ICSMA-20-212-01
Philips DreamMapper
Information written to log files can give guidance to a potential attacker.CVE-2020-14518 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N).
[]
null
null
5.3
null
ICSMA-18-144-01
BeaconMedaes TotalAlert Scroll Medical Air Systems
An attacker with network access to the integrated web server could retrieve default or user defined credentials stored and transmitted in an insecure manner.CVE-2018-7518 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N). Passwords are presented in plaintext in a file that is accessible without authentication.CVE-2018-7510 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N).
[]
null
null
7.5
null
ICSA-23-131-14
Rockwell Automation PanelView 800
The affected product is vulnerable to an out-of-bounds write, which could allow an attacker to accomplish a heap buffer overflow if the user has the email feature enabled in the project file WolfSSL uses. This feature is disabled by default. CVE-2020-36177 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). The affected product is vulnerable to an out-of-bounds read, which could allow an attacker to accomplish a heap buffer overflow if the user has the email feature enabled in the project file WolfSSL uses. This feature is disabled by default. CVE-2019-16748 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).
[]
null
7.8
null
null
ICSA-17-313-01
AutomationDirect CLICK, C-More, C-More Micro, Do-more Designer, GS Drives, SL-Soft SOLO, DirectSOFT (Update B)
An uncontrolled search path element (DLL Hijacking) vulnerability has been identified. To exploit this vulnerability, an attacker could rename a malicious DLL to meet the criteria of the application, and the application would not verify that the DLL is correct. Once loaded by the application, the DLL could run malicious code at the privilege level of the application.CVE-2017-14020 has been assigned to this vulnerability. A CVSS v3 base score of 6.7 has been calculated; the CVSS vector string is (AV:L/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H).
[]
null
null
6.7
null
ICSA-24-046-03
Siemens SIMATIC RTLS Gateways
The Treck TCP/IP stack on affected devices improperly handles length parameter inconsistencies. Unauthenticated remote attackers may be able to send specially crafted IP packets which could lead to a denial of service condition or remote code execution.
[]
null
7.5
null
null
ICSA-21-068-09
Siemens Solid Edge File Parsing
Affected applications lack proper validation of user-supplied data when parsing DFT files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12049) When opening a specially crafted SEECTCXML file, the application could disclose arbitrary files to remote attackers. This is because of the passing of specially crafted content to the underlying XML parser without taking proper restrictions such as prohibiting an external dtd. (ZDI-CAN-11923) Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12532) Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds read past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12534)
[]
null
7.8
null
null
ICSA-22-144-02
Matrikon OPC Server
The affected product is vulnerable to a condition where a low-privileged user allowed to connect to the OPC server to use the functions of the IPersisFile can execute operating system processes with system-level privileges.CVE-2022-1261 has been assigned to this vulnerability. A CVSS v3 base score of 5.8 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:L/UI:R/S:C/C:N/I:H/A:N).
[]
null
null
5.8
null
ICSA-23-222-08
Resource Allocation in Siemens RUGGEDCOM
The web server of the affected devices contains a vulnerability that may lead to a denial of service condition. An attacker may cause total loss of availability of the web server, which might recover after the attack is over.
[]
null
7.5
null
null
ICSA-18-142-01
Martem TELEM-GW6/GWM (Update B)
The RTU does not perform authentication of IEC-104 control commands, which may allow a rogue node a remote control of the industrial process.CVE-2018-10603 has been assigned to this vulnerability. A CVSS v3 base score of 10.0 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L). Using default credentials to connect to the RTU, unprivileged user may modify/upload a new system configuration or take the full control over the RTU.CVE-2018-10605 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H). Creating new connections to one or more IOAs, without closing them properly, may cause a denial of service within the industrial process control channel.CVE-2018-10607 has been assigned to this vulnerability. A CVSS v3 base score of 8.2 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:H). Improper sanitization of data over a Websocket may allow cross-site scripting and client-side code execution with target user privileges.CVE-2018-10609 has been assigned to this vulnerability. A CVSS v3 base score of 7.4 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:R/S:C/C:N/I:H/A:N).
