frequency neighbours in AWGN propagation condition (7,68 Mcps option) Parameter Unit Value Comment DPCH parameters DL Reference Measurement Channel 12.2 kbps As specified in TS 25.102 section A.2.2 Power Control On Target quality value on DTCH BLER 0.01 Initial conditions Active cell Cell 1 UTRA TDD cell Neighbour cell Cell 2 UTRA FDD cell Final conditions Active cell Cell 1 Threshold non used frequency dB -18 Applicable for event 2C W non-used frequency 1 Applicable for event 2C Hysteresis dB 0 Applicable for event 2C Time to Trigger ms 0 Filter coefficient 0 Monitored cell list size 6 TDD neighbours on channel 1 6 FDD neighbours on channel 2 T1 s 15 T2 s 10 Table 8.6.3.1.4.3.1.2: Cell specific parameters for Correct reporting of FDD inter-frequency neighbours in AWGN propagation condition (7,68 Mcps option) Parameter Unit Cell 1 Cell 2 Timeslot Number 0 8 n.a T1 T2 T1 T2 T1 T2 UTRA RF Channel Number Channel 1 Channel 2 CPICH_Ec/Ior dB n.a. n.a. -10 PCCPCH_Ec/Ior dB -3 -3 -12 SCH_Ec/Ior dB -9 -9 -9 -9 -12 SCH_toffset 0 0 0 0 n.a. PICH_Ec/Ior -3 -3 -15 OCNS dB -4,28 -4,28 -4,28 -4,28 -0,941 dB 3 3 3 3 -infinity -1.8 dBm/ 7.68 MHz -70 -70 CPICH_Ec/Io n.a. -infinity -14 PCCPCH_RSCP dB -70 -70 -70 -70 n.a. Propagation Condition AWGN AWGN
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.3.1.4.3.2 Procedure
1) The RF parameters are set up according to T1. 2) The UE is switched on. 3) A call is set up according to the generic set-up procedure specified in TS 34.108 [3] subclause 7.4.2 to place the UE in CELL_DCH. 4) SS shall transmit a MEASUREMENT CONTROL message. 5) After 15 seconds from the beginning of T1, the SS shall switch the power settings from T1 to T2. 6) UE shall transmit a MEASUREMENT REPORT message triggered by event 2C for cell 2. The measurement reporting delay from the beginning of T2 shall be less than 5040 ms. If the UE fails to report the event within the required delay, then a failure is recorded. If the reporting delay for this event is within the required limit, the number of succesfull tests is increased by one. 7) After 10 seconds from the beginning of T2, the UE is switched off. Any timing information of cell 2 is deleted in the UE. 8) Repeat steps 1-7 until the confidence level according to annex F.6.2 is achieved.. Specific Message Contents All messages indicated above shall use the same content as described in the default message content in clause 9 of 34.108 [3] with the following exceptions: Note: 10.x.y.z in the IE description refers to clauses in TS 25.331 [9]. MEASUREMENT CONTROL message (step 4): Information Element/Group name Value/Remark Message Type (10.2.17) UE information elements -RRC transaction identifier 0 -Integrity check info Not Present Measurement Information elements -Measurement Identity 1 -Measurement Command (10.3.7.46) Modify -Measurement Reporting Mode (10.3.7.49) -Measurement Report Transfer Mode AM RLC -Periodical Reporting / Event Trigger Reporting Mode Event trigger -Additional measurements list (10.3.7.1) Not Present -CHOICE Measurement type Inter-frequency measurement -Inter-frequency measurement (10.3.7.16) -Inter-frequency measurement objects list (10.3.7.13) -CHOICE inter-frequency cell removal No inter-frequency cells removed -New inter-frequency cells 1 -Inter-frequency cell id 1 -Frequency info (10.3.6.36) -CHOICE mode FDD -UARFCN uplink (Nu) Not Present -UARFCN downlink (Nd) Same frequency as channel 2 -Cell info (10.3.7.2) -Cell individual offset Not Present -Reference time difference to cell Not Present -Read SFN indicator False -CHOICE mode FDD -Primary CPICH info -Primary scrambling code Set to Primary scrambling code of Cell2 -Primary CPICH Tx Power Set to Primary CPICH Tx Power of Cell2 described in Table 8.6.3.1.2 -Tx Diversity Indicator FALSE -Cell selection and re-selection info Not Present -Cell for measurement Not Present -Inter-frequency measurement quantity (10.3.7.18) -CHOICE reporting critera Inter-frequency reporting criteria -Filter coefficient (10.3.7.9) 0 -CHOICE mode FDD -Measurement quantity for frequency quality estimate CPICH_Ec/No -Inter-frequency reporting quantity (10.3.7.21) -UTRA carrier RSSI -Frequency quality estimate -Non frequency related cell reporting quantities (10.3.7.5) -SFN-SFN observed time difference reporting indicator No report -Cell synchronisation information reporting indicator FALSE -Cell identity reporting indicator FALSE -CHOICE mode FDD -CPICH Ec/N0 reporting indicator TRUE -CPICH RSCP reporting indicator FALSE -Pathloss reporting indicator FALSE -Reporting cell status (10.3.7.61) Not Present -Measurement validity (10.3.7.51) Not Present -CHOICE report criteria Inter-frequency measurement reporting criteria -Inter-frequency measurement reporting criteria (10.3.7.19) -Parameters required for each event 1 -Intra-frequency event identity Event 2C -Threshold used frequency Not Present -W Used frequency Not Present -Hysteresis 0 dB -Time to trigger 0 ms -Reporting Cell Status (10.3..61) -CHOICE reported cell Report cells within active and/or monitored set on used frequency or within virtual active and/or monitored set on non-used frequency -Maximum number of reported cells 3 -Parameters required for each non-used frequenc - Threshold non-used frequency -18 - W non-used frequency 1 Physical channel information elements -DPCH compressed mode status info (10.3.6.34) Not Present MEASUREMENT REPORT message (step 6) Information Element Value/remark Message Type (10.2.17) Integrity check info Not Present Measurement identity 1 Measured Results (10.3.7.44) -CHOICE Measurement Inter-frequency Measured results list -Inter-frequency measured results 1 -Frequency info -CHOICE mode FDD -UARFCN uplink (Nu) Not Present -UARFCN downlink (Nd) Same frequency as channel 2 -UTRA carrier RSSI Not Present -Inter-frequency cell measured results 1 -Cell measured results (10.3.7.3) -Cell identity Not Present -SFN-SFN observed time difference Not Present -Cell synchronisation info Not Present -CHOICE mode FDD -Primary CPICH Info -Primary scrambling code Set to Primary scrambling code of Cell2 -CPICH Ec/No Checked that this IE is present -CPICH RSCP Not Present -Pathloss Not Present Measured results on RACH Not Present Additional measured results Not Present Event results (10.3.7.7) -CHOICE event result Inter-frequency measurement event results -Inter-frequency event identity 2C -Inter-frequency cells 1 -Frequency Info -CHOICE mode FDD -UARFCN uplink (Nu) Not Present -UARFCN downlink (Nd) Same frequency as channel 2 -CHOICE mode FDD -Primary CPICH info -Primary Scrambling Code Set to Primary scrambling code of Cell2
