ICSA-22-167-14 | Siemens OpenSSL Affected Industrial Products (Update C) | The BN_mod_sqrt() function in openSSL, which computes a modular square root, contains a bug that can cause it to loop forever for non-prime moduli. Internally this function is used when parsing certificates that contain elliptic curve public keys in compressed form or explicit elliptic curve parameters with a base point encoded in compressed form. It is possible to trigger the infinite loop by crafting a certificate that has invalid explicit curve parameters. Since certificate parsing happens prior to verification of the certificate signature, any process that parses an externally supplied certificate may thus be subject to a denial of service attack. The infinite loop can also be reached when parsing crafted private keys as they can contain explicit elliptic curve parameters. (https://www.openssl.org/news/secadv/20220315.txt). CVE-2022-0778 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H). | [] | null | 7.5 | null | null |
ICSA-21-306-01 | Sensormatic Electronics VideoEdge | A vulnerability in the JQuery web user interface (UI) component could allow a webpage to be altered before it is served to users.CVE-2020-11023 has been assigned to this vulnerability. A CVSS v3 base score of 6.1 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N). | [] | null | null | 6.1 | null |
ICSA-22-258-03 | Siemens RUGGEDCOM ROS | Affected devices improperly handle partial HTTP requests which makes them vulnerable to slowloris attacks.
This could allow a remote attacker to create a denial of service condition that persists until the attack ends. CVE-2022-39158 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L). | [] | null | 5.3 | null | null |
ICSA-24-228-05 | Siemens LOGO! V8.3 BM Devices | Affected devices store user passwords in plaintext without proper protection. This could allow a physical attacker to retrieve them from the embedded storage ICs. | [] | null | 4.6 | null | null |
ICSA-21-343-02 | WECON LeviStudioU | The affected product is vulnerable to multiple stack-based buffer overflow instances while parsing project files, which may allow an attacker to execute arbitrary code.CVE-2021-43983 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been assigned; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). | [] | null | null | 7.8 | null |
ICSA-17-353-04 | Siemens LOGO! Soft Comfort | The update center of LOGO! Soft Comfort lacks integrity verification on software packages downloaded via an unprotected communication channel. This could allow a remote attacker to manipulate the software package while performing a man-in-the-middle (MitM) attack.CVE-2017-12740 has been assigned to this vulnerability. A CVSS v3 base score of 5.9 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N). | [] | null | null | 5.9 | null |
ICSA-19-225-03 | ICSA-19-225-03_Siemens SCALANCE X Switches (Update D) | An attacker may send large message packages repeatedly to the telnet service, which may allow a denial-of-service condition.CVE-2019-10942 has been assigned to this vulnerability. A CVSS v3 base score of 8.6 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H). | [] | null | null | 8.6 | null |
ICSA-22-090-06 | General Electric Renewable Energy MDS Radios | This previously disclosed vulnerability in the GoAhead Webserver may allow remote code execution in iNET/iNET II, TD220X, and TD220MAX series radios.CVE-2017-17562 has been assigned to this vulnerability. A CVSS v3 base score of 10.0 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H). iNET/iNET II series radios allow unauthenticated local and network access to the device configuration shell.CVE-2022-24119 has been assigned to this vulnerability. A CVSS v3 base score of 10.0 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H). This vulnerability identifies a weakness in the wireless security software and chipset implementations in iNET/iNET II series radios.CVE-2022-24116 has been assigned to this vulnerability. A CVSS v3 base score of 8.0 has been calculated; the CVSS vector string is (AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). A feature can allow the use of an authentication code to cause iNET/iNET II, SD, TD220X, and TD220MAX series radios to reset back to the factory default configuration and reboot.CVE-2022-24118 has been assigned to this vulnerability. A CVSS v3 base score of 6.8 has been calculated; the CVSS vector string is (AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:H). iNET and iNET II series radios store credentials in plaintext on the system flash memory.CVE-2022-24120 has been assigned to this vulnerability. A CVSS v3 base score of 6.8 has been calculated; the CVSS vector string is (AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). There is no cryptographic signature to verify authenticity of firmware.CVE-2022-24117 has been assigned to this vulnerability. A CVSS v3 base score of 8.4 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:H/UI:R/S:C/C:H/I:H/A:H). | [] | null | null | 8.4 | null |
ICSA-20-140-02 | Emerson OpenEnterprise | The affected components may allow an attacker to run an arbitrary commands with system privileges or perform remote code execution via a specific communication service.CVE-2020-10640 has been assigned to this vulnerability. A CVSS v3 base score of 10.0 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H). Inadequate folder security permissions may allow modification of important configuration files, which could cause the system to fail or behave in an unpredictable manner.CVE-2020-10632 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H). Inadequate encryption may allow the passwords for OpenEnterprise user accounts to be obtained.CVE-2020-10636 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:N/A:N). | [] | null | null | 6.5 | null |
ICSA-22-195-16 | Siemens EN100 Ethernet Module | Affected applications contains a memory corruption vulnerability while parsing specially crafted HTTP packets to /txtrace endpoint manupulating a specific argument. This could allow an attacker to crash the affected application leading to a denial of service condition | [] | null | 8.6 | null | null |
ICSA-22-242-08 | Honeywell Trend Controls Inter-Controller Protocol | Several Trend Controls IQ Series building automation controllers utilize an Inter-Controller (IC) protocol that uses a 4-digit authentication PIN transmitted in plaintext, allowing usernames and passwords to be transmitted in plaintext when utilizing unsupported legacy versions of the controller. This may allow an attacker with local OT network access to obtain these credentials.CVE-2022-30312 has been assigned to this vulnerability. A CVSS v3 base score of 7.1 has been assigned; the CVSS vector string is (AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:N). | [] | null | null | 7.1 | null |
ICSA-19-290-02 | Horner Automation Cscape | An improper input validation vulnerability has been identified that may be exploited by processing files lacking user input validation. This may allow an attacker to access information and remotely execute arbitrary code.CVE-2019-13541 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). Improper validation of data may cause the system to write outside the intended buffer area, which may allow arbitrary code execution.CVE-2019-13545 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). | [] | null | null | 7.8 | null |
ICSA-23-094-01 | Nexx Smart Home Device | The listed versions of Nexx Smart Home devices use hard-coded credentials. An attacker with unauthenticated access to the Nexx Home mobile application or the affected firmware could view the credentials and access the MQ Telemetry Server (MQTT) server and the ability to remotely control garage doors or smart plugs for any customer. CVE-2023-1748 has been assigned to this vulnerability. A CVSS v3 base score of 9.3 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:L). The listed versions of Nexx Smart Home devices lack proper access control when executing actions. An attacker with a valid NexxHome deviceId could send API requests that the affected devices would execute. CVE-2023-1749 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N). The listed versions of Nexx Smart Home devices lack proper access control when executing actions. An attacker with a valid NexxHome deviceId could retrieve device history, set device settings, and retrieve device information. CVE-2023-1750 has been assigned to this vulnerability. A CVSS v3 base score of 7.1 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:N). The listed versions of Nexx Smart Home devices use a WebSocket server that does not validate if the bearer token in the Authorization header belongs to the device attempting to associate. This could allow any authorized user to receive alarm information and signals meant for other devices which leak a deviceId. CVE-2023-1751 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N). The listed versions of Nexx Smart Home devices could allow any user to register an already registered alarm or associated device with only the device’s MAC address. CVE-2023-1752 has been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:H). | [] | null | null | 8.1 | null |
ICSA-21-210-02 | Wibu-Systems CodeMeter Runtime | A buffer over-read vulnerability in the CodeMeter Runtime network server could cause the server to return packets containing data from the heap.
An unauthenticated remote attacker could exploit this issue to disclose heap memory contents or crash the CodeMeter Runtime Server (i.e., CodeMeter.exe). A buffer over-read vulnerability in the HTTP(S) service of the CodeMeter Runtime CmWAN server could cause the server to crash.
An unauthenticated remote attacker with access to the CmWAN port could exploit this issue to crash the CodeMeter Runtime Server (i.e., CodeMeter.exe). | [] | null | 7.5 | null | null |
ICSA-19-078-01 | AVEVA InduSoft Web Studio and InTouch Edge HMI | The uncontrolled search path element vulnerability allows an attacker to load and execute a malicious file from the ux32w.dll in third-party component Sentinel UltraPro.CVE-2019-6534 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H). | [] | null | null | 6.5 | null |
ICSA-23-157-01 | Delta Electronics CNCSoft-B DOPSoft | Delta Electronics' DOPSoft versions prior to v4.0.0.82, a component of CNCSoft-B 1.0.0.4, are vulnerable to stack-based buffer overflow, which could allow an attacker to execute arbitrary code. Delta Electronics' DOPSoft versions prior to v4.0.0.82, a component of CNCSoft-B 1.0.0.4, are vulnerable to heap-based buffer overflow, which could allow an attacker to execute arbitrary code. Delta Electronics' CNCSoft-B version 1.0.0.4 DOPSoft versions 4.0.0.82 and prior are vulnerable to stack-based buffer overflow, which could allow an attacker to execute arbitrary code. | [] | null | null | 7.8 | null |
ICSA-19-136-01 | Schneider Electric Modicon Controllers | The device has predictable TCP initial sequence numbers that allow attackers to hijack TCP connections carrying unsecured communications.CVE-2019-6821has been assigned to this vulnerability. A CVSS v3 base score of 5.4 has been calculated; the CVSS vector string is (AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N). | [] | null | null | 5.4 | null |
ICSA-20-105-09 | Siemens TIM 3V-IE and 4R-IE Family Devices | The affected versions contain an open debug port that is available under certain specific conditions. The vulnerability is only available if the IP address is configured to 192.168.1.2. If available, the debug port could be exploited by an attacker with network access to the device. No user interaction is required to exploit this vulnerability. The vulnerability impacts confidentiality, integrity, and availability of the affected device. At the stage of publishing this security advisory no public exploitation is known. | [] | null | 9 | null | null |
ICSA-24-228-03 | Siemens Teamcenter Visualization and JT2Go | The affected applications contain an out of bounds read past the unmapped memory region while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. The affected applications contain a null pointer dereference vulnerability while parsing specially crafted X_T files. An attacker could leverage this vulnerability to crash the application causing denial of service condition. | [] | null | 3.3 | null | null |
ICSA-19-085-01 | Siemens SCALANCE X (Update D) | The monitor barrier of the affected products insufficiently blocks data from being forwarded over the mirror port and into the mirrored network. An attacker could exploit this vulnerability to transmit malicious packets to systems in the mirrored network to influence their configuration and runtime behavior.