[]
null
null
7.4
null
ICSA-18-128-03
Siemens Siveillance VMS Video Mobile App
Improper certificate validation could allow an attacker in a privileged network position to read data from and write data to the encrypted communication channel between the app and a server. The security vulnerability could be exploited by an attacker in a privileged network position which allows intercepting the communication channel between the affected app and a server (such as Man-in-the-Middle). Furthermore, an attacker must be able to generate a certificate that results for the validation algorithm in a checksum identical to a trusted certificate. Successful exploitation requires no user interaction. The vulnerability could allow reading data from and writing data to the encrypted communication channel between the app and a server, impacting the communication's confidentiality and integrity. At the time of advisory publication no public exploitation of this security vulnerability was known. Siemens confirms the security vulnerability and provides mitigations to resolve the security issue.
[]
null
null
4.8
null
ICSA-21-315-01
WECON PLC Editor
The affected product is vulnerable to a stack-based buffer overflow while processing project files, which may allow an attacker to execute arbitrary code.CVE-2021-42705 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). The affected product is vulnerable to an out-of-bounds write while processing project files, which may allow an attacker to execute arbitrary code.CVE-2021-42707 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).
[]
null
null
7.8
null
ICSA-23-047-12
Siemens JT Open, JT Utilities, and Parasolid
The affected application contains a stack overflow vulnerability while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process. The affected application contains a memory corruption vulnerability while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process. The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.
[]
null
7.8
null
null
ICSA-21-194-03
Siemens PROFINET Devices (Update D)
Affected devices contain a vulnerability that allows an unauthenticated attacker to trigger a denial-of-service condition. The vulnerability can be triggered if a large amount of DCP reset packets are sent to the device.
[]
null
7.5
null
null
ICSA-24-275-02
Mitsubishi Electric MELSEC iQ-F FX5-OPC
A Denial-of-Service (DoS) vulnerability due to NULL Pointer Dereference when processing PKCS#12 format certificate exists in OpenSSL installed on MELSEC iQ-F OPC UA Unit. Because OpenSSL does not correctly check if a certain field in the PKCS#12 format certificate is NULL, a NULL pointer dereference occurs when the field is NULL, causing the product to enter a denial-of-service condition.
[]
null
7.5
null
null
ICSA-24-030-05
Rockwell Automation ControlLogix and GuardLogix
A Denial-of-Service (DoS) vulnerability exists in the affected products, listed above. If exploited, the product could potentially experience a major nonrecoverable fault (MNRF). The device will restart itself to recover from the MNRF.
[]
null
8.6
null
null
ICSA-19-183-02
Quest KACE Systems Management Appliance
The vulnerability allows unintentional access to the appliance leveraging functions of the troubleshooting tools located in the administrator user interface. CVE-2019-10973 has been assigned to this vulnerability. A CVSS v3 base score of 2.7 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N).
[]
null
null
2.7
null
ICSA-20-324-03
Real Time Automation EtherNet/IP
The affected product is vulnerable to a stack-based buffer overflow, which may allow an attacker to send a specially crafted packet that may result in a denial-of-service condition or code execution.CVE-2020-25159 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).
[]
null
null
9.8
null
ICSA-20-182-01
Delta Industrial Automation DOPSoft (Update A)
Multiple out-of-bounds read vulnerabilities may be exploited by processing specially crafted project files, which may allow an attacker to read information and/or crash the application.CVE-2020-10597 has been assigned to this vulnerability. A CVSS v3 base score of 4.4 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:L). Opening a specially crafted project file may overflow the heap, which may allow remote code execution, disclosure/modification of information, or cause the application to crash.CVE-2020-14482 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).
[]
null
null
7.8
null
ICSA-22-013-05
Siemens COMOS Web (Update A)
The COMOS Web component of COMOS allows to upload and store arbitrary files at the webserver. This could allow an attacker to store malicious files. The COMOS Web component of COMOS accepts arbitrary code as attachment to tasks. This could allow an attacker to inject malicious code that is executed when loading the attachment. The COMOS Web component of COMOS unpacks specially crafted archive files to relative paths. This vulnerability could allow an attacker to store files in any folder accessible by the COMOS Web webservice. The COMOS Web component of COMOS is vulnerable to SQL injections. This could allow an attacker to execute arbitrary SQL statements. The COMOS Web component of COMOS uses a flawed implementation of CSRF prevention. An attacker could exploit this vulnerability to perform cross-site request forgery attacks.