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.3.1.5 Test requirements
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.3.1.5.1 3,84 Mcps TDD Option
The UE shall send one Event 2C triggered measurement report for Cell 2 with a measurement reporting delay less than 5040ms from the beginning of time period T2. The UE shall not send event triggered measurement reports, as long as the reporting criteria are not fulfilled. For the test to pass, the total number of successful tests shall be more than 90% with a confidence level of [FFS]% of the cases.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.3.1.5.2 1,28 Mcps TDD Option
The UE shall send one Event 2C triggered measurement report, with a measurement reporting delay less than 5080ms from the beginning of time period T2. The UE shall not send any measurement reports, as long as the reporting criteria are not fulfilled. The rate of correct events observed during repeated tests shall be at least 90%.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.3.1.5.3 7,68 Mcps TDD Option
The UE shall send one Event 2C triggered measurement report for Cell 2 with a measurement reporting delay less than 5040ms from the beginning of time period T2. The UE shall not send event triggered measurement reports, as long as the reporting criteria are not fulfilled. For the test to pass, the total number of successful tests shall be more than 90% with a confidence level of 95% of the cases.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.4 GSM measurements
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.4.1 Correct reporting of GSM neighbours in AWGN propagation condition
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.4.1.1 3,84 Mcps TDD option
FFS
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.4.1.2 1,28 Mcps TDD option
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.4.1.2.1 Definition and applicability
.In the event triggered reporting period the measurement reporting delay is defined as the time between any event that will trigger a measurement report until the UE starts to transmit over the Uu interface. This requirement assumes that the measurement report is not delayed by other RRC signalling on the DCCH. This measurement reporting delay excludes a delay uncertaint\y resulted when inserting the measurement report to the TTI of the uplink DCCH. The delay uncertainty is twice the TTI of the uplink DCCH. The purpose of this test is to verify that the UE makes correct reporting of an event when doing inter frequency measurements on a neighbouring GSM cell. The test will partly verify the requirements in section 8.4 of [2]. The requirements and this test apply to the combined GSM and TDD (1,28Mcps option) UE.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.4.1.2.2 Minimum requirement
The purpose of this test is to verify that the UE makes correct reporting of an event when doing inter-RAT GSM measurements.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.4.1.2.3 Test purpose
To verify that the UE meets the minimum time requirements for identifying neighbouring GSM cells.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.4.1.2.4 Method of test
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.4.1.2.4.1 Initial condition of Test 1
Test 1 is with BSIC verification required case. Two cells shall be present in the test, Cell 1 is current active TDD cell, cell 2 is a GSM cell. The test consists of three successive time periods, with a time duration of T1, T2 and T3 respectively. The test parameters are given in Tables 8.6.4.1.2.1 and 8.6.4.1.2.2 below. In the measurement control information it is indicated to the UE that event-triggered reporting with Event 3B and 3C shall be used. At the start of time duration T1, the UE may not have any timing information of cell 2. The power level of cell 2 is increased and then reduced, and a measurement report should be triggered at each transition. Table 8.6.4.1.2.1 General test parameters for Correct reporting of GSM neighbours in AWGN propagation condition Parameter Unit Value Comment DCH parameters DL Reference Measurement Channel 12.2 kbps As specified in TS 25.102 section A.2.2. The DPCH is located in an other timeslot than 0. Power Control On Target quality value on DTCH BLER 0.01 Active cell Cell 1 Inter-RAT measurement quantity GSM Carrier RSSI BSIC verification required Required Threshold other system dBm -80 Absolute GSM carrier RSSI threshold for event 3B and 3C. Hysteresis dB 0 Time to Trigger ms 0 Filter coefficient 0 Monitored cell list size 12 TDD neighbours on Channel 1 6 GSM neighbours including ARFCN 1 Measurement control information is sent before T1 starts. T Identify abort s 5.0 T Reconfirm abort s 5.0 T1 s 5 T2 s 7 T3 s 5 Table 8.6.4.1.2.2 Cell specific test parameters for Correct reporting of GSM neighbours in AWGN propagation condition (cell 1) LCR TDD Parameter Unit Cell 1 T1, T2, T3 Timeslot Number 0 DwPTS UTRA RF Channel Number Channel 1 PCCPCH_Ec/Ior dB -3 DwPCH_Ec/Ior dB 0 OCNS_Ec/Ior dB -3 dB 3 dBm/1.28 MHz -70 PCCPCH_RSCP dBm -70 Propagation Condition AWGN Note 1: The power of the OCNS channel that is added shall make the total power from the cell to be equal to Ior. Note 2: PCCPCH RSCP levels have been calculated from other parameters for information purposes. They are not settable parameters themselves. Table 8.6.4.1.2.3 Cell specific test parameters for Correct reporting of GSM neighbours in AWGN propagation condition (cell 2) GSM Parameter Unit Cell 2 T1 T2 T3 Absolute RF Channel Number ARFCN 1 RXLEV dBm -infinity -75 -85