This vulnerability could be exploited by an attacker with network access to the traffic-receiving network. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise the confidentiality and availability of the traffic-generating network.
CVE-2019-6569 has been assigned to this vulnerability. A CVSS v3 base score of 5.4 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:C/C:L/I:N/A:L). | [] | null | 5.4 | null | null |
ICSA-18-352-02 | Advantech WebAccess/SCADA | Lack of proper validation of user supplied input may allow an attacker to cause the overflow of a buffer on the stack.CVE-2018-18999 has been assigned to this vulnerability. A CVSS v3 base score of 7.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L). | [] | null | null | 7.3 | null |
ICSA-21-040-10 | Siemens DIGSI 4 | Several folders in the %PATH% are writeable by normal users. As these folders are included in the search for dlls, an attacker could place dlls there with code executed by SYSTEM. | [] | null | 7.8 | null | null |
ICSA-19-010-02 | Omron CX-One CX-Protocol | Three type confusion vulnerabilities exist when processing project files. An attacker could use a specially crafted project file to exploit and execute code under the privileges of the application.CVE-2018-19027 has been assigned to this vulnerability. A CVSS v3 base score of 6.6 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:H). | [] | null | null | 6.6 | null |
ICSA-21-341-01 | Hitachi Energy RTU500 OpenLDAP | A vulnerability exists in the affected OpenLDAP versions leading to an LDAP service crash in the parsing of a keystring, resulting in a denial-of-service condition.CVE-2020-36229 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H). A vulnerability exists in the affected OpenLDAP versions leading in an assertion failure in an LDAP service in the parsing of a file, resulting in a denial-of-service condition.CVE-2020-36230 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H). | [] | null | null | 7.5 | null |
ICSA-23-257-04 | Siemens RUGGEDCOM APE1808 Products | An attacker with local access to the system could potentially disclose information
from protected memory areas via a side-channel attack on the processor cache. Existing CommBuffer checks in SmmEntryPoint will not catch underflow when computing BufferSize. An issue was discovered in IhisiSmm in Insyde InsydeH2O with kernel 5.0 through 5.5. IHISI function 0x17 verifies that the output buffer lies within the command buffer but does not verify that output data does not go beyond the end of the command buffer. In particular, the GetFlashTable function is called directly on the Command Buffer before the DataSize is check, leading to possible circumstances where the data immediately following the command buffer could be destroyed before returning a buffer size error. Using SPI injection, it is possible to modify the FDM contents after it has been measured. This TOCTOU attack could be used to alter data and code used by the remainder of the boot process. Some versions of InsydeH2O use the FreeType tools to embed fonts into the BIOS. InsydeH2O does not use the FreeType API at runtime and usage during build time does not produce a vulnerability in the BIOS. The CVSS reflects this limited usage. In UsbCoreDxe, untrusted input may allow SMRAM or OS memory tampering Use of untrusted pointers could allow OS or SMRAM memory tampering leading to escalation of privileges. This issue was discovered by Insyde during security review. https://www.insyde.com/security-pledge/SA-2022058 In UsbCoreDxe, tampering with the contents of the USB working buffer using DMA while certain USB transactions are in process leads to a TOCTOU problem that could be used by an attacker to cause SMRAM corruption and escalation of privileges The UsbCoreDxe module creates a working buffer for USB transactions outside of SMRAM. The code which uses can be inside of SMM, making the working buffer untrusted input. The buffer can be corrupted by DMA transfers. The SMM code code attempts to sanitize pointers to ensure all pointers refer to the working buffer, but when a pointer is not found in the list of pointers to sanitize, the current action is not aborted, leading to undefined behavior. This issue was discovered by Insyde engineering based on the general description provided by Intel's iSTARE group. Fixed in: Kernel 5.0: Version 05.09. 21 Kernel 5.1: Version 05.17.21 Kernel 5.2: Version 05.27.21 Kernel 5.3: Version 05.36.21 Kernel 5.4: Version 05.44.21 Kernel 5.5: Version 05.52.21 https://www.insyde.com/security-pledge/SA-2022063 Manipulation of the input address in PnpSmm function 0x52 could be used by malware to overwrite SMRAM or OS kernel memory. Function 0x52 of the PnpSmm driver is passed the address and size of data to write into the SMBIOS table, but manipulation of the address could be used by malware to overwrite SMRAM or OS kernel memory. This issue was discovered by Insyde engineering during a security review. This issue is fixed in: Kernel 5.0: 05.09.41 Kernel 5.1: 05.17.43 Kernel 5.2: 05.27.30 Kernel 5.3: 05.36.30 Kernel 5.4: 05.44.30 Kernel 5.5: 05.52.30 https://www.insyde.com/security-pledge/SA-2022065 DMA attacks on the PnpSmm shared buffer used by SMM and non-SMM code could cause TOCTOU race-condition issues that could lead to corruption of SMRAM and escalation of privileges. DMA attacks on the FwBlockServiceSmm shared buffer used by SMM and non-SMM code could cause TOCTOU race-condition issues that could lead to corruption of SMRAM and escalation of privileges. DMA attacks on the IHISI command buffer could cause TOCTOU issues which could lead to corruption of SMRAM and escalation of privileges. DMA attacks on the VariableRuntimeDxe shared buffer used by SMM and non-SMM code could cause TOCTOU race-condition issues that could lead to corruption of SMRAM and escalation of privileges. DMA attacks on the FvbServicesRuntimeDxe shared buffer used by SMM and non-SMM code could cause TOCTOU race-condition issues that could lead to corruption of SMRAM and escalation of privileges. DMA attacks on the SdHostDriver buffer used by SMM and non-SMM code could cause TOCTOU race-condition issues that could lead to corruption of SMRAM and escalation of privileges. DMA attacks on the SdMmcDevice buffer used by SMM and non-SMM code could cause TOCTOU race-condition issues that could lead to corruption of SMRAM and escalation of privileges. An issue was discovered in Insyde InsydeH2O with kernel 5.0 through 5.5. An SMM memory corruption vulnerability in the FvbServicesRuntimeDxe driver allows an attacker to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM. An issue was discovered in Insyde InsydeH2O with kernel 5.0 through 5.5. The SMI handler for the FwBlockServiceSmm driver uses an untrusted pointer as the location to copy data to an attacker-specified buffer, leading to information disclosure. An issue was discovered in Insyde InsydeH2O with kernel 5.0 through 5.5. The FwBlockSericceSmm driver does not properly validate input parameters for a software SMI routine, leading to memory corruption of arbitrary addresses including SMRAM, and possible arbitrary code execution. An issue SMM memory leak vulnerability in SMM driver (SMRAM was discovered in Insyde InsydeH2O with kernel 5.0 through 5.5. An attacker can dump SMRAM contents via the software SMI provided by the FvbServicesRuntimeDxe driver to read the contents of SMRAM, leading to information disclosure. An issue was discovered in Insyde InsydeH2O with kernel 5.0 through 5.5. An SMM callout vulnerability in the SMM driver FwBlockServiceSmm, creating SMM, leads to arbitrary code execution. An attacker can replace the pointer to the UEFI boot service GetVariable with a pointer to malware, and then generate a software SMI. An attacker who has physical access or Administrative rights to a target device could install an affected boot policy which could bypass Security Boot. An issue was discovered in Insyde InsydeH2O with kernel 5.0 through 5.5. Due to insufficient input validation, an attacker can tamper with a runtime-accessible EFI variable to cause a dynamic BAR setting to overlap SMRAM. An issue was discovered in SysPasswordDxe in Insyde InsydeH2O with kernel 5.0 through 5.5. System password information could optionally be stored in cleartext, which might lead to possible information disclosure. | [] | null | 5.1 | null | null |
ICSA-20-042-08 | Siemens SIPORT MP | Vulnerable versions of the device allow the creation of special accounts ("service users") with administrative privileges that could enable a remote authenticated attacker to perform actions that are not visible to other users of the system, such as granting persons access to a secured area. | [] | null | 6.5 | null | null |
ICSA-21-096-01 | Hitachi Energy Relion 670, 650 and SAM600-IO | An attacker with access to the IEC 61850 network and knowledge of how to reproduce the attack�as well as the IP addresses of the different IEC 61850 access points (of IEDs/products)�can force the device to reboot, which renders the device inoperable for approximately 60 seconds. This vulnerability affects only products with IEC 61850 interfaces. | [] | null | null | 7.5 | null |
ICSMA-21-215-01 | Swisslog Healthcare Translogic PTS | User and root accounts have hardcoded passwords that can be accessed remotely on the Nexus Control Panel. These accounts are enabled by default and cannot be turned off by native configuration of the system.CVE-2021-37163 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). A user logged in using the default credentials can gain root access to the device, which allows permissions for all the functionalities of the device.CVE-2021-37167 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H). A buffer overflow allows an attacker to overwrite an internal queue data structure, which could allow remote code execution.CVE-2021-37161 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). A buffer overflow allows an attacker to overwrite an internal queue data structure, which could allow remote code execution.CVE-2021-37162 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). A specially crafted message to the HMI may cause an overflow, which could allow remote code execution.CVE-2021-37165 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). Received data can be copied to a stack buffer, resulting in an overflow.CVE-2021-37164 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). The method used to bind a local service to ports on device interfaces may allow the connection to be hijacked by an external attacker.CVE-2021-37166 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). There is no file validation during an upload for an update.CVE-2021-37160 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N). | [] | null | null | 7.5 | null |
ICSA-18-023-02 | Siemens Industrial Products (Update A) | Specially crafted PROFINET DCP broadcast packets could cause a Denial-of-Service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected. CVE-2017-2680 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been calculated; the CVSS vector string is (AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H). | [] | null | null | 6.5 | null |
ICSMA-20-163-01 | Philips IntelliBridge Enterprise IBE | Unencrypted user credentials received in the IntelliBridge Enterprise (IBE) are logged within the transaction logs, which are secured behind the login based administrative web portal.