[]
null
5.4
null
null
ICSA-22-130-04
Eaton Intelligent Power Manager
The affected product is vulnerable to a reflected cross-site scripting vulnerability due to insufficient validation of input from certain resources by the IPM software. An attacker would need access to the local subnet and an administrator interaction to compromise the system.CVE-2021-23282 has been assigned to this vulnerability. A CVSS v3 base score of 5.2 has been calculated; the CVSS vector string is (AV:A/AC:L/PR:H/UI:N/S:U/C:N/I:L/A:H).
[]
null
null
5.2
null
ICSA-23-215-02
Mitsubishi Electric GT and GOT Series Products
Information disclosure vulnerability exists in the Data Transfer Security function on GT Designer3, GOT2000 Series, GOT SIMPLE Series and GT SoftGOT2000. This vulnerability allows an attacker to obtain plaintext passwords by sniffing packets containing encrypted passwords and decrypting the encrypted passwords.
[]
null
null
7.5
null
ICSA-22-258-04
Siemens Mendix SAML Module
Affected versions of the module insufficiently protect from packet capture replay. This could allow unauthorized remote attackers to bypass authentication and get access to the application. For compatibility reasons, fix versions still contain this issue, but only when the not recommended, non default configuration option 'Allow Idp Initiated Authentication' is enabled. CVE-2022-37011 has been assigned to this vulnerability. A CVSS v3 base score of 7.4 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N). Affected versions of the module insufficiently protect from packet capture replay, only when the not recommended, non default configuration option 'Allow Idp Initiated Authentication' is enabled. This CVE entry describes the incomplete fix for CVE-2022-37011 in a specific non default configuration. CVE-2022-44457 has been assigned to this vulnerability. A CVSS v3 base score of 7.4 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N).
[]
null
7.4
null
null
ICSA-22-319-01
Mitsubishi Electric GT SoftGOT2000
A malicious OS command execution vulnerability in OpenSSL affects Mitsubishi Electric GT SoftGOT2000. If an attacker sends a specially crafted certificate, then this vulnerability could allow an attacker to execute malicious OS commands.CVE-2022-2068 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).
[]
null
null
9.8
null
ICSA-18-046-02
GE D60 Line Distance Relay
Multiple stack-based buffer overflow vulnerabilities have been identified, which may allow remote code execution. CVE-2018-5475 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). The SSH functions of the device are vulnerable to buffer overflow conditions that may allow a remote attacker to execute arbitrary code on the device. CVE-2018-5473 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).
[]
null
null
9.8
null
ICSA-23-164-02
Rockwell Automation FactoryTalk Services Platform
Hard-coded cryptographic key vulnerabilities could lead to privilege escalation. FactoryTalk System Services uses a hard-coded cryptographic key to generate administrator cookies. This vulnerability could allow a local authenticated non-admin user to generate an invalid administrator cookie giving them administrative privileges to the FactoryTalk Policy Manger database. The threat actor could make malicious changes to the database to be deployed when a legitimate FactoryTalk Policy Manager user deploys a security policy model. User interaction is required to successfully exploit this vulnerability. Improper authorization in FTSSBackupRestore.exe could lead to the loading of malicious configuration archives. FactoryTalk System Services does not verify that backup configuration archives are password protected. This vulnerability could allow a local authenticated non-admin user to craft a malicious backup archive without password protection to be loaded by FactoryTalk System Services as a valid backup when a restore procedure takes place. This vulnerability requires user interaction for successful exploitation. Origin validation errors could lead to information disclosure. The underlying feedback mechanism of FactoryTalk System Services that transfers the FactoryTalk Policy Manager rules to relevant devices on the network does not verify that the origin of the communication is from a legitimate local client device. This could allow a threat actor to craft a malicious website that, when visited, would send a malicious script to connect to the local WebSocket endpoint and wait for events as if it was a valid client device. If successfully exploited, this could allow a threat actor to receive information, including whether FactoryTalk Policy Manager is installed or the entire security policy. User interaction is required for successful vulnerability exploitation.
[]
null
null
4.1
null
ICSA-19-099-06
Siemens SIMATIC, SIMOCODE, SINAMICS, SITOP, and TIM (Update I)
The webserver of the affected devices contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation which leads to a restart of the webserver of the affected device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the device.