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.4.1.2.4.1 Initial condition of Test 2
Test 2 is without BSIC verification required case. Two cells shall be present in the test, Cell 1 is current active TDD cell, cell 2 is a GSM cell. The test consists of three successive time periods, with a time duration of T1, T2 and T3 respectively. The test parameters are given in Tables 8.6.4.1.2.4 and 8.6.4.1.2.5 below. In the measurement control information it is indicated to the UE that event-triggered reporting with Event 3B and 3C shall be used. At the start of time duration T1, the UE may not have any timing information of cell 2. The power level of cell 2 is increased and then reduced, and a measurement report should be triggered at each transition. Table 8.6.4.1.2.4 General test parameters for Correct reporting of GSM neighbours in AWGN propagation condition Parameter Unit Value Comment DCH parameters DL Reference Measurement Channel 12.2 kbps As specified in TS 25.102 section A.2.2. The DPCH is located in an other timeslot than 0. Power Control On Target quality value on DTCH BLER 0.01 Active cell Cell 1 Inter-RAT measurement quantity GSM Carrier RSSI BSIC verification required Required Threshold other system dBm -80 Absolute GSM carrier RSSI threshold for event 3B and 3C. Hysteresis dB 0 Time to Trigger ms 0 Filter coefficient 0 Monitored cell list size 12 TDD neighbours on Channel 1 6 GSM neighbours including ARFCN 1 Measurement control information is sent before T1 starts. T Identify abort s 5.0 T Reconfirm abort s 5.0 T1 s 5 T2 s 2 T3 s 5 Table 8.6.4.1.2.5 Cell specific test parameters for Correct reporting of GSM neighbours in AWGN propagation condition (cell 1) LCR TDD Parameter Unit Cell 1 T1, T2, T3 Timeslot Number 0 DwPTS UTRA RF Channel Number Channel 1 PCCPCH_Ec/Ior dB -3 DwPCH_Ec/Ior dB 0 OCNS_Ec/Ior dB -3 dB 3 dBm/1.28 MHz -70 PCCPCH_RSCP dBm -70 Propagation Condition AWGN Note 1: The power of the OCNS channel that is added shall make the total power from the cell to be equal to Ior. Note 2: PCCPCH RSCP levels have been calculated from other parameters for information purposes. They are not settable parameters themselves. Table 8.6.4.1.2.6 Cell specific test parameters for Correct reporting of GSM neighbours in AWGN propagation condition (cell 2) GSM Parameter Unit Cell 2 T1 T2 T3 Absolute RF Channel Number ARFCN 1 RXLEV dBm -infinity -75 -85
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.4.1.2.5 Test Procedure
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.4.1.2.5.1 Test 1
1) The RF parameters are set up according to test T1.( see Table 8.6.4.1.2.2 and Table 8.6.4.1.2.3) 2) The UE is switched on. 3) A call is set up according to the generic set-up procedure specified in TS 34.108 [3] subclause 7.4.2 to place the UE in CELL_DCH. 4) SS shall transmit the MEASUREMENT CONTROL message. 5) After 5seconds from the beginning of T1, the SS shall switch the GSM level setting from T1 to T2. 6) UE shall transmit a MEASUREMENT REPORT message triggered by event 3C for cell 2. The measurement reporting delay from the beginning of T2 shall be less than 6.04s. If the UE fails to report the event within the required delay, then a failure is recorded. If the reporting delay for this event is within the required limit, the number of successful tests is increased by one. 7) After 7seconds from the beginning of T2, the SS shall switch the GSM level setting from T2 to T3. 8) UE shall transmit a MEASUREMENT REPORT message triggered by event 3B for cell 2. The measurement reporting delay from the beginning of T3 shall be less than 1040ms. If the UE fails to report the event within the required delay, then a failure is recorded. If the reporting delay for this event is within the required limit, the number of successful tests is increased by one. 9) After the SS receivers the measurement report message in step 8 ) or 5 seconds from the beginning of T3, the UE is switched off. Any timing information of cell 2 is deleted in the UE. 11) Repeat steps 1-9according to Annex F.6.2 Table F.6.2.8. Specific Message Contents All messages indicated above shall use the same content as described in the default message content in clause 9 of 34.108 [3] with the following exceptions.: Note: Numbers in brackets after an item e.g “Message Type (10.2.17)” in the IE description are references to clause numbers in TS 25.331 [9] describing that item in more detail. MEASUREMENT CONTROL message (step 4): Information Element/Group name Value/Remark Message Type (10.2.17) UE information elements -RRC transaction identifier 0 -Integrity check info Measurement Information elements -Measurement Identity 2 -Measurement Command (10.3.7.46) Setup -Measurement Reporting Mode (10.3.7.49) -Measurement Report Transfer Mode AM RLC -Periodical Reporting / Event Trigger Reporting Mode Event trigger -Additional measurements list (10.3.7.1) Not Present -CHOICE Measurement type Inter-RAT measurement -Inter-RAT measurement (10.3.7.27) -Inter-RAT measurement objects list (10.3.7.23) Not Present -Inter-RAT measurement quantity (10.3.7.29) -Measurement quantity for UTRAN quality estimate (10.3.7.38) -Filter coefficient 0 -CHOICE mode TDD -Measurement quantity PCcPCH_RSCP -CHOICE system GSM -Measurement quantity GSM Carrier RSSI -Filter coefficient 0 -BSIC verification required Required -Inter-RAT reporting quantity (10.3.7.32) -Reporting cell status (10.3.7.61) Not Present -CHOICE report criteria Inter-RAT measurement reporting criteria -Inter-RAT measurement reporting criteria (10.3.7.30) -Parameters required for each event 2 -Inter-RAT event identity (10.3.7.24 Event 3B -Threshold own system Not Present -W Not Present -Threshold other system -80 dBm -Hysteresis 0 dB -Time to trigger 0 ms -Reporting cell status (10.3.7.61) -CHOICE reported cell Report cells within active set or within virtual active set or of the other RAT -Maximum number of reported cells 2 -Inter-RAT event identity (10.3.7.24) Event 3C -Threshold own system Not Present -W Not Present -Threshold other system -80 dBm -Hysteresis 0 dB -Time to trigger 