The unencrypted user credentials sent from the affected products listed above, for the purpose of handshake or authentication with the Enterprise Systems, are logged as the payload in IntelliBridge Enterprise (IBE) within the transaction logs. An attacker with administrative privileges could exploit this vulnerability to read plain text credentials from log files.CVE-2020-12023 has been assigned to this vulnerability. A CVSS v3 base score of 2.0 has been calculated; the CVSS vector string is (AV:A/AC:H/PR:H/UI:N/S:U/C:L/I:N/A:N). | [] | null | null | 2 | null |
ICSA-20-168-01 | Treck TCP/IP Stack (Update H) | Improper handling of length parameter inconsistency in IPv4/UDP component when handling a packet sent by an unauthorized network attacker. This vulnerability may result in remote code execution.CVE-2020-11896 has been assigned to this vulnerability. A CVSS v3 base score of 10.0 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H). Improper handling of length parameter inconsistency in IPv6 component when handling a packet sent by an unauthorized network attacker. This vulnerability may result in possible out-of-bounds write.CVE-2020-11897 has been assigned to this vulnerability. A CVSS v3 base score of 10.0 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H). Improper handling of length parameter inconsistency in IPv4/ICMPv4 component when handling a packet sent by an unauthorized network attacker. This vulnerability may result in out-of-bounds Read.CVE-2020-11898 has been assigned to this vulnerability. A CVSS v3 base score of 9.1 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H). Improper input validation in IPv6 component when handling a packet sent by an unauthorized network attacker. This vulnerability may allow out-of-bounds Read and a possible Denial of Service.CVE-2020-11899 has been assigned to this vulnerability. A CVSS v3 base score of 5.4 has been calculated; the CVSS vector string is (AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L). Possible double free in IPv4 tunneling component when handling a packet sent by a network attacker. This vulnerability may result in use after free.CVE-2020-11900 has been assigned to this vulnerability. A CVSS v3 base score of 8.2 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:H). Improper input validation in DNS resolver component when handling a packet sent by an unauthorized network attacker. This vulnerability may result in remote code execution.CVE-2020-11901 has been assigned to this vulnerability. A CVSS v3 base score of 9.0 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H). Improper input validation in IPv6 over IPv4 tunneling component when handling a packet sent by an unauthorized network attacker. This vulnerability may allow out-of-bounds Read.CVE-2020-11902 has been assigned to this vulnerability. A CVSS v3 base score of 7.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L). Possible out-of-bounds read in DHCP component when handling a packet sent by an unauthorized network attacker. This vulnerability may allow exposure of sensitive information.CVE-2020-11903 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been calculated; the CVSS vector string is (AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N). Possible integer overflow or wraparound in memory allocation component when handling a packet sent by an unauthorized network attacker may result in out-of-bounds write.CVE-2020-11904 has been assigned to this vulnerability. A CVSS v3 base score of 5.6 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:L). Possible out-of-bounds read in DHCPv6 component when handling a packet sent by an unauthorized network attacker. This vulnerability may allow exposure of sensitive information.CVE-2020-11905 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been calculated; the CVSS vector string is (AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N). CVE-2020-11906 has been assigned to this vulnerability. A CVSS v3 base score of 5.0 has been calculated; the CVSS vector string is (AV:A/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:L).CVE-2020-11907 has been assigned to this vulnerability. A CVSS v3 base score of 5.0 has been calculated; the CVSS vector string is (AV:A/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:L). Improper handling of length parameter inconsistency in TCP component, from a packet sent by an unauthorized network attacker.CVE-2020-11908 has been assigned to this vulnerability. A CVSS v3 base score of 3.1 has been calculated; the CVSS vector string is (AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:L). Improper null termination in DHCP component when handling a packet sent by an unauthorized network attacker. This vulnerability may allow exposure of sensitive information.CVE-2020-11909 has been assigned to this vulnerability. A CVSS v3 base score of 3.7 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N). Improper input validation in IPv4 component when handling a packet sent by an unauthorized network attacker.CVE-2020-11910 has been assigned to this vulnerability. A CVSS v3 base score of 3.7 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N). Improper input validation in ICMPv4 component when handling a packet sent by an unauthorized network attacker. This vulnerability may allow out-of-bounds Read.CVE-2020-11911 has been assigned to this vulnerability. A CVSS v3 base score of 3.7 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:L). The affected product is vulnerable to improper access control, which may allow an attacker to change one specific configuration value.CVE-2020-11912 has been assigned to this vulnerability. A CVSS v3 base score of 3.7 has been calculated; the CVSS vector string is (AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:L). Improper input validation in TCP component when handling a packet sent by an unauthorized network attacker. This vulnerability may allow out-of-bounds Read..CVE-2020-11913 has been assigned to this vulnerability. A CVSS v3 base score of 3.7 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N). Improper input validation in IPv6 component when handling a packet sent by an unauthorized network attacker. This vulnerability may allow out-of-bounds Read.CVE-2020-11914 has been assigned to this vulnerability. A CVSS v3 base score of 3.1 has been calculated; the CVSS vector string is (AV:A/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N). | [] | null | null | 3.1 | null |
ICSA-20-175-03 | ABB Device Library Wizard | The software writes sensitive system information to an unprotected file, and a low-privileged user could read confidential data from such a file. This could allow the user to take control of the productCVE-2020-8482 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H). | [] | null | null | 7.8 | null |
ICSA-18-025-02B | Siemens Desigo PXC (Update C) | A remote attacker with network access to the device could potentially upload a new firmware image to the devices without prior authentication. CVE-2018-4834 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). | [] | null | null | 9.8 | null |
ICSA-22-137-01 | Circutor COMPACT DC-S BASIC | A buffer overflow vulnerability has been detected in the firewall function of the device management web portal. The device runs a CGI binary (index.cgi) to offer a management web application. Once authenticated with valid credentials in this web portal, a potential attacker could submit any "Address" value and it would be copied to a second variable with a "strcpy" vulnerable function without checking its length. Because of this, it is possible to send a long address value to overflow the process stack, controlling the function return address.CVE-2022-1669 has been assigned to this vulnerability. A CVSS v3 base score of 6.8 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:L/UI:N/S:U/C:N/I:H/A:H). | [] | null | null | 6.8 | null |
ICSA-24-130-03 | Delta Electronics InfraSuite Device Master | Delta Electronics InfraSuite Device Master contains a deserialization of untrusted data vulnerability because it runs a version of Apache ActiveMQ (5.15.2) which is vulnerable to CVE-2023-46604. | [] | null | 9.8 | null | null |
ICSMA-19-029-01 | Stryker Medical Beds | An industry-wide vulnerability exists in the WPA and WPA2 protocol affected by the Key Reinstallation Attacks known as KRACK. The four-way hand shake traffic in the Wi-Fi Protected Access WPA and WPA2 protocol can be manipulated to allow nonce reuse, resulting in key reinstallation. This could allow an attacker to execute a man-in-the-middle attack, enabling the attacker within radio range to replay, decrypt, or spoof frames. The following CVEs have been assigned to this group of vulnerabilities: CVE-2017-13077: Reinstallation of the pairwise key during the four-way handshake.. CVE-2017-13078: Reinstallation of the group key during the four-way handshake. CVE-2017-13078: Reinstallation of the group key during the four-way handshake.. CVE-2017-13079: Reinstallation of the Integrity Group Temporal Key (IGTK) during the four-way handshake.CVE-2017-13077: Reinstallation of the pairwise key during the four-way handshake. | [] | null | null | 6.8 | null |
ICSA-24-051-01 | Commend WS203VICM | A remote, unauthenticated attacker may be able to send crafted messages to the web server of the Commend WS203VICM causing the system to restart, interrupting service. A remote attacker may be able to bypass access control of Commend WS203VICM by creating a malicious request. A weak encoding is used to transmit credentials for WS203VICM. | [] | null | 5.7 | null | null |
ICSA-21-168-03 | Advantech WebAccess/SCADA (Update A) | The affected product is vulnerable to redirection, which may allow an attacker to send a maliciously crafted URL that could result in redirecting a user to a malicious webpage.CVE-2021-32956 has been assigned to this vulnerability. A CVSS v3 base score of 7.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L). The affected product is vulnerable to a directory traversal, which may allow an attacker to remotely read arbitrary files on the file system.CVE-2021-32954 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N). | [] | null | null | 6.5 | null |
ICSA-19-134-08 | Siemens SIMATIC PCS7, WinCC, TIA Portal (Update D) | An attacker with access to the project file could run arbitrary system commands with the privileges of the local database server. The vulnerability could be exploited by an attacker with access to the project file. The vulnerability does impact the confidentiality, integrity, and availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known. An attacker with local access to the project file could cause a Denial-of-Service condition on the affected product while the project file is loaded. Successful exploitation requires access to the project file. An attacker could use the vulnerability to compromise availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known. An authenticatd attacker with network access to the DCOM interface could execute arbitrary commands with SYSTEM privileges. The vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires authentication with a low-privileged user account and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity and availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known. | [] | null | null | 8.8 | null |
ICSA-24-074-05 | Siemens RUGGEDCOM APE1808 | A heap-based buffer overflow vulnerability in the SOCKS5 proxy handshake in the Curl package. If Curl is unable to resolve the address itself, it passes the hostname to the SOCKS5 proxy. However, the maximum length of the hostname that can be passed is 255 bytes. If the hostname is longer, then Curl switches to the local name resolving and passes the resolved address only to the proxy. The local variable that instructs Curl to "let the host resolve the name" could obtain the wrong value during a slow SOCKS5 handshake, resulting in the too-long hostname being copied to the target buffer instead of the resolved address, which was not the intended behavior. This flaw allows an attacker to insert cookies at will into a running program
using libcurl, if the specific series of conditions are met.
libcurl performs transfers. In its API, an application creates "easy handles"
that are the individual handles for single transfers.
libcurl provides a function call that duplicates en easy handle called
[curl_easy_duphandle](https://curl.se/libcurl/c/curl_easy_duphandle.html).
If a transfer has cookies enabled when the handle is duplicated, the
cookie-enable state is also cloned - but without cloning the actual
cookies. If the source handle did not read any cookies from a specific file on
disk, the cloned version of the handle would instead store the file name as
`none` (using the four ASCII letters, no quotes).