[]
null
7.5
null
null
ICSA-22-111-03
Hitachi Energy MicroSCADA Pro/X SYS600
The Raccoon attack exploits a flaw in the TLS specification that can lead to an attacker being able to compute the pre-master secret in connections which have used a Diffie-Hellman (DH) based ciphersuite. This would result in the attacker being able to eavesdrop on all encrypted communications sent over that TLS connection. The attack can only be exploited if an implementation re-uses a DH secret across multiple TLS connections. Note this vulnerability only impacts DH ciphersuites and not ECDH ciphersuites. This vulnerability affects OpenSSL 1.0.2, which is out of support and no longer receiving public updates. OpenSSL 1.1.1 is not vulnerable to this issue. Fixed in OpenSSL 1.0.2w (Affected 1.0.2-1.0.2v).CVE-2020-1968 has been assigned to this vulnerability. A CVSS v3 base score of 3.7 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N). Node.js versions prior to 10.23.1, 12.20.1, 14.15.4, 15.5.1 allow two copies of a header field in an HTTP request (for example, two transfer-encoding header fields). In this case, Node.js identifies the first header field and ignores the second. This can lead to HTTP request smuggling.CVE-2020-8265 has been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H). Node.js versions prior to 10.23.1, 12.20.1, 14.15.4, 15.5.1 allow two copies of a header field in an HTTP request (for example, two transfer-encoding header fields). In this case, Node.js identifies the first header field and ignores the second. This can lead to HTTP request smuggling.CVE-2020-8287 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N). Node.js < 12.18.4 and < 14.11 can be exploited to perform HTTP desync attacks and deliver malicious payloads to unsuspecting users. The payloads can be crafted by an attacker to hijack user sessions, poison cookies, perform clickjacking, and a multitude of other attacks depending on the architecture of the underlying system. The attack is possible due to a bug in processing of carrier-return symbols in the HTTP header names.CVE-2020-8201 has been assigned to this vulnerability. A CVSS v3 base score of 7.4 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N). The implementation of realpath in libuv < 10.22.1, < 12.18.4, and < 14.9.0 used within Node.js incorrectly determined the buffer size, which can result in a buffer overflow if the resolved path is longer than 256 bytes.CVE-2020-8252 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H). TLS session reuse can lead to host certificate verification bypass in node version < 12.18.0 and < 14.4.0.CVE-2020-8172 has been assigned to this vulnerability. A CVSS v3 base score of 7.4 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N). napi_get_value_string_*() allows various kinds of memory corruption in node < 10.21.0, 12.18.0, and < 14.4.0.CVE-2020-8174 has been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H). A vulnerability was found in postgresql in versions prior to 13.3, 12.7, 11.12, 10.17, and 9.6.22. While modifying certain SQL array values, missing bounds checks let authenticated database users write arbitrary bytes to a wide area of server memory. The highest threat from this vulnerability is to data confidentiality and integrity as well as system availability.CVE-2021-32027 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H). A flaw was found in postgresql. Using an INSERT ... ON CONFLICT ... DO UPDATE command on a purpose-crafted table, an authenticated database user could read arbitrary bytes of server memory. The highest threat from this vulnerability is to data confidentiality.CVE-2021-32028 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N).
[]
null
null
6.5
null
ICSA-24-226-09
Rockwell Automation ControlLogix, GuardLogix 5580, CompactLogix, Compact GuardLogix 5380
A denial-of-service vulnerability exists in the affected products. This vulnerability occurs when a malformed PCCC message is received, causing a fault in the controller.
[]
null
7.5
null
null
ICSA-24-228-08
Siemens COMOS
An issue was discovered in Open Design Alliance Drawings SDK before 2024.12. A corrupted value of number of sectors used by the Fat structure in a crafted DGN file leads to an out-of-bounds write. An attacker can leverage this vulnerability to execute code in the context of the current process. Open Design Alliance Drawings SDK (versions before 2024.1) contains a use-after-free vulnerability that could be triggered while parsing specially crafted DWG file. An attacker could leverage this in conjunction with other vulnerabilities to execute arbitrary code. (ZDI-CAN-19162, ZDI-CAN-19432)
[]
null
7.8
null
null
ICSA-22-314-07
Omron NJ/NX-series Machine Automation Controllers
An attacker who can analyze the communication of the affected product and perform capture-replay can find unintended entry points into the affected product and cause a denial-of-service condition or execute a malicious program.CVE-2022-33971 has been assigned to this vulnerability. A CVSS v3 base score of 8.3 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H).