0 ms -Reporting cell status (10.3.7.61) -CHOICE reported cell Report cells within active set or within virtual active set or of the other RAT -Maximum number of reported cells 2 Physical channel information elements -DPCH compressed mode status info (10.3.6.34) Not Present First MEASUREMENT REPORT message (step 6) Information Element Value/remark Message Type (10.2.17) Integrity check info Not Present Measurement identity 1 Measured Results (10.3.7.44) -CHOICE Measurement Inter-frequency Measured results list -Inter-frequency measured results 1 -Frequency info -CHOICE mode GSM -UARFCN uplink (Nu) Not Present -UARFCN downlink (Nd) Same frequency as channel 2 -UTRA carrier RSSI Not Present Event results (10.3.7.7) -CHOICE event result Inter-frequency measurement event results -Inter-frequency event identity 3C -Inter-frequency cells 1 Second MEASUREMENT REPORT message (step 8) Information Element Value/remark Message Type (10.2.17) Integrity check info Not Present Measurement identity 1 Measured Results (10.3.7.44) -CHOICE Measurement Inter-frequency Measured results list -Inter-frequency measured results 1 -Frequency info -CHOICE mode GSM -UARFCN uplink (Nu) Not Present -UARFCN downlink (Nd) Same frequency as channel 2 -UTRA carrier RSSI Not Present Event results (10.3.7.7) -CHOICE event result Inter-frequency measurement event results -Inter-frequency event identity 3B -Inter-frequency cells 1
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.4.1.2.5.2 Test 2
1) The RF parameters are set up according to test T1.( see Table 8.6.4.1.2.5 and Table 8.6.4.1.2.6) 2) The UE is switched on. 3) A call is set up according to the generic set-up procedure specified in TS 34.108 [3] subclause 7.4.2 to place the UE in CELL_DCH. 4) SS shall transmit the MEASUREMENT CONTROL message. 5) After 5 seconds from the beginning of T1, the SS shall switch the GSM level setting from T1 to T2. 6) UE shall transmit a MEASUREMENT REPORT message triggered by event 3C for cell 2. The measurement reporting delay from the beginning of T2 shall be less than 1040ms. If the UE fails to report the event within the required delay, then a failure is recorded. If the reporting delay for this event is within the required limit, the number of successful tests is increased by one. 7) After 2 seconds from the beginning of T2, the SS shall switch the GSM level setting from T2 to T3. 8) UE shall transmit a MEASUREMENT REPORT message triggered by event 3B for cell 2. The measurement reporting delay from the beginning of T3 shall be less than 1040ms. If the UE fails to report the event within the required delay, then a failure is recorded. If the reporting delay for this event is within the required limit, the number of successful tests is increased by one. 9) After the SS receivers the measurement report message in step 8 ) or 5 seconds from the beginning of T3, the UE is switched off. Any timing information of cell 2 is deleted in the UE. 10) Repeat steps 1-9according to Annex F.6.2 Table F.6.2.8. Specific Message Contents All messages indicated above shall use the same content as described in the default message content in clause 9 of 34.108 [3] with the following exceptions.: Note: Numbers in brackets after an item e.g “Message Type (10.2.17)” in the IE description are references to clause numbers in TS 25.331 [9] describing that item in more detail. MEASUREMENT CONTROL message (step 4): Information Element/Group name Value/Remark Message Type (10.2.17) UE information elements -RRC transaction identifier 0 -Integrity check info Measurement Information elements -Measurement Identity 2 -Measurement Command (10.3.7.46) Setup -Measurement Reporting Mode (10.3.7.49) -Measurement Report Transfer Mode AM RLC -Periodical Reporting / Event Trigger Reporting Mode Event trigger -Additional measurements list (10.3.7.1) Not Present -CHOICE Measurement type Inter-RAT measurement -Inter-RAT measurement (10.3.7.27) -Inter-RAT measurement objects list (10.3.7.23) Not Present -Inter-RAT measurement quantity (10.3.7.29) -Measurement quantity for UTRAN quality estimate (10.3.7.38) -Filter coefficient 0 -CHOICE mode TDD -Measurement quantity PCcPCH_RSCP -CHOICE system GSM -Measurement quantity GSM Carrier RSSI -Filter coefficient 0 -BSIC verification required Not Required -Inter-RAT reporting quantity (10.3.7.32) -Reporting cell status (10.3.7.61) Not Present -CHOICE report criteria Inter-RAT measurement reporting criteria -Inter-RAT measurement reporting criteria (10.3.7.30) -Parameters required for each event 2 -Inter-RAT event identity (10.3.7.24 Event 3B -Threshold own system Not Present -W Not Present -Threshold other system -80 dBm -Hysteresis 0 dB -Time to trigger 0 ms -Reporting cell status (10.3.7.61) -CHOICE reported cell Report cells within active set or within virtual active set or of the other RAT -Maximum number of reported cells 2 -Inter-RAT event identity (10.3.7.24) Event 3C -Threshold own system Not Present -W Not Present -Threshold other system -80 dBm -Hysteresis 0 dB -Time to trigger 0 ms -Reporting cell status (10.3.7.61) -CHOICE reported cell Report cells within active set or within virtual active set or of the other RAT -Maximum number of reported cells 2 Physical channel information elements -DPCH compressed mode status info (10.3.6.34) Not Present First MEASUREMENT REPORT message (step 6) Information Element Value/remark Message Type (10.2.17) Integrity check info Not Present Measurement identity 1 Measured Results (10.3.7.44) -CHOICE Measurement Inter-frequency Measured results list -Inter-frequency measured results 1 -Frequency info -CHOICE mode GSM -UARFCN uplink (Nu) Not Present -UARFCN downlink (Nd) Same frequency as channel 2 -UTRA carrier RSSI Not Present Event results (10.3.7.7) -CHOICE event result Inter-frequency measurement event results -Inter-frequency event identity 3C -Inter-frequency cells 1 Second MEASUREMENT REPORT message (step 8) Information Element Value/remark Message Type (10.2.17) Integrity check info Not Present Measurement identity 1 Measured Results (10.3.7.44) -CHOICE Measurement Inter-frequency Measured results list -Inter-frequency measured results 1 -Frequency info -CHOICE mode GSM -UARFCN uplink (Nu) Not Present -UARFCN downlink (Nd) Same frequency as channel 2 -UTRA carrier RSSI Not Present Event results (10.3.7.7) -CHOICE event result Inter-frequency measurement event results -Inter-frequency event identity 3B -Inter-frequency cells 1