Subsequent use of the cloned handle that does not explicitly set a source to
load cookies from would then inadvertently load cookies from a file named
`none` - if such a file exists and is readable in the current directory of the
program using libcurl. And if using the correct file format of course. An improper privilege management vulnerability [CWE-269] in a Fortinet FortiOS HA cluster version 7.4.0 through 7.4.1 and 7.2.5 and in a FortiProxy HA cluster version 7.4.0 through 7.4.1 allows an authenticated attacker to perform elevated actions via crafted HTTP or HTTPS requests. The HTTP/2 protocol allows a denial of service (server resource consumption) because request cancellation can reset many streams quickly, as exploited in the wild in August through October 2023. An improper certificate validation vulnerability in Fortinet FortiOS 7.0.0 - 7.0.13, 7.2.0 - 7.2.6 and 7.4.0 - 7.4.1 allows a remote and unauthenticated attacker to perform a Man-in-the-Middle attack on the FortiLink communication channel between the FortiOS device and FortiSwitch. A out-of-bounds write in Fortinet FortiOS versions 7.4.0 through 7.4.2, 7.2.0 through 7.2.6, 7.0.0 through 7.0.13, 6.4.0 through 6.4.14, 6.2.0 through 6.2.15, 6.0.0 through 6.0.17, FortiProxy versions 7.4.0 through 7.4.2, 7.2.0 through 7.2.8, 7.0.0 through 7.0.14, 2.0.0 through 2.0.13, 1.2.0 through 1.2.13, 1.1.0 through 1.1.6, 1.0.0 through 1.0.7 allows attacker to execute unauthorized code or commands via specifically crafted requests A use of externally-controlled format string vulnerability [CWE-134] in FortiOS fgfmd daemon may allow a remote unauthenticated attacker to execute arbitrary code or commands via specially crafted requests. | [] | null | 9.8 | null | null |
ICSA-21-103-09 | Siemens LOGO! Soft Comfort | A zip slip vulnerability could be triggered while importing a compromised project file to the affected software. Chained with other vulnerabilities this vulnerability could ultimately lead to a system takeover by an attacker. The software insecurely loads libraries which makes it vulnerable to DLL hijacking. Successful exploitation by a local attacker could lead to a takeover of the system where the software is installed. | [] | null | 8.4 | null | null |
ICSA-18-212-02 | Johnson Controls Metasys and BCPro | This vulnerability results from improper error handling in HTTP-based communications with the server, which could allow an attacker to obtain technical information.CVE-2018-10624 has been assigned to this vulnerability. A CVSS v3 base score of 4.3 has been calculated; the CVSS vector string is (AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N). | [] | null | null | 4.3 | null |
ICSA-21-012-05 | Siemens SCALANCE X Products (Update B) | The vulnerability could allow an unauthenticated attacker to reboot the device over the network by using special urls from integrated web server of the affected products. The webserver of the affected devices contains a vulnerability that may lead to a heap overflow condition. An attacker could cause this condition on the webserver by sending specially crafted requests. This could stop the webserver temporarily. The web server of the affected devices contains a vulnerability that may lead to a buffer overflow condition. An attacker could cause this condition on the webserver by sending a specially crafted request. The webserver could stop and not recover anymore. | [] | null | 9.8 | null | null |
ICSA-23-331-01 | Delta Electronics InfraSuite Device Master | In Delta Electronics InfraSuite Device Master v.1.0.7, a vulnerability exists that allows an attacker to write to any file to any location of the filesystem, which could lead to remote code execution. In Delta Electronics InfraSuite Device Master v.1.0.7, a vulnerability exists that allows an unauthenticated attacker to execute code with local administrator privileges. In Delta Electronics InfraSuite Device Master v.1.0.7, a vulnerability exists that allows an unauthenticated attacker to execute arbitrary code through a single UDP packet. In Delta Electronics InfraSuite Device Master v.1.0.7, A vulnerability exists that allows an unauthenticated attacker to disclose user information through a single UDP packet, obtain plaintext credentials, or perform NTLM relaying. | [] | null | 7.5 | null | null |
ICSA-23-334-02 | Yokogawa STARDOM | This vulnerability may allow to a remote attacker to cause a denial-of-service condition to the FCN/FCJ controller by sending a crafted packet. While sending the packet, the maintenance homepage of the controller could not be accessed. Therefore, functions of the maintenance homepage, changing configuration, viewing logs, etc. are not available. But the controller's operation is not stopped by the condition. | [] | null | 5.3 | null | null |
ICSA-21-285-01 | Advantech WebAccess SCADA | An authenticated user can use API functions to disclose project names and paths from other users.CVE-2021-38431 has been assigned to this vulnerability. A CVSS v3 base score of 4.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N). | [] | null | null | 4.3 | null |
ICSA-19-155-03 | Geutebrück G-Cam and G-Code | A cross-site scripting vulnerability allows a remote authenticated attacker with access to event configuration to store malicious code on the server, which could later be triggered by a legitimate user resulting in code execution within the user 's browser.CVE-2019-10957 has been assigned to this vulnerability. A CVSS v3 base score of 6.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H). Using a specially crafted URL command, a remote authenticated user can execute commands as root.CVE-2019-10956 has been assigned to this vulnerability. A CVSS v3 base score of 7.2 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H). User input is not properly validated, which could allow a remote authenticated attacker with access to network configuration to supply system commands to the server, leading to remote code execution as root.CVE-2019-10958 has been assigned to this vulnerability. A CVSS v3 base score of 7.2 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H). | [] | null | null | 7.2 | null |
ICSA-23-103-01 | Siemens Adaptec Maxview Application | The Adaptec Maxview application on affected devices is using a non-unique TLS certificate across installations to protect the communication from the local browser to the local application.
A local attacker may use this key to decrypt intercepted local traffic between the browser and the application and could perform a man-in-the-middle attack in order to modify data in transit. | [] | null | 6.2 | null | null |
ICSA-24-011-10 | Siemens SIMATIC | In default installations of maxView Storage Manager where Redfish® server is configured for remote system management, a vulnerability has been identified that can provide unauthorized access. | [] | null | 10 | null | null |
ICSA-21-194-15 | ICSA-21-194-15_Siemens JT2Go and Teamcenter Visualization | The BMP_Loader.dll library in affected applications lacks proper validation of user-supplied data when parsing BMP files. A malformed input file could result in a double free of an allocated buffer that leads to a crash. An attacker could leverage this vulnerability to cause denial-of-service condition.CVE-2021-34333 has been assigned to this vulnerability. A CVSS v3 base score of 5.5 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H). The BMP_Loader.dll library in affected applications lacks proper validation of user-supplied data when parsing BMP files. A malformed input file could result in an infinite loop condition that leads to a denial-of-service condition. An attacker could leverage this vulnerability to consume excessive resources.CVE-2021-34332 has been assigned to this vulnerability. A CVSS v3 base score of 5.5 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H). The Jt981.dll library in affected applications lacks proper validation of user-supplied data when parsing JT files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-34331 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). The Jt981.dll library in affected applications lacks proper validation of user-supplied data prior to performing further free operations on an object when parsing JT files. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-34330 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). The affected product is vulnerable to a stack-based buffer overflow, which may allow an attacker to remotely execute arbitrary code. The plmxmlAdapterSE70.dll library in affected applications lacks proper validation of user-supplied data when parsing PAR files. This could result in an out-of-bounds write past the fixed-length heap-based buffer. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-34329 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). The plmxmlAdapterSE70.dll library in affected applications lacks proper validation of user-supplied data when parsing PAR files. This could result in an out-of-bounds write past the fixed-length heap-based buffer. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-34328 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). The plmxmlAdapterSE70.dll library in affected applications lacks proper validation of user-supplied data when parsing ASM files. This could result in an out-of-bounds write past the fixed-length heap-based buffer. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-34327 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). The plmxmlAdapterSE70.dll library in affected applications lacks proper validation of user-supplied data when parsing PAR files. This could result in an out-of-bounds write past the fixed-length heap-based buffer. An attacker could leverage this vulnerability to execute code in the context of the current process. CVE-2021-34326 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). The Jt981.dll library in affected applications lacks proper validation of user-supplied data when parsing JT files. This could result in an out-of-bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process. CVE-2021-34325 has been assigned to this vulnerability. A CVSS v3 base score of 3.3 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N). The Jt981.dll library in affected applications lacks proper validation of user-supplied data prior to performing further free operations on an object when parsing JT files. An attacker could leverage this vulnerability to execute code in the context of the current process. CVE-2021-34324 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). The Jt981.dll library in affected applications lacks proper validation of user-supplied data when parsing JT files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. CVE-2021-34323 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). The JPEG2K_Loader.dll library in affected applications lacks proper validation of user-supplied data when parsing J2K files. This could result in an out-of-bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process. CVE-2021-34322 has been assigned to this vulnerability. A CVSS v3 base score of 3.3 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N). The VisDraw.dll library in affected applications lacks proper validation of user-supplied data when parsing J2K files. This could result in an out-of-bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process.CVE-2021-34321 has been assigned to this vulnerability. A CVSS v3 base score of 3.3 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N). The Jt981.dll library in affected applications lacks proper validation of user-supplied data when parsing JT files. This could result in an out of bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process.CVE-2021-34320 has been assigned to this vulnerability. A CVSS v3 base score of 3.3 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N). The BMP_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing SGI files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-34319 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). The BMP_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing PCT files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-34318 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). The BMP_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing PCX files. This could result in an out-of-bounds write past the fixed-length heap-based buffer. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-34317 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). The DL180CoolType.dll library in affected applications lacks proper validation of user-supplied data when parsing PDF files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-34316 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). The BMP_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing SGI files. This could result in an out-of-bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-34315 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). The BMP_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing SGI files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-34314 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). The Tiff_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing TIFF files. This could result in an out-of-bounds write past the fixed-length heap-based buffer. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-34313 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). The Tiff_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing TIFF files. This could result in an out-of-bounds write past the fixed-length heap-based buffer. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-34312 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). The Mono_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing J2K files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-34311 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). The Tiff_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing TIFF files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-34310 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). The Tiff_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing TIFF files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-34309 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). The BMP_Loader.dll library in affected applications lacks proper validation of user-supplied data when parsing BMP files. This could result in an out-of-bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process.CVE-2021-34308 has been assigned to this vulnerability. A CVSS v3 base score of 3.3 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N). The Tiff_Loader.dll library in affected applications lacks proper validation of user-supplied data when parsing TIFF files. This could result in an out-of-bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process.CVE-2021-34307 has been assigned to this vulnerability. A CVSS v3 base score of 3.3 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N). The BMP_Loader.dll library in affected applications lacks proper validation of user-supplied data when parsing BMP files. This could result in a memory corruption condition. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-34306 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). The Gif_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing GIF files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-34305 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). The Tiff_Loader.dll library in affected applications lacks proper validation of user-supplied data when parsing TIFF files. This could result in an out-of-bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process.CVE-2021-34304 has been assigned to this vulnerability. A CVSS v3 base score of 3.3 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N). The Tiff_Loader.dll library in affected applications lacks proper validation of user-supplied data when parsing TIFF files. This could result in an out-of-bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process.CVE-2021-34303 has been assigned to this vulnerability. A CVSS v3 base score of 3.3 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N). The BMP_Loader.dll library in affected applications lacks proper validation of user-supplied data when parsing BMP files. This could result in an out-of-bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process.CVE-2021-34302 has been assigned to this vulnerability. A CVSS v3 base score of 3.3 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N). The BMP_Loader.dll library in affected applications lacks proper validation of user-supplied data prior to performing further free operations on an object when parsing BMP files. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-34301 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). The Tiff_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing TIFF files. This could result in an out-of-bounds write past the end of an allocated buffer. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-34300 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). The Tiff_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing TIFF files. This could result in an out-of-bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process.CVE-2021-34299 has been assigned to this vulnerability. A CVSS v3 base score of 3.3 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N). The BMP_Loader.dll library in affected applications lacks proper validation of user-supplied data prior to performing further free operations on an object when parsing BMP files. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-34298 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). The BMP_Loader.dll library in affected applications lacks proper validation of user-supplied data when parsing BMP files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-34297 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). The BMP_Loader.dll library in affected applications lacks proper validation of user-supplied data when parsing BMP files. This could result in an out-of-bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-34296 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). The Gif_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing GIF files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-34295 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). The Gif_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing GIF files. This could result in an out-of-bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-34294 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). The Gif_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing GIF files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-34293 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). The Tiff_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing TIFF files. This could result in an out-of-bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-34292 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). The Gif_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing GIF files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-34291 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). | [] | null | null | 7.8 | null |
ICSA-23-325-02 | Fuji Electric Tellus Lite V-Simulator | Stack-based buffer overflow may occur when Fuji Electric Tellus Lite V-Simulator parses a specially-crafted input file. When Fuji Electric Tellus Lite V-Simulator parses a specially-crafted input file an out of bounds write may occur. A user with a standard account in Fuji Electric Tellus Lite may overwrite files in the system. | [] | null | null | 7.3 | null |
ICSA-19-211-02 | Prima Systems FlexAir | The application incorrectly neutralizes special elements that could modify the intended OS command when it is sent to a downstream component, which could allow attackers to execute commands directly on the operating system.CVE-2019-7670 has been assigned to this vulnerability. A CVSS v3 base score of 10.0 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H). Improper validation of file extensions when uploading files could allow a remote authenticated attacker to upload and execute malicious applications within the application 's web root with root privileges.CVE-2019-7669 has been assigned to this vulnerability. A CVSS v3 base score of 9.1 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H). An unauthenticated user can send unverified HTTP requests, which may allow the attacker to perform certain actions with administrative privileges if a logged-in user visits a malicious website.CVE-2019-7281 has been assigned to this vulnerability. A CVSS v3 base score of 5.0 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:N/UI:R/S:U/C:L/I:L/A:L). The session-ID is of an insufficient length and can be exploited by brute force, which may allow a remote attacker to obtain a valid session and bypass authentication.CVE-2019-7280 has been assigned to this vulnerability. A CVSS v3 base score of 4.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N). Parameters sent to scripts are not properly sanitized before being returned to the user, which may allow an attacker to execute arbitrary code in a user 's browser session in context of an affected site.CVE-2019-7671 has been assigned to this vulnerability. A CVSS v3 base score of 5.4 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:N). The application generates database backup files with a predictable name, and an attacker can use brute force to identify the database backup file name. A malicious actor can exploit this issue to download the database file and disclose login information, which can allow the attacker to bypass authentication and have full access to the system.CVE-2019-7667 has been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N). The application allows improper authentication using the MD5 hash value of the password, which may allow an attacker with access to the database to login as admin without decrypting the password.CVE-2019-7666 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H). The flash version of the web interface contains a hard-coded username and password, which may allow an authenticated attacker to escalate privileges.CVE-2019-7672 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H). The application allows the upload of arbitrary Python scripts when configuring the main central controller. These scripts can be immediately executed because of root code execution, not as a web server user, allowing an authenticated attacker to gain full system access.CVE-2019-9189 has been assigned to this vulnerability. A CVSS v3 base score of 7.2 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H). | [] | null | null | 7.2 | null |
ICSA-22-069-06 | Siemens COMOS | Open Design Alliance Drawings SDK before 2021.12 contains a memory allocation with excessive size vulnerability while parsing specially crafted DGN files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-12019) Open Design Alliance Drawings SDK before 2021.12 contains a memory allocation with excessive size vulnerability while parsing specially crafted DGN files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-12026) Open Design Alliance Drawings SDK before 2021.11 contains a type conversion vulnerability while parsing specially crafted DXF and DWG files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-11912, ZDI-CAN-11993, ZDI-CAN-11988) Open Design Alliance Drawings SDK before 2021.11 contains a NULL pointer dereference vulnerability while parsing DXF and DWG files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-11913, ZDI-CAN-11989) Open Design Alliance Drawings SDK before 2021.11 contains a type confusion issue while parsing specially crafted DXF and DWG files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-11927) Open Design Alliance Drawings SDK before 2021.11 contains a stack-based buffer overflow vulnerability while parsing specially crafted DXF or DWG files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-11901, ZDI-CAN-12165, ZDI-CAN-12166) Open Design Alliance Drawings SDK before 2021.6 contains an out-of-bounds write issue while parsing specially crafted DXF files. This could result in a write past the end of an allocated buffer and allow an attacker to execute code in the context of the current process. (ZDI-CAN-11915) Open Design Alliance Drawings SDK before 2022.4 contains an out-of-bounds write issue while parsing specially crafted DXF files. This could result in a write past the end of an allocated buffer and allow an attacker to execute code in the context of the current process. (ZDI-CAN-13408) Open Design Alliance Drawings SDK before 2022.4 are vulnerable to an out-of-bounds read while parsing specially crafted DWG files. This could allow an attacker to read sensitive information from memory locations and to cause a denial of service (crash). (ZDI-CAN-13378) Open Design Alliance Drawings SDK before 2022.4 are vulnerable to an out-of-bounds read while parsing specially crafted DWG files. This could allow an attacker to read sensitive information from memory locations and to cause a denial of service. (ZDI-CAN-13412) Open Design Alliance Drawings SDK before 2021.11 contains a use-after-free vulnerability while parsing specially crafted DGN files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-13468, ZDI-CAN-13413) Open Design Alliance Drawings SDK before 2022.4 are vulnerable to improper check for unusual or exceptional conditions while parsing specially crafted DGN files. This could allow an attacker to cause a denial-of-service condition or execute code in the context of the current process. (ZDI-CAN-13411, ZDI-CAN-13409) Open Design Alliance Drawings SDK before 2022.4 contains an out-of-bounds write issue while parsing specially crafted DWG files. This could result in a write past the end of an allocated buffer and allow an attacker to execute code in the context of the current process. (ZDI-CAN-13410) Open Design Alliance Drawings SDK before 2022.4 are vulnerable to an out-of-bounds read while parsing specially crafted DXF files. This could allow an attacker to read sensitive information from memory locations and to cause a denial of service. (ZDI-CAN-13415) Open Design Alliance Drawings SDK before 2022.4 contains an out-of-bounds write issue while parsing specially crafted DGN files. This could result in a write past the end of an allocated buffer and allow an attacker to execute code in the context of the current process. (ZDI-CAN-13417) | [] | null | 7.8 | null | null |
ICSA-18-107-05 | ICSA-18-107-05_Rockwell Automation Stratix Industrial Managed Ethernet Switch | A format string vulnerability in the LLDP subsystem of Cisco IOS Software and Cisco IOS XE Software could allow an adjacent, unauthenticated attacker to cause a DoS condition or execute arbitrary code with elevated privileges.CVE-2018-0167 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is (AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). | [] | null | null | 8.8 | null |
ICSA-21-068-08 | Siemens Energy PLUSCONTROL 1st Gen | Initial Sequence Numbers (ISNs) for TCP connections are derived from an insufficiently random source. As a result, the ISN of current and future TCP connections could be predictable. An attacker could hijack existing sessions or spoof future ones. | [] | null | 6.5 | null | null |
ICSA-21-257-22 | Siemens Teamcenter Active Workspace | A path traversal vulnerability in the application could allow an attacker to bypass certain restrictions such as direct access to other services within the host. | [] | null | 4.5 | null | null |
ICSA-19-038-02 | Siemens EN100 Ethernet Module | Specially crafted packets to port 102/tcp could cause a denial-of-service condition in the affected products. A manual restart is required to recover the EN100 module functionality of the affected devices. Successful exploitation requires an attacker with network access to send multiple packets to the affected products or modules. As a precondition the IEC 61850-MMS communication needs to be activated on the affected products or modules. No user interaction or privileges are required to exploit the vulnerability. The vulnerability could allow causing a Denial-of-Service condition of the network functionality of the device, compromising the availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known. Specially crafted packets to port 102/tcp could cause a denial-of-service condition in the EN100 communication module if oscillographs are running. A manual restart is required to recover the EN100 module functionality. Successful exploitation requires an attacker with network access to send multiple packets to the EN100 module. As a precondition the IEC 61850-MMS communication needs to be activated on the affected EN100 modules. No user interaction or privileges are required to exploit the security vulnerability. The vulnerability could allow causing a Denial-of-Service condition of the network functionality of the device, compromising the availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known. | [] | null | null | 5.9 | null |