[]
null
null
8.3
null
ICSA-21-012-04
Siemens Solid Edge
Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds write into uninitialized memory. An attacker could leverage this vulnerability to execute code in the context of the current process. Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in a out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. Affected applications lack proper validation of user-supplied data when parsing PAR files. This can result in an out of bounds write past the memory location that is a read only image address. An attacker could leverage this vulnerability to execute code in the context of the current process. Affected applications lack proper validation of user-supplied data when parsing PAR files. This could lead to a stack based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of the current process. Affected applications lack proper validation of user-supplied data when parsing DFT files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. Affected applications lack proper validation of user-supplied data when parsing of PAR files. This could result in a stack based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of the current process.
[]
null
7.8
null
null
ICSA-21-103-13
Siemens SIMOTICS CONNECT 400 (Update A)
The DNS domain name label parsing functionality does not properly validate the null-terminated name in DNS-responses. The parsing of malformed responses could result in a read past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to cause a denial-of-service condition or leak the read memory. The DNS response parsing functionality does not properly validate various length and counts of the records. The parsing of malformed responses could result in a read past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to cause a denial-of-service condition or leak the memory past the allocated structure. The DNS domain name record decompression functionality does not properly validate the pointer offset values. The parsing of malformed responses could result in a read access past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to cause a denial-of-service condition. The DNS client does not properly randomize DNS transaction IDs. That could allow an attacker to poison the DNS cache or spoof DNS resolving.
[]
null
5.3
null
null
ICSA-22-132-11
Siemens SIMATIC CP 44x-1 RNA
The affected devices improperly handles excessive ARP broadcast requests. This could allow an attacker to create a denial of service condition by performing ARP storming attacks, which can cause the device to reboot.
[]
null
7.4
null
null
ICSA-21-152-01
Siemens SIMATIC S7-1200 and S7-1500 CPU Families (Update A)
Affected devices are vulnerable to a memory protection bypass through a specific operation. A remote unauthenticated attacker with network access to port 102/tcp could potentially write arbitrary data and code to protected memory areas or read sensitive data to launch further attacks.
[]
null
8.1
null
null
ICSMA-21-322-02
Philips Patient Information Center iX (PIC iX) and Efficia CM Series
Patient Information Center iX (PIC iX) Versions C.02 and C.03 receives input or data, but does not validate or incorrectly validates that the input has the properties required to process the data safely and correctly. CVE-2021-43548 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been calculated; the CVSS vector string is (AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H). The use of a hard-coded cryptographic key significantly increases the possibility encrypted data may be recovered from the Patient Information Center iX (PIC iX) Versions B.02, C.02, and C.03. CVE-2021-43552 has been assigned to this vulnerability. A CVSS v3 base score of 6.1 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:N). The use of a broken or risky cryptographic algorithm is an unnecessary risk that may result in the exposure of sensitive information, which affects the communications between Patient Information Center iX (PIC iX) Versions C.02 and C.03 and Efficia CM Series Revisions A.01 to C.0x and 4.0. CVE-2021-43550 has been assigned to this vulnerability. A CVSS v3 base score of 5.9 has been calculated; the CVSS vector string is (AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:L/A:N).
[]
null
null
5.9
null
ICSA-21-315-08
Siemens NX OBJ Translator
The affected application contains a use-after-free vulnerability while parsing OBJ files. An attacker could leverage this vulnerability to execute code in the context of the current process (ZDI-CAN-13771). The affected application is vulnerable to information disclosure by unexpected access to an uninitialized pointer while parsing user-supplied OBJ files. An attacker could leverage this vulnerability to leak information from unexpected memory locations (ZDI-CAN-13770).
[]
null
3.3
null
null
ICSA-22-356-02
Rockwell Automation Studio 5000 Logix Emulate
Studio 5000 Logix Emulate v.20-33 users are granted elevated permissions on certain product services. Due to this misconfiguration, a malicious user could potentially achieve remote code execution on the targeted software.CVE-2022-3156 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been assigned; the CVSS vector string is (AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).