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.4.1.2.6 Test requirements
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.4.1.2.6.1 Test 1
The UE shall send one Event 3C triggered measurement report for cell 2, with a measurement reporting delay less than 6.04s from the beginning of time period T2. The UE shall send one Event 3B triggered measurement report for cell 2, with a measurement reporting delay less than 1040 ms from the beginning of time period T3. The UE shall not send event triggered measurement reports, as long as the reporting criteria are not fulfilled. The rate of events correctly reported during repeated tests shall be at least 90%.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.4.1.2.6.2 Test 2
The UE shall send one Event 3C triggered measurement report for cell 2, with a measurement reporting delay less than 1040ms from the beginning of time period T2. The UE shall send one Event 3B triggered measurement report for cell 2, with a measurement reporting delay less than 1040 ms from the beginning of time period T3. The UE shall not send event triggered measurement reports, as long as the reporting criteria are not fulfilled. The rate of events correctly reported during repeated tests shall be at least 90%.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.4.1.3 7,68 Mcps TDD option
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.4.1.3.1 Definition and applicability
.In the event triggered reporting period the measurement reporting delay is defined as the time between any event that will trigger a measurement report until the UE starts to transmit over the Uu interface. This requirement assumes that the measurement report is not delayed by other RRC signalling on the DCCH. This measurement reporting delay excludes a delay uncertaint\y resulted when inserting the measurement report to the TTI of the uplink DCCH. The delay uncertainty is twice the TTI of the uplink DCCH. The purpose of this test is to verify that the UE makes correct reporting of an event when doing inter frequency measurements on a neighbouring GSM cell. The test will partly verify the requirements in section 8.4 of [2]. The requirements and this test apply to the combined GSM and TDD (7,68Mcps option) UE.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.4.1.3.2 Minimum requirement
The purpose of this test is to verify that the UE makes correct reporting of an event when doing inter-RAT GSM measurements.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.4.1.3.3 Test purpose
To verify that the UE meets the minimum time requirements for identifying neighbouring GSM cells.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.4.1.3.4 Method of test
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.4.1.3.4.1 Initial conditions
Test environment: normal; see clauses G.2.1 and G.2.2. Frequencies to be tested: mid range; see clause G.2.4. Two cells shall be present in the test, Cell 1 is current active TDD cell, cell 2 is a GSM cell. The test consists of three successive time periods, with a time duration of T1, T2 and T3 respectively. The test parameters are given in Tables 8.6.4.1.3.4.1.1, 8.6.4.1.3.4.1.2 and 8.6.4.1.3.4.1.3 below. In the measurement control information it is indicated to the UE that event-triggered reporting with Event 3B and 3C shall be used. At the start of time duration T1, the UE may not have any timing information of cell 2. The power level of cell 2 is increased and then reduced, and a measurement report should be triggered at each transition. Table 8.6.4.1.3.4.1.1: General test parameters for correct reporting of GSM neighbours in AWGN propagation condition Parameter Unit Value Comment DCH parameters DL Reference Measurement Channel 12.2 kbps As specified in TS 25.102 section A.2.2 Power Control On Target quality value on DTCH BLER 0.01 Active cell Cell 1 Inter-RAT measurement quantity GSM carrier RSSI BSIC verification required Required Threshold other system dBm -80 Absolute GSM carrier RSSI threshold for Events 3B and 3C. Hysteresis dB 0 Time to Trigger ms 0 Filter coefficient 0 Monitored cell list size 12 TDD neighbours on Channel 1 6 GSM neighbours including ARFCN 1 Measurement control information is sent before the start of time period T1. Tidentify abort s 5 As specified in section 8.1.2B.5 of [2] Treconfirm abort s 5 As specified in section 8.1.2B.5 of [2] T1 s 10 T2 s 10 T3 s 10 Table 8.6.4.1.3.4.1.2: Cell specific parameters for correct reporting of GSM neighbours in AWGN propagation condition (cell 1) Parameter Unit Cell 1 T1, T2, T3 DL timeslot number 0 1 UTRA RF Channel number Channel 1 PCCPCH_Ec/Ior dB -3 n.a. SCH_Ec/Ior dB -9 n.a. SCH_toffset 0 n.a. OCNS_Ec/Ior dB -3,12 Note 2 DPCH_Ec/Ior dB n.a. Note 1 Îor/Ioc dB 6 6 Io, Note 1 dBm / 7.68 MHz -70 Propagation condition AWGN Note 1: The DPCH level is controlled by the power control loop Note 2: The power of the OCNS channel that is added shall make the total power from the cell to be equal to Ior. Table 8.6.4.1.3.4.1.3: Cell specific parameters for correct reporting of GSM neighbours in AWGN propagation condition (cell 2) Parameter Unit Cell 2 T1 T2 T3 Absolute RF Channel Number ARFCN 1 RXLEV dBm -85 -75 -85
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.4.1.3.4.2 Test Procedure