ICSA-17-234-01 | Automated Logic Corporation WebCTRL, i-VU, SiteScan | An unquoted search path vulnerability may allow a non-privileged local attacker to change files in the installation directory and execute arbitrary code with elevated privileges.CVE-2017-9644 has been assigned to this vulnerability. A CVSS v3 base score of 4.2 has been assigned; the CVSS vector string is (AV:L/AC:H/PR:L/UI:R/S:U/C:L/I:L/A:L). An authenticated attacker may be able to overwrite files that are used to execute code. This vulnerability does not affect version 6.5 of the software.CVE-2017-9640 has been assigned to this vulnerability. A CVSS v3 base score of 6.3 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L). An authenticated attacker may be able to upload a malicious file allowing the execution of arbitrary code.CVE-2017-9650 has been assigned to this vulnerability. A CVSS v3 base score of 8.3 has been assigned; the CVSS vector string is (AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:N). | [] | null | null | 8.3 | null |
ICSA-22-207-04 | MOXA NPort 5110 | The affected product is vulnerable to an out-of-bounds write that may allow an attacker to overwrite values in memory, causing a denial-of-service condition or potentially bricking the deviceCVE-2022-2044 has been assigned to this vulnerability. A CVSS v3 base score of 8.2 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:H). The affected product is vulnerable to an out-of-bounds write that can cause the device to become unresponsive.CVE-2022-2043 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H). | [] | null | null | 7.5 | null |
ICSA-19-192-05 | AVEVA Vijeo Citect and Citect SCADA Floating License Manager | A denial of service vulnerability related to preemptive item deletion in lmadmin and vendor daemon components allows a remote attacker to send a combination of messages to lmadmin or the vendor daemon, causing the heartbeat between lmadmin and the vendor daemon to stop and the vendor daemon to shut down. CVE-2018-20031 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H). A denial of service vulnerability related to message decoding in lmadmin and vendor daemon components allows a remote attacker to send a combination of messages to lmadmin or the vendor daemon, causing the heartbeat between lmadmin and the vendor daemon to stop and the vendor daemon to shut down. CVE-2018-20032 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H). A remote code execution vulnerability in lmadmin and vendor daemon components allows a remote attacker to corrupt the memory by allocating/deallocating memory, loading lmadmin or the vendor daemon and causing the heartbeat between lmadmin and the vendor daemon to stop. This would force the vendor daemon to shut down. No exploit of this vulnerability has been demonstrated. CVE-2018-20033 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). A denial of service vulnerability related to adding an item to a list in lmadmin and vendor daemon components allows a remote attacker to send a combination of messages to lmadmin or the vendor daemon, causing the heartbeat between lmadmin and the vendor daemon to stop and the vendor daemon to shut down. CVE-2018-20034 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H). | [] | null | null | 7.5 | null |
ICSA-17-208-03 | PDQ Manufacturing, Inc. LaserWash, Laser Jet and ProTouch | Affected web-server does not properly verify that provided authentication information is correct.CVE-2017-9630 has been assigned to this vulnerability. A CVSS v3 base score of 9.4 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H). Username and password are transmitted insecurely.CVE-2017-9632 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N). | [] | null | null | 7.5 | null |
ICSA-22-104-11 | Siemens SIMATIC Energy Manager | Affected applications improperly assign permissions to critical directories and files used by the application processes. This could allow a local unprivileged attacker to achieve code execution with ADMINISTRATOR or even NT AUTHORITY/SYSTEM privileges. A DLL Hijacking vulnerability could allow a local attacker to execute code with elevated privileges by placing a malicious DLL in one of the directories on the DLL search path. The affected system allows remote users to send maliciously crafted objects. Due to insecure deserialization of user-supplied content by the affected software, an unauthenticated attacker could exploit this vulnerability by sending a maliciously crafted serialized object. This could allow the attacker to execute arbitrary code on the device with SYSTEM privileges. | [] | null | 10 | null | null |
ICSMA-18-235-01 | BD Alaris Plus | The software does not perform authentication for functionality that requires a provable user identity.CVE-2018-14786 has been assigned to this vulnerability. A CVSS v3 base score of 9.4 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H). | [] | null | null | 9.4 | null |
ICSMA-20-261-01 | ICSMA-20-261-01_Philips Clinical Collaboration Platform | The product receives input or data, but it does not validate or incorrectly validates that the input has the properties required to process the data safely and correctly.CVE-2020-14506 has been assigned to this vulnerability. A CVSS v3 base score of 3.4 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:N). The software does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output used as a webpage that is served to other users.CVE-2020-14525 has been assigned to this vulnerability. A CVSS v3 base score of 3.5 has been calculated; the CVSS vector string is (AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N). When an attacker claims to have a given identity, the software does not prove or insufficiently proves the claim is correct.CVE-2020-16198 has been assigned to this vulnerability. A CVSS v3 base score of 5.0 has been calculated; the CVSS vector string is (AV:A/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:L). The software does not properly control the allocation and maintenance of a limited resource, thereby enabling an attacker to influence the amount of resources consumed, eventually leading to the exhaustion of available resources.CVE-2020-16200 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been calculated; the CVSS vector string is (AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H). The product exposes a resource to the wrong control sphere, providing unintended actors with inappropriate access to the resource.CVE-2020-16247 has been assigned to this vulnerability. A CVSS v3 base score of 6.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:H). | [] | null | null | 6.8 | null |
ICSA-23-166-09 | Siemens Solid Edge | Open Design Alliance Drawings SDK (versions before 2024.1) is vulnerable to an out-of-bounds read when reading a DWG file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19432) | [] | null | 7.8 | null | null |
ICSA-23-012-11 | Siemens Solid Edge before V2023 MP1 | The DOCMGMT.DLL contains a memory corruption vulnerability that could be triggered while parsing files in different file formats such as PAR, ASM, DFT. This could allow an attacker to execute code in the context of the current process. | [] | null | 7.8 | null | null |
ICSA-23-131-10 | Rockwell Automation Arena Simulation Software | Rockwell Automation Arena Simulation software v16.00 is vulnerable due to a memory buffer overflow, which could allow a malicious user to commit unauthorized arbitrary code. CVE-2023-29460 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been assigned; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). Rockwell Automation Arena Simulation software v16.00 is vulnerable due to a memory buffer overflow, which could allow a malicious user to commit unauthorized arbitrary code. CVE-2023-29461 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been assigned; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). Rockwell Automation Arena Simulation software v16.00 is vulnerable due to a memory buffer overflow, which could allow a malicious user to commit unauthorized arbitrary code. CVE-2023-29462 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been assigned; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). | [] | null | null | 7.8 | null |
ICSA-23-320-02 | Hitachi Energy MACH System Software | The McFeeder server (distributed as part of SSW package), is susceptible to an arbitrary file write vulnerability on the MAIN computer system. This vulnerability stems from the use of an outdated version of a third-party library, which is used to extract archives up-loaded to McFeeder server. An authenticated malicious client can exploit this vulnerability by uploading a crafted ZIP archive via the network to McFeeder's service endpoint. Authenticated clients can read arbitrary files on the MAIN Computer system using the remote procedure call (RPC) of the InspectSetup service endpoint. The low privilege client is then allowed to read arbitrary files that they do not have authorization to read. | [] | null | 2.7 | null | null |
ICSA-20-014-06 | OSIsoft PI Vision | The affected product is vulnerable to an improper access control, which may return unauthorized tag data when viewing analysis data reference attributes.CVE-2019-18275 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N). The affected product is vulnerable to a cross-site request forgery that may be introduced on the PI Vision administration site.CVE-2019-18271 has been assigned to this vulnerability. A CVSS v3 base score of 7.1 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:H). The affected product is vulnerable to cross-site scripting, which may allow invalid input to be introduced.CVE-2019-18273 has been assigned to this vulnerability. A CVSS v3 base score of 6.4 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:H/UI:R/S:U/C:H/I:H/A:H). The affected product records the service account password in the installation log files when a non-default service account and password are specified during installation or upgrade.CVE-2019-18244 has been assigned to this vulnerability. A CVSS v3 base score of 5.1 has been calculated; the CVSS vector string is (AV:L/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N). | [] | null | null | 5.1 | null |
ICSA-23-054-01 | PTC ThingWorx Edge | The affected products are vulnerable to an improper validation of array index, which could allow an attacker to crash the server and remotely execute arbitrary code. CVE-2023-0755 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). The affected products are vulnerable to an integer overflow or wraparound, which could allow an attacker to crash the server and remotely execute arbitrary code. CVE-2023-0754 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). | [] | null | null | 9.8 | null |
ICSA-23-285-09 | Siemens CPCI85 Firmware of SICAM A8000 Devices | The affected devices contain a hard-coded ID in the SSH `authorized_keys` configuration file. An attacker with knowledge of the corresponding private key could login to the device via SSH. Only devices with activated debug support are affected. | [] | null | 9.8 | null | null |
ICSA-17-283-01 | LAVA Computer MFG Inc. Ether-Serial Link | An improper authentication vulnerability has been identified, which, if exploited, would allow an attacker with the same IP address to bypass authentication by accessing a specific uniform resource locator.CVE-2017-14003 has been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H). | [] | null | null | 8.1 | null |
ICSA-20-252-01 | Siemens SIMATIC RTLS Locating Manager | The start-stop scripts for the services of the affected application could allow a local attacker to include arbitrary commands that are executed when services are started or stopped interactively by system administrators. The directory of service executables of the affected application could allow a local attacker to include arbitrary commands that are executed with SYSTEM privileges when the system restarts. Multiple services of the affected application are executed with SYSTEM privileges while the call path is not quoted. This could allow a local attacker to inject arbitrary commands that are execeuted instead of the legitimate service. | [] | null | 8.4 | null | null |
ICSA-19-092-01 | Advantech WebAccess/SCADA | Multiple command injection vulnerabilities, caused by a lack of proper validation of user-supplied data, may allow remote code execution.CVE-2019-6552 has been assigned to these vulnerabilities. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H) Multiple stack-based buffer overflow vulnerabilities, caused by a lack of proper validation of the length of user-supplied data, may allow remote code execution.CVE-2019-6550 has been assigned to these vulnerabilities. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). An improper access control vulnerability may allow an attacker to cause a denial-of-service condition.CVE-2019-6554 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H) | [] | null | null | 7.5 | null |
ICSA-24-074-03 | Siemens SINEMA Remote Connect Server | Cross Site Scripting vulnerability in jQuery 2.2.0 through 3.x before 3.5.0 allows a remote attacker to execute arbitrary code via the <options> element. The affected application consists of a web service that lacks proper access control for some of the endpoints. This could lead to unauthorized access to resources and potentially lead to code execution. | [] | null | 9.8 | null | null |
ICSA-23-024-02 | SOCOMEC MODULYS GP (UPDATE A) | SOCOMEC MODULYS GP Netvision versions 7.20 and prior lack strong encryption for credentials on HTTP connections, which could result in threat actors obtaining sensitive information. | [] | null | null | 5.7 | null |
ICSA-20-324-03 | Real Time Automation EtherNet/IP | The affected product is vulnerable to a stack-based buffer overflow, which may allow an attacker to send a specially crafted packet that may result in a denial-of-service condition or code execution.CVE-2020-25159 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). | [] | null | null | 9.8 | null |