[]
null
null
7.8
null
ICSA-21-348-01
Advantech R-SeeNet
Advantech is aware of multiple SQL injection vulnerabilities in the following pages: group_list, company_list, user_list, and device_list. An attacker could send a specially crafted HTTP request to trigger the vulnerabilities.CVE-2021-21915, CVE-2021-21916, CVE-2021-21917, CVE-2021-21918, CVE-2021-21919, CVE-2021-21920, CVE-2021-21921, CVE-2021-21922, CVE-2021-21923, CVE-2021-21924, CVE-2021-21925, CVE-2021-21926, CVE-2021-21927, CVE-2021-21928, CVE-2021-21929, CVE-2021-21930, CVE-2021-21931, CVE-2021-21932, CVE-2021-21933, CVE-2021-21934, CVE-2021-21935, CVE-2021-21936, and CVE-2021-21937 have been assigned to these vulnerabilities. A CVSS v3 base score of 7.7 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:N/A:N). Advantech is aware of multiple privilege escalation vulnerabilities that could be triggered when an authenticated user replaces a specially crafted file in the system to escalate privileges to NT SYSTEM authority.CVE-2021-21910, CVE-2021-21911, and CVE-2021-21912 have been assigned to these vulnerabilities. A CVSS v3 base score of 8.8 has been assigned; the CVSS vector string is (AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H).
[]
null
null
8.8
null
ICSA-22-102-02
Mitsubishi Electric MELSEC-Q Series C Controller Module
The affected product uses a vulnerable version of Wind River VxWorks that could result in a heap-based buffer overflow in the DHCP clientCVE-2021-29998 has been assigned to this vulnerability. A CVSS v3 base score of 9.0 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H).
[]
null
null
9
null
ICSA-21-257-23
Siemens SIMATIC and TIM
Due to an incorrect authorization check in the affected component, an attacker could extract information about access protected PLC program variables over port 102/tcp from an affected device when reading multiple attributes at once.
[]
null
5.3
null
null
ICSA-21-070-01
Schneider Electric IGSS SCADA Software
This vulnerability could result in loss of data or remote code execution when a malicious CGF (configuration group file) file is imported into an IGSS Definition.CVE-2021-22709 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). This vulnerability could result in loss of data or remote code execution when a malicious CGF file is imported into an IGSS Definition.CVE-2021-22710 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). This vulnerability could result in arbitrary read or write conditions due to missing validation of input data when a malicious CGF file is imported into an IGSS Definition.CVE-2021-22711 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). This vulnerability could result in arbitrary read or write conditions due to an unchecked pointer address when a malicious CGF file is imported into an IGSS Definition.CVE-2021-22712 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).
[]
null
null
7.8
null
ICSA-21-021-03
Honeywell OPC UA Tunneller
The affected product is vulnerable to a heap-based buffer overflow, which may allow an attacker to manipulate memory with controlled values and remotely execute code.CVE-2020-27297 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). The affected product is vulnerable to an out-of-bounds read, which may allow an attacker to obtain and disclose sensitive data information or cause the device to crash.CVE-2020-27299 has been assigned to this vulnerability. A CVSS v3 base score of 8.2 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:N). Some parsing functions in the affected product do not check the return value of malloc and the thread handling the message is forced to close, which may lead to a denial-of-service condition.CVE-2020-27274 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H). The affected product has uncontrolled resource consumption issues, which may allow an attacker to cause a denial-of-service condition.CVE-2020-27295 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).
[]
null
null
7.5
null
ICSA-19-085-01
Siemens SCALANCE X (Update D)
The monitor barrier of the affected products insufficiently blocks data from being forwarded over the mirror port and into the mirrored network. An attacker could exploit this vulnerability to transmit malicious packets to systems in the mirrored network to influence their configuration and runtime behavior. This vulnerability could be exploited by an attacker with network access to the traffic-receiving network. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise the confidentiality and availability of the traffic-generating network. CVE-2019-6569 has been assigned to this vulnerability. A CVSS v3 base score of 5.4 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:C/C:L/I:N/A:L).
[]
null
5.4
null
null
ICSA-19-344-02
Siemens and PKE SiNVR, SiVMS Video Server (Update A)
The HTTP service (default specific port) of the SiNVR 3 Video Server contains an authentication bypass vulnerability, even when properly configured with enforced authentication. CVE-2019-13947, CVE-2019-18337, CVE-2019-18338, CVE-2019-18341, and CVE-2019-18342 have been moved to SSA-761844 and ICSA-21-103-10.CVE-2019-18339 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). Both the SiNVR 3 Video Server and the CCS store user and device passwords by applying weak cryptography. CVE-2019-18340 has been assigned to this vulnerability. A CVSS v3 base score of 5.5 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N).. --------- End Update A Part 4 of 6 ---------CVE-2019-18340 has been assigned to this vulnerability. A CVSS v3 base score of 5.5 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N).