1) The RF parameters are set up according to test T1.( see Table 8.6.4.1.3.4.1.2 and Table 8.6.4.1.3.4.1.3) 2) The UE is switched on. 3) A call is set up according to the generic set-up procedure specified in TS 34.108 [3] subclause 7.4.2 to place the UE in CELL_DCH. 4) SS shall transmit the MEASUREMENT CONTROL message. 5) After 5seconds from the beginning of T1, the SS shall switch the GSM level setting from T1 to T2. 6) UE shall transmit a MEASUREMENT REPORT message triggered by event 3C for cell 2. The measurement reporting delay from the beginning of T2 shall be less than 1040ms. If the UE fails to report the event within the required delay, then a failure is recorded. If the reporting delay for this event is within the required limit, the number of successful tests is increased by one. 7) After 7seconds from the beginning of T2, the SS shall switch the GSM level setting from T2 to T3. 8) UE shall transmit a MEASUREMENT REPORT message triggered by event 3B for cell 2. The measurement reporting delay from the beginning of T3 shall be less than 1040ms. If the UE fails to report the event within the required delay, then a failure is recorded. If the reporting delay for this event is within the required limit, the number of successful tests is increased by one. 9) After the SS receivers the measurement report message in step 8 ) or 5 seconds from the beginning of T3, the UE is switched off. Any timing information of cell 2 is deleted in the UE. 11) Repeat steps 1-until the confidence level according to annex F.6.2 is achieved. Specific Message Contents All messages indicated above shall use the same content as described in the default message content in clause 9 of 34.108 [3] with the following exceptions.: Note: Numbers in brackets after an item e.g “Message Type (10.2.17)” in the IE description are references to clause numbers in TS 25.331 [9] describing that item in more detail. MEASUREMENT CONTROL message (step 4): Information Element/Group name Value/Remark Message Type (10.2.17) UE information elements -RRC transaction identifier 0 -Integrity check info Measurement Information elements -Measurement Identity 2 -Measurement Command (10.3.7.46) Setup -Measurement Reporting Mode (10.3.7.49) -Measurement Report Transfer Mode AM RLC -Periodical Reporting / Event Trigger Reporting Mode Event trigger -Additional measurements list (10.3.7.1) Not Present -CHOICE Measurement type Inter-RAT measurement -Inter-RAT measurement (10.3.7.27) -Inter-RAT measurement objects list (10.3.7.23) Not Present -Inter-RAT measurement quantity (10.3.7.29) -Measurement quantity for UTRAN quality estimate (10.3.7.38) -Filter coefficient 0 -CHOICE mode TDD -Measurement quantity PCCPCH_RSCP -CHOICE system GSM -Measurement quantity GSM Carrier RSSI -Filter coefficient 0 -BSIC verification required Required -Inter-RAT reporting quantity (10.3.7.32) Not Present -Reporting cell status (10.3.7.61) Not Present -CHOICE report criteria Inter-RAT measurement reporting criteria -Inter-RAT measurement reporting criteria (10.3.7.30) -Parameters required for each event 2 -Inter-RAT event identity (10.3.7.24 Event 3B -Threshold own system Not Present -W Not Present -Threshold other system -80 dBm -Hysteresis 0 dB -Time to trigger 0 ms -Reporting cell status (10.3.7.61) -CHOICE reported cell Report cells within active set or within virtual active set or of the other RAT -Maximum number of reported cells 2 -Inter-RAT event identity (10.3.7.24) Event 3C -Threshold own system Not Present -W Not Present -Threshold other system -80 dBm -Hysteresis 0 dB -Time to trigger 0 ms -Reporting cell status (10.3.7.61) -CHOICE reported cell Report cells within active set or within virtual active set or of the other RAT -Maximum number of reported cells 2 Physical channel information elements -DPCH compressed mode status info (10.3.6.34) Not Present First MEASUREMENT REPORT message (step 6) Information Element Value/remark Message Type (10.2.17) Integrity check info Not Present Measurement identity 1 Measured Results (10.3.7.44) -CHOICE Measurement Inter-frequency Measured results list -Inter-frequency measured results 1 -Frequency info -CHOICE mode GSM -UARFCN uplink (Nu) Not Present -UARFCN downlink (Nd) Same frequency as channel 2 -UTRA carrier RSSI Not Present Event results (10.3.7.7) -CHOICE event result Inter-frequency measurement event results -Inter-frequency event identity 3C -Inter-frequency cells 1 Inter-RAT cell info indication Not present Second MEASUREMENT REPORT message (step 8) Information Element Value/remark Message Type (10.2.17) Integrity check info Not Present Measurement identity 1 Measured Results (10.3.7.44) -CHOICE Measurement Inter-frequency Measured results list -Inter-frequency measured results 1 -Frequency info -CHOICE mode GSM -UARFCN uplink (Nu) Not Present -UARFCN downlink (Nd) Same frequency as channel 2 -UTRA carrier RSSI Not Present Event results (10.3.7.7) -CHOICE event result Inter-frequency measurement event results -Inter-frequency event identity 3B -Inter-frequency cells 1 Inter-RAT cell info indication Not present
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.4.1.3.4.3 Method of test
The UE shall send one Event 3C triggered measurement report for cell 2, with a measurement reporting delay less than 1040 ms from the start of time period T2. The UE shall send one Event 3B triggered measurement report for cell 2, with a measurement reporting delay less than 1040 ms from the start of time period T3. The UE shall not send any Event 3B or 3C triggered measurement reports, as long as the reporting criteria are not fulfilled. The rate of correct events observed during repeated tests shall be at least 90%.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.4.2 Combined UTRA TDD inter-frequency and GSM Cell search under AWGN propagation condition
Editor’s note: This section is incomplete. The following aspects are either missing or not yet determined: • The Test system uncertainties applicable to this test are undefined • The Test tolerances applicable to this test are undefined
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.4.2.2 1.28 Mcps TDD option
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.4.2.2.1 Definition and applicability
In the event triggered reporting period the measurement reporting delay is defined as the time between any event that will trigger a measurement report until the UE starts to transmit over the Uu interface. This requirement assumes that the measurement report is not delayed by other RRC signalling on the DCCH. This measurement reporting delay excludes a delay uncertaint\y resulted when inserting the measurement report to the TTI of the uplink DCCH. The requirements and this test apply to the combined GSM and TDD (1,28Mcps option) UE.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.4.2.2.2 Minimum requirement