ICSA-19-031-01 | Schneider Electric EVLink Parking | A hard-coded credentials vulnerability exists that could enable an attacker to gain access to the device.CVE-2018-7800 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). A code injection vulnerability exists that could allow remote code execution with maximum privileges.CVE-2018-7801 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). A SQL injection vulnerability exists that could give an attacker access to the web interface with full privileges.CVE-2018-7802 has been assigned to this vulnerability. A CVSS v3 base score of 6.4 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:N). | [] | null | null | 6.4 | null |
ICSA-22-055-03 | Schneider Electric Easergy P5 and P3 | If an attacker were to obtain the SSH cryptographic key for the device and take active control of the local operational network connected to this product, they could observe and manipulate traffic associated with product configuration. This could result in information disclosure. CVE-2022-22722 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H). A buffer copy without checking size of input vulnerability exists in Easergy P5 devices that could lead to a buffer overflow, causing program crashes and arbitrary code execution when specially crafted packets are sent to the device over the network. Protection functions and tripping functions via GOOSE can be impacted. CVE-2022-22723 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is (AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). A buffer copy without checking size of input vulnerability exists in Easergy P3 devices that could lead to a buffer overflow, causing program crashes and arbitrary code execution when specially crafted packets are sent to the device over the network. Protection functions and tripping functions via GOOSE can be impacted. CVE-2022-22725 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is (AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). An Improper Input Validation vulnerability exists in Easergy P5 devices that cause the device watchdog function to be disabled if the attacker had access to privileged user credentials. CVE-2022-34758 has been assigned to this vulnerability. A CVSS v3 base score of 5.1 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:L). | [] | null | null | 5.1 | null |
ICSA-18-156-01 | ABB IP Gateway | By accessing a specific uniform resource locator (URL) on the web server, a malicious user is able to access the configuration files and application pages without authentication.CVE-2017-7931 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). The web server does not sufficiently verify that a request was performed by the authenticated user, which may allow an attacker to launch a request impersonating that user.CVE-2017-7906 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). Some configuration files contain passwords stored in plain-text, which may allow an attacker to gain unauthorized access.CVE-2017-7933 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). | [] | null | null | 9.8 | null |
ICSA-18-284-03 | Delta Industrial Automation TPEditor | Multiple stack-based buffer overflow vulnerabilities may be exploited by processing specially crafted project files lacking user input validation before copying data from project files onto the stack and may allow an attacker to remotely execute arbitrary code.CVE-2018-17929 has been assigned to this vulnerability. A CVSS v3 base score of 6.6 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:H). Multiple out-of-bounds write vulnerabilities may be exploited by processing specially crafted project files lacking user input validation, which may cause the system to write outside the intended buffer area and may allow remote code execution.CVE-2018-17927 has been assigned to this vulnerability. A CVSS v3 base score of 6.6 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:H). | [] | null | null | 6.6 | null |
ICSA-22-242-07 | Honeywell Experion LX | The affected product uses the EpicMo protocol that does not have authentication features, which may allow an attacker with access to this protocol over a network to manipulate firmware or cause a denial-of-service condition.CVE-2022-30317 has been assigned to this vulnerability. A CVSS v3 base score of 9.1 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H). | [] | null | null | 9.1 | null |
ICSA-19-227-01 | Johnson Controls Metasys | Metasys ADS/ADX servers and NAE/NIE/NCE engines make use of a shared RSA key pair for certain encryption operations involving the Site Management Portal (SMP). An attacker with access to the shared RSA key pair could decrypt captured network traffic between the Metasys ADS/ADX servers or NAE/NIE/NCE engines and the connecting SMP user client.CVE-2019-7593 has been assigned to this vulnerability. A CVSS v3 base score of 6.8 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:N). Metasys ADS/ADX servers and NAE/NIE/NCE engines make use of a hardcoded RC2 key for certain encryption operations involving the Site Management Portal (SMP). An attacker with access to the hardcoded RC2 key could decrypt captured network traffic between the Metasys ADS/ADX servers or NAE/NIE/NCE engines and the connecting SMP user client.CVE-2019-7594 has been assigned to this vulnerability. A CVSS v3 base score of 6.8 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:N). | [] | null | null | 6.8 | null |
ICSA-23-110-01 | INEA ME RTU | Versions of INEA ME RTU firmware prior to 3.36 are vulnerable to OS command injection, which could allow an attacker to remotely execute arbitrary code. CVE-2023-2131 has been assigned to this vulnerability. A CVSS v3 base score of 10.0 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H). | [] | null | null | 10 | null |
ICSA-18-242-01 | Philips e-Alert Unit | The software does not validate input properly, allowing an attacker to craft the input in a form that is not expected by the rest of the application. This would lead to parts of the unit receiving unintended input, which may result in altered control flow, arbitrary control of a resource, or arbitrary code execution.CVE-2018-8850 has been assigned to this vulnerability. A CVSS v3 base score of 7.1 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:H/A:N). The software does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output that is used as a web page that is then served to other users.CVE-2018-8846 has been assigned to this vulnerability. A CVSS v3 base score of 7.1 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:H/A:N). The Philips e-Alert contains a banner disclosure vulnerability that could allow attackers to obtain extraneous product information, such as OS and software components, via the HTTP response header that is normally not available to the attacker, but might be useful information in an attack.CVE-2018-14803has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N). The software, upon installation, sets incorrect permissions for an object that exposes it to an unintended actor.CVE-2018-8848 has been assigned to this vulnerability. A CVSS v3 base score of 7.1 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:H/A:N). The software transmits sensitive or security-critical data in cleartext in a communication channel that can be sniffed by unauthorized actors. The Philips e-Alert communication channel is not encrypted which could therefore lead to disclosure of personal contact information and application login credentials from within the same subnet.CVE-2018-8842 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N). The web application does not, or cannot, sufficiently verify whether a well-formed, valid, consistent request was intentionally provided by the user who submitted the request.CVE-2018-8844 has been assigned to this vulnerability. A CVSS v3 base score of 6.8 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:N/UI:R/S:U/C:N/I:H/A:H). When authenticating a user or otherwise establishing a new user session, the software gives an attacker the opportunity to steal authenticated sessions without invalidating any existing session identifier.CVE-2018-8852 has been assigned to this vulnerability. A CVSS v3 base score of 6.4 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:H/UI:R/S:U/C:H/I:H/A:H). The software does not properly restrict the size or amount of resources requested or influenced by an actor, which can be used to consume more resources than intended.CVE-2018-8854 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H). | [] | null | null | 7.5 | null |
ICSA-18-128-01 | Siemens Medium Voltage SINAMICS Products (Update A) | Specially crafted PROFINET DCP broadcast packets could cause a Denial-of-Service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected. Specially crafted packets sent to port 161/udp could cause a Denial-of-Service condition. The affected devices must be restarted manually. | [] | null | 7.5 | null | null |
ICSA-21-012-04 | Siemens Solid Edge | Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds write into uninitialized memory. An attacker could leverage this vulnerability to execute code in the context of the current process. Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in a out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. Affected applications lack proper validation of user-supplied data when parsing PAR files. This can result in an out of bounds write past the memory location that is a read only image address. An attacker could leverage this vulnerability to execute code in the context of the current process. Affected applications lack proper validation of user-supplied data when parsing PAR files. This could lead to a stack based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of the current process. Affected applications lack proper validation of user-supplied data when parsing DFT files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. Affected applications lack proper validation of user-supplied data when parsing of PAR files. This could result in a stack based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of the current process. | [] | null | 7.8 | null | null |
ICSA-23-103-08 | Siemens Mendix Forgot Password Module | Affected products contain a path traversal vulnerability that could allow the creation or overwrite of arbitrary files in the engineering system. If the user is tricked to open a malicious PC system configuration file, an attacker could exploit this vulnerability to achieve arbitrary code execution. | [] | null | 7.3 | null | null |
ICSA-18-254-04 | Siemens SIMATIC WinCC OA | Improper access control to a data point of the affected product could allow an unauthenticated remote user to escalate its privileges in the context of SIMATIC WinCC OA V3.14. This vulnerability could be exploited by an attacker with network access to port 5678/TCP of the SIMATIC WinCC OA V3.14 server. Successful exploitation requires no user privileges and no user interaction. This vulnerability could allow an attacker to compromise integrity and availability of the SIMATIC WinCC OA system. At the time of advisory publication no public exploitation of this vulnerability was known. | [] | null | null | 9.1 | null |
ICSA-19-344-06 | Siemens SIMATIC S7-1200 and S7-1500 CPU Families (Update B) | An attacker in a man-in-the-middle position could modify network traffic exchanged on Port 102/TCP, due to certain properties in the calculation used for integrity protection. CVE-2019-10929 has been assigned to this vulnerability. A CVSS v3 base score of 3.7 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:L/A:N). An attacker with network access to Port 102/TCP could modify the user program on the PLC in a way that the running code is different from the source code stored on the device. CVE-2019-10943 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N). | [] | null | null | 5.3 | null |
ICSA-22-342-02 | AVEVA InTouch Access Anywhere and Plant SCADA Access Anywhere | AVEVA InTouch Access Anywhere versions 2020 R2 and older are vulnerable to a path traversal exploit that could allow an unauthenticated user with network access to read files on the system outside of the secure gateway web server. CVE-2022-23854 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N). AVEVA InTouch Access Anywhere versions 2023 and prior and Plant SCADA Access Anywhere versions 2020 R2 and prior use outdated OpenSSL versions that are vulnerable to a classic buffer overflow, which could allow an attacker to create denial-of-service conditions or execute arbitrary code. CVE-2021-3711 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). AVEVA InTouch Access Anywhere versions 2023 and prior and Plant SCADA Access Anywhere versions 2020 R2 and prior use versions of jQuery vulnerable to cross-site scripting. Passing HTML from untrusted sources—even after sanitizing it—to one of jQuery's DOM manipulation methods (i.e. .html(), .append(), and others) may execute untrusted code in jQuery versions greater than or equal to 1.2 and before 3.5.0. CVE-2020-11022 has been assigned to this vulnerability. A CVSS v3 base score of 6.1 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N). | [] | null | null | 6.1 | null |
ICSA-18-317-02 | Siemens S7-400 CPUs (Update B) | Specially crafted packets sent to port 102/tcp via Ethernet interface, via
PROFIBUS, or via Multi Point Interfaces (MPI) could cause the affected
devices to go into defect mode. Manual reboot is required to resume normal
operation.
Successful exploitation requires an attacker to be able to send specially
crafted packets to port 102/tcp via Ethernet interface, via PROFIBUS or Multi
Point Interfaces (MPI). No user interaction and no user privileges are
required to exploit the security vulnerability. The vulnerability could allow
causing a denial of service condition of the core functionality of the CPU,
compromising the availability of the system. CVE-2018-16556 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H). Sending of specially crafted packets to port 102/tcp via Ethernet interface
via PROFIBUS or Multi Point Interfaces (MPI) could cause a denial of service
condition on affected devices. Flashing with a firmware image may be required
to recover the CPU.
Successful exploitation requires an attacker to have network access to port
102/tcp via Ethernet interface or to be able to send messages via PROFIBUS or
Multi Point Interfaces (MPI) to the device. No user interaction is required.
If no access protection is configured, no privileges are required to exploit
the security vulnerability. The vulnerability could allow causing a
denial of service condition of the core functionality of the CPU,
compromising the availability of the system. CVE-2018-16557 has been assigned to this vulnerability. A CVSS v3 base score of 8.2 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:H). | [] | null | 8.2 | null | null |
ICSA-21-131-08 | Siemens Tecnomatix Plant Simulation | The PlantSimCore.dll library lacks proper validation of user-supplied data when parsing SPP files. This could result in a stack based buffer overflow, a different vulnerability than CVE-2021-27398.
An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13279) The PlantSimCore.dll library lacks proper validation of user-supplied data when parsing SPP files. This could result in a memory corruption condition.
An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13287) The PlantSimCore.dll library lacks proper validation of user-supplied data when parsing SPP files. This could result in a stack based buffer overflow, a different vulnerability than CVE-2021-27396.
An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13290) | [] | null | 7.8 | null | null |
ICSA-21-147-03 | MesaLabs AmegaView | The affected product is vulnerable to a command injection, which may allow an attacker to remotely execute arbitrary code.CVE-2021-27447 has been assigned to this vulnerability. A CVSS v3 base score of 10.0 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H). The affected product 's passcode is generated by an easily reversible algorithm, which may allow an attacker to gain access to the device.CVE-2021-27451 has been assigned to this vulnerability. A CVSS v3 base score of 7.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L). The affected product uses default cookies that could be set to bypass authentication to the web application, which may allow an attacker to gain access.CVE-2021-27453 has been assigned to this vulnerability. A CVSS v3 base score of 7.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L). The affected product has a command injection vulnerability that can be exploited to execute commands in the web server.CVE-2021-27449 has been assigned to this vulnerability. A CVSS v3 base score of 9.9 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H). The affected product has insecure file permissions that could be exploited to escalate privileges on the device.CVE-2021-27445 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H). | [] | null | null | 7.8 | null |
ICSA-23-236-06 | Rockwell Automation Select Distributed I/O Communication Modules | Pyramid Solutions' affected products, the Developer and DLL kits for EtherNet/IP Adapter and EtherNet/IP Scanner may be vulnerable to an out-of-bounds write, which may allow an unauthorized threat actor to send a specially crafted packet that may result in a denial-of-service condition. | [] | null | null | 8.6 | null |
ICSA-23-012-06 | Johnson Controls Metasys | Under certain circumstances, the affected versions of Johnson Controls Metasys ADS/ADX/OAS Servers could expose plaintext credentials through application programmable interface (API) calls.-CVE-2021-36204 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been assigned; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). | [] | null | null | 7.8 | null |
ICSA-18-151-03 | Yokogawa STARDOM Controllers (Update A) | The affected controllers utilize hard-coded credentials that could allow an attacker to gain unauthorized administrative access to the device, which could result in remote code execution.CVE-2018-10592 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). The web application improperly protects credentials which could allow an attacker to obtain credentials for remote access to controllers.CVE-2018-17900 has been assigned to this vulnerability. A CVSS v3 base score of 9.4 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L). The application utilizes multiple methods of session management which could result in a denial of service to the remote management functions.CVE-2018-17902 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L). The affected controllers utilize hard-coded credentials which may allow an attacker gain unauthorized access to the maintenance functions and obtain or modify information. This attack can be executed only during maintenance work.CVE-2018-17896 has been assigned to this vulnerability. A CVSS v3 base score of 8.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:L). The controller application fails to prevent memory exhaustion by unauthorized requests. This could allow an attacker to cause the controller to become unstable.CVE-2018-17898 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L). | [] | null | null | 5.3 | null |
ICSA-17-220-02 | Moxa SoftNVR-IA Live Viewer | An uncontrolled search path element (DLL Hijacking) vulnerability has been identified.To exploit this vulnerability, an attacker could rename a malicious DLL to meet the criteria of the application, and the application would not verify that the DLL is correct. The attacker needs to have administrative access to the default install location in order to plant the insecure DLL. Once loaded by the application, the DLL could run malicious code at the privilege level of the application. | [] | null | null | 7.2 | null |
ICSA-20-224-07 | Siemens Automation License Manager | The application does not properly validate the users' privileges when executing some operations, which could allow a user with low permissions to arbitrary modify files that should be protected against writing. | [] | null | 7.3 | null | null |
ICSA-22-258-05 | Siemens SINEC INS | The package ua-parser-js before 0.7.23 are vulnerable to Regular Expression Denial of Service (ReDoS) in multiple regexes (see linked commit for more info). json-c through 0.14 has an integer overflow and out-of-bounds write via a large JSON file, as demonstrated by printbuf_memappend. Axios NPM package 0.21.0 contains a Server-Side Request Forgery (SSRF) vulnerability where an attacker is able to bypass a proxy by providing a URL that responds with a redirect to a restricted host or IP address. Lodash versions prior to 4.17.21 are vulnerable to Regular Expression Denial of Service (ReDoS) via the toNumber, trim and trimEnd functions. axios is vulnerable to Inefficient Regular Expression Complexity There is a carry propagation bug in the MIPS32 and MIPS64 squaring procedure. Many EC algorithms are affected, including some of the TLS 1.3 default curves. Impact was not analyzed in detail, because the pre-requisites for attack are considered unlikely and include reusing private keys. Analysis suggests that attacks against RSA and DSA as a result of this defect would be very difficult to perform and are not believed likely. Attacks against DH are considered just feasible (although very difficult) because most of the work necessary to deduce information about a private key may be performed offline. The amount of resources required for such an attack would be significant. However, for an attack on TLS to be meaningful, the server would have to share the DH private key among multiple clients, which is no longer an option since CVE-2016-0701. This issue affects OpenSSL versions 1.0.2, 1.1.1 and 3.0.0. It was addressed in the releases of 1.1.1m and 3.0.1 on the 15th of December 2021. For the 1.0.2 release it is addressed in git commit 6fc1aaaf3 that is available to premium support customers only. It will be made available in 1.0.2zc when it is released. The issue only affects OpenSSL on MIPS platforms. Fixed in OpenSSL 3.0.1 (Affected 3.0.0). Fixed in OpenSSL 1.1.1m (Affected 1.1.1-1.1.1l). Fixed in OpenSSL 1.0.2zc-dev (Affected 1.0.2-1.0.2zb). Lodash versions prior to 4.17.21 are vulnerable to Command Injection via the template function. OpenSSL 1.0.2 supports SSLv2. If a client attempts to negotiate SSLv2 with a server that is configured to support both SSLv2 and more recent SSL and TLS versions then a check is made for a version rollback attack when unpadding an RSA signature. Clients that support SSL or TLS versions greater than SSLv2 are supposed to use a special form of padding. A server that supports greater than SSLv2 is supposed to reject connection attempts from a client where this special form of padding is present, because this indicates that a version rollback has occurred (i.e. both client and server support greater than SSLv2, and yet this is the version that is being requested). The implementation of this padding check inverted the logic so that the connection attempt is accepted if the padding is present, and rejected if it is absent. This means that such as server will accept a connection if a version rollback attack has occurred. Further the server will erroneously reject a connection if a normal SSLv2 connection attempt is made. Only OpenSSL 1.0.2 servers from version 1.0.2s to 1.0.2x are affected by this issue. In order to be vulnerable a 1.0.2 server must: 1) have configured SSLv2 support at compile time (this is off by default), 2) have configured SSLv2 support at runtime (this is off by default), 3) have configured SSLv2 ciphersuites (these are not in the default ciphersuite list) OpenSSL 1.1.1 does not have SSLv2 support and therefore is not vulnerable to this issue. The underlying error is in the implementation of the RSA_padding_check_SSLv23() function. This also affects the RSA_SSLV23_PADDING padding mode used by various other functions. Although 1.1.1 does not support SSLv2 the RSA_padding_check_SSLv23() function still exists, as does the RSA_SSLV23_PADDING padding mode. Applications that directly call that function or use that padding mode will encounter this issue. However since there is no support for the SSLv2 protocol in 1.1.1 this is considered a bug and not a security issue in that version. OpenSSL 1.0.2 is out of support and no longer receiving public updates. Premium support customers of OpenSSL 1.0.2 should upgrade to 1.0.2y. Other users should upgrade to 1.1.1j. Fixed in OpenSSL 1.0.2y (Affected 1.0.2s-1.0.2x). The OpenSSL public API function X509_issuer_and_serial_hash() attempts to create a unique hash value based on the issuer and serial number data contained within an X509 certificate. However it fails to correctly handle any errors that may occur while parsing the issuer field (which might occur if the issuer field is maliciously constructed). This may subsequently result in a NULL pointer deref and a crash leading to a potential denial of service attack. The function X509_issuer_and_serial_hash() is never directly called by OpenSSL itself so applications are only vulnerable if they use this function directly and they use it on certificates that may have been obtained from untrusted sources. OpenSSL versions 1.1.1i and below are affected by this issue. Users of these versions should upgrade to OpenSSL 1.1.1j. OpenSSL versions 1.0.2x and below are affected by this issue. However OpenSSL 1.0.2 is out of support and no longer receiving public updates. Premium support customers of OpenSSL 1.0.2 should upgrade to 1.0.2y. Other users should upgrade to 1.1.1j. Fixed in OpenSSL 1.1.1j (Affected 1.1.1-1.1.1i). Fixed in OpenSSL 1.0.2y (Affected 1.0.2-1.0.2x). The affected products contain the third party component, ISC DHCP, that possesses a vulnerability if used as a DHCP client or server. The vulnerability affects the DHCP package when storing and reading DHCP lease information containing particular option information.
An attacker could exploit this vulnerability to affect the availability of the DHCP client or server, or in the worst case affect the confidentiality or integrity of device through a buffer overflow or cause a remote-code execution. BIND 9.11.0 -> 9.11.36 9.12.0 -> 9.16.26 9.17.0 -> 9.18.0 BIND Supported Preview Editions: 9.11.4-S1 -> 9.11.36-S1 9.16.8-S1 -> 9.16.26-S1 Versions of BIND 9 earlier than those shown - back to 9.1.0, including Supported Preview Editions - are also believed to be affected but have not been tested as they are EOL. The cache could become poisoned with incorrect records leading to queries being made to the wrong servers, which might also result in false information being returned to clients. follow-redirects is vulnerable to Exposure of Private Personal Information to an Unauthorized Actor node-fetch is vulnerable to Exposure of Sensitive Information to an Unauthorized Actor BIND 9.16.11 -> 9.16.26, 9.17.0 -> 9.18.0 and versions 9.16.11-S1 -> 9.16.26-S1 of the BIND Supported Preview Edition. Specifically crafted TCP streams can cause connections to BIND to remain in CLOSE_WAIT status for an indefinite period of time, even after the client has terminated the connection. | [] | null | 5.3 | null | null |