This test is to verify that the UE makes correct reporting of an event when doing inter frequency measurements and GSM measurements.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.4.2.2.3 Test Purpose
This test is to verify that the UE makes correct reporting of an event when doing inter frequency measurements and GSM measurements. The test will partly verify the requirements in TS 25.123 section 8.1A.2.3 combined 8.1A.2.6 [2] under AWGN propagation conditions.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.4.2.2.4 Method of test
This test scenario comprised of 2 UTRA TDD cells working on different frequency, and 1 GSM cell. Test parameters are given in Table 8.6.4.2.2.1, 8.6.4.2.2.2, and 8.6.4.2.2.3. Scheduled idle interval of 80ms period as defined in TS25.331 is provided. Two UTRA TDD cells shall be synchronized, i.e. sharing the same frame and timeslot timing. The test consists of 3 successive time periods, with time duration T1, T2 and T3. In the measurement control information it is indicated to the UE that event-triggered reporting with Event 2C and 3C shall be used. Table 8.6.4.2.2.1: General test parameters for combined UTRA TDD inter-frequency and GSM cells search under AWGN propagation conditions Parameter Unit Value Comment DPCH parameters active cell DL Reference Measurement Channel 12.2 kbps As specified in TS 25.102 section A.2.2. Power Control On Target quality value on DTCH BLER 0.01 Active cell Cell 1 1.28Mcps TDD cell operating on channel 1 Neighbour cell Cell 2 1.28Mcps TDD cell operating on channel 2 Cell 3 GSM cell Tnon used 2c dBm -71 Absolute P-CCPCH RSCP threshold for event 2C Inter-RAT measurement quantity GSM carrier RSSI BSIC verification required Required Tother_RAT dBm -80 Absolute GSM carrier RSSI threshold for event 3C H2c dB 0 The hysteresis parameter for the event 2C H3C dB 0 The hysteresis parameter for the event 3C TimeToTrigger ms 0 Filter coefficient 0 L3 filtering is not used Monitored cell list size 16 TDD neighbour on channel 1 6 GSM neighbours including ARFCN 1 Propagation Condition AWGN T1 s 5 During T1, cell 2 and cell 3 shall be powered off. T2 s 6 T3 s 8 Table 8.6.4.2.2.2: Cell specific test parameters for combined UTRA TDD inter-frequency and E-UTRA FDD cell search under fading propagation conditions (cell 1 and cell 2) Parameter Unit Cell 1 (UTRA) Cell 2 (UTRA) Timeslot Number 0 DwPTS 0 DwPTS T1 T2 T3 T1 T2 T3 T1 T2 T3 T1 T2 T3 UTRA RF Channel Number* Channel 1 Channel 2 PCCPCH_Ec/Ior dB -3 -3 DwPCH_Ec/Ior dB 0 0 OCNS_Ec/Ior dB -3 -3 dB 3 3 -Infinity 6 dBm/1.28 MHz -70 -70 PCCPCH RSCP dBm -70 -Infinity -67 Propagation Condition AWGN Table 8.6.4.2.2.3: Cell specific test parameters for combined UTRA TDD inter-frequency and GSM cell search under AWGN propagation conditions (cell 3) Parameter Unit Cell 3 T1 T2 T3 Absolute RF Channel Number ARFCN 1 RXLEV dBm -Infinity -75
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.4.2.2.5 Test Procedure
1) The RF parameters are set up according to test T1.( see Table 8.6.6.1.2.2 and Table 8.6.6.1.2.2). 2) The UE is switched on. 3) A call is set up according to the generic set-up procedure specified in TS 34.108 [3] subclause 7.4.2 to place the UE in CELL_DCH. 4) SS shall transmit the MEASUREMENT CONTROL message(inter frequency). 5) SS shall transmit the MEASUREMENT CONTROL message(event triggered inter RAT). 6) After 5seconds from the beginning of T1, the SS shall switch the power setting of cell 2 from T1 to T2. 7) UE shall transmit a MEASUREMENT REPORT message triggered by event 2C for cell 2. The measurement reporting delay from the beginning of T2 shall be less than 5.08s. If the UE fails to report the event within the required delay, then a failure is recorded. If the reporting delay for this event is within the required limit, the number of successful tests is increased by one. 8) After 6seconds from the beginning of T2, the SS shall switch the GSM level setting from T2 to T3. 9) UE shall transmit a MEASUREMENT REPORT message triggered by event 3C for cell 2. The measurement reporting delay from the beginning of T3 shall be less than 6.04s. If the UE fails to report the event within the required delay, then a failure is recorded. If the reporting delay for this event is within the required limit, the number of successful tests is increased by one. 10) After the SS receivers the measurement report message in step 8 ) or 8 seconds from the beginning of T3, the UE is switched off. Any timing information of cell 2 and cell 3 is deleted in the UE. 11) Repeat steps 1-9 according to Annex F.6.2 Table F.6.2.8. Specific Message Contents All messages indicated above shall use the same content as described in the default message content in clause 9 of 34.108 [3] with the following exceptions: MEASUREMENT CONTROL (Step 4) Information Element/Group name Value/Remark Message Type UE information elements -RRC transaction identifier 0 -Integrity check info Not Present Measurement Information elements -Measurement Identity 1 -Measurement Command Modify -Measurement Reporting Mode -Measurement Report Transfer Mode AM RLC -Periodical Reporting / Event Trigger Reporting Mode Event trigger -Additional measurements list Not Present -CHOICE Measurement type Inter-frequency measurement -Inter-frequency measurement -Inter-frequency measurement objects list -CHOICE inter-frequency cell removal No inter-frequency cells removed -New inter-frequency cells 1 -Inter-frequency cell id 1 -Frequency info -CHOICE mode TDD -UARFCN(Nt) Same frequency as channel 2 -Cell info -Cell individual offset Not Present -Reference time difference to cell Not Present -Read SFN indicator False -CHOICE mode TDD -Primary CCPCH info -CHOICE mode TDD -CHOICE TDD option 1,28 Mcps TDD -cell parameters ID Set to cell parameters ID of cell 2 -SCTD indicator FALSE -Primary CCPCH Tx power Set to Primary CCPCH Tx power of cell 2 as described in Table 8.6.2.1.2 -Timesllot list Not Present -Cell selection and re-selection info Not Present -Cell for measurement Not Present -Inter-frequency measurement quantity -CHOICE reporting critera Inter-frequency reporting criteria -Filter coefficient 0 -CHOICE mode TDD -Measurement quantity for frequency quality estimate Primary CCPCH RSCP -Inter-frequency reporting quantity -UTRA carrier RSSI FALSE -Frequency quality estimate FALSE -Non frequency related cell reporting quantities -SFN-SFN observed time difference reporting indicator No report -Cell synchronisation information reporting indicator FALSE -Cell identity reporting indicator FALSE -CHOICE mode TDD -Timeslot ISCP reporting indicator FALSE -Proposed TGSN Reporting required FALSE -Primary CCPCH RSCP reporting indicator TRUE -Pathloss reporting indicator FALSE -Reporting cell status Not Present -Measurement validity Not Present -CHOICE report criteria Inter-frequency measurement reporting criteria -Inter-frequency measurement reporting criteria -Parameters required for each event 1 -Inter-frequency event identity Event 2C -Parameters required for each non-used frequenc - Threshold non-used frequency -71 - W non-used frequency 1 Physical channel information elements -DPCH compressed mode status info Not Present MEASUREMENT CONTROL (Step 5) Information Element/Group name Value/Remark Message Type UE information elements -RRC transaction identifier 0 -Integrity check info No present Measurement Information elements -Measurement Identity 2 -Measurement Command Setup -Measurement Reporting Mode -Measurement Report Transfer Mode AM RLC -Periodical Reporting / Event Trigger Reporting Mode Event trigger -Additional measurements list Not Present -CHOICE Measurement type Inter-RAT measurement -Inter-RAT measurement -Inter-RAT measurement objects list Not Present -Inter-RAT measurement quantity -Measurement quantity for UTRAN quality estimate -Filter coefficient 0 -CHOICE mode TDD -Measurement quantity PCCPCH RSCP -CHOICE system GSM -Measurement quantity GSM Carrier RSSI -Filter coefficient 0 -BSIC verification required Required -Inter-RAT reporting quantity - UTRAN estimated quality FALSE - CHOICE system GSM - Observed time difference to GSM cell reporting indicator FALSE - GSM Carrier RSSI reporting indicator TRUE -Reporting cell status Not Present -CHOICE report criteria Inter-RAT measurement reporting criteria -Inter-RAT measurement reporting criteria -Inter-RAT event identity Event 3C -Threshold other system -80 -Hysteresis 0 dB -Time to trigger 0 ms -Reporting cell status -CHOICE reported cell Report cells within active set or within virtual active set or of the other RAT -Maximum number of reported cells 2 Physical channel information elements -DPCH compressed mode status info Not present. MEASUREMENT REPORT (Step 7) Information Element Value/remark Message Type Integrity check info Not Present Measurement identity 1 Measured Results -CHOICE Measurement Inter-frequency Measured results list -Inter-frequency measured results 1 -Frequency info -CHOICE mode TDD -UARFCN(Nt) Same frequency as channel 2 -UTRA carrier RSSI Not Present -Inter-frequency cell measured results 1 -Cell measured results -Cell identity Not Present -SFN-SFN observed time difference Not Present -Cell synchronisation info Not Present -CHOICE mode TDD -Cell parameters ID Set to cell parameters ID of Cell 2 -Proposed TGSN Not Present -Primary CCPCH RSCP Checked that this IE is present -Pathloss Not Present -Timeslot list Not Present Measured results on RACH Not Present Additional measured results Not Present Event results -CHOICE event result Inter-frequency measurement event results -Inter-frequency event identity 2C -Inter-frequency cells 1 -Frequency Info -CHOICE mode TDD -UARFCN(Nt) Same frequency as channel 2 -Non frequency related measurement event results -CHOICE mode TDD -Primary CCPCH Info -CHOICE mode TDD -CHOICE TDD Option 1.28 Mcps TDD -TSTD indicator TRUE -Cell Parameters ID Set to cell parameters ID of Cell 2 -SCTD Indicator FALSE MEASUREMENT REPORT(Step 9) Information Element Value/remark Message Type Integrity check info Not Present Measurement identity 2 Event results -CHOICE event result Inter-RAT measurement event results -Inter-frequency event identity 3C - CHOICE BSIC - Non verified BSIC - BCCH ARFCN Same as cell 3
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.4.2.2.6 Test Requirement
The UE shall send one Event 2C triggered measurement report, with a measurement reporting delay less than 5080ms from the beginning of time period T2. The UE shall send one Event 3C triggered measurement report for cell 3, with a measurement reporting delay less than 6040ms from the beginning of time period T3. The UE shall not send event triggered measurement reports, as long as the reporting criteria are not fulfilled. The rate of events correctly reported during repeated tests shall be at least 90%.
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.5 E-UTRA measurements
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.5.1 UTRA TDD to E-UTRA FDD cell search under fading propagation conditions
Editor’s note: This Test case is incomplete for frequencies above 3GHz • The Test system uncertainties applicable above 3GHz are undefined • The Test Tolerances and Test Requirements applicable above 3GHz are undefined
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.5.1.1 Definition and applicability
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.5.1.1.1 3,84 Mcps TDD Option
40bd05ebf1e9d686c3dc55dd3e817398
34.122
8.6.5.1.1.2 1,28 Mcps TDD Option
The purpose of this test is to verify that the UE makes correct reporting of an event when measuring on E-UTRA FDD cells. This test will partly verify the E-UTRA FDD cell search requirements in TS 25.123 [2] section 8.1A.2.6 under fading propagation conditions. The requirements and this test apply to release 9 and later releases UTRA 1.28Mcps TDD UEs that support release 8 and later releases E-UTRA FDD.