[]
null
null
5.5
null
ICSMA-20-170-04
Baxter Sigma Spectrum Infusion Pumps (Update B)
Sigma Spectrum Infusion System Version(s) 6.x (model 35700BAX) and Baxter Spectrum Infusion System Version(s) 8.x (model 35700BAX2) contain hard-coded passwords which, when physically entered on the keypad, provide access to biomedical menus that include device settings, view of calibration values, and network configuration of the Sigma Spectrum Wireless Battery Module (WBM) if installed. CVE-2020-12039 has been assigned to this vulnerability. A CVSS v3 base score of 4.3 has been calculated; the CVSS vector string is (AV:P/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L). Sigma Spectrum Infusion System Version(s) 6.x (model 35700BAX) and Baxter Spectrum Infusion System Version(s) 8.x (model 35700BAX2) at the application layer uses an unauthenticated clear-text communication channel to send and receive system status and operational data. This could allow an attacker that has circumvented network security measures to view sensitive non-private data or to perform a man-in-the-middle attack. CVE-2020-12040 has been assigned to this vulnerability. A CVSS v3 base score of 7.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L). The Baxter Spectrum WBM (v9, v11, v13, v14, v15, v16, v16D38, v17, v17D19, v20D29 to v20D32, and v22D19 to v22D28) operates a Telnet service with hard-coded credentials when connected to specific SSIDs. CVE-2020-12045 has been assigned to this vulnerability. A CVSS v3 base score of 8.6 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:H). The Baxter Spectrum WBM (v9, v11, v13, v14, v15, v16, v16D38, v17, v17D19, v20D29 to v20D32, and v22D19 to v22D28) Telnet Command-Line Interface grants access to sensitive data stored on the WBM that permits temporary configuration changes to network settings of the WBM. This access allows the WBM to be rebooted. Temporary configuration changes to network settings are removed upon reboot. CVE-2020-12041 has been assigned to this vulnerability. A CVSS v3 base score of 8.6 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:H). The factor-default wireless configuration of the Baxter Spectrum WBM (v17, v17D19, v20D29 to v20D32, and v22D19 to v22D28) enables File Transfer Protocol (FTP) service with hard-coded credentials. CVE-2020-12047 has been assigned to this vulnerability. A CVSS v3 base score of 7.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L). When configured for wireless networking, the Baxter Spectrum WBM (v17, v17D19, v20D29 to v20D32, and v22D19 to v22D28) enables FTP service operating on the WBM to remain operational until the WBM is rebooted. CVE-2020-12043 has been assigned to this vulnerability. A CVSS v3 base score of 7.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L).
[]
null
null
7.3
null
ICSA-22-041-06
Siemens Spectrum Power 4
The integrated web application "Online Help" in affected product contains a Cross-Site Scripting (XSS) vulnerability that could be exploited if unsuspecting users are tricked into accessing a malicious link.
[]
null
5.4
null
null
ICSA-21-194-02
Schneider Electric Modicon Controllers and Software (Update A)
An insufficiently protected credentials vulnerability exists that could cause protected derived function blocks to be read or modified by unauthorized users when accessing a project file. CVE-2021-22778 has been assigned to this vulnerability. A CVSS v3 base score of 8.6 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H).. --------- Begin Update A Part 2 of 2 --------CVE-2021-22778 has been assigned to this vulnerability. A CVSS v3 base score of 8.6 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H). An authentication bypass by spoofing vulnerability exists that could cause unauthorized access in read and write mode to the controller by spoofing the Modbus communication between the engineering software and the controller. CVE-2021-22779 has been assigned to this vulnerability. A CVSS v3 base score of 9.8has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).. --------- End Update A Part 2 of 2 --------CVE-2021-22779 has been assigned to this vulnerability. A CVSS v3 base score of 9.8has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). M&M Software fdtCONTAINER component in versions below 3.5.20304.x and between 3.6 and 3.6.20304.x is vulnerable to deserialization of untrusted data in its project storage. Note: This vulnerability could cause local code execution on the engineering workstation when a malicious project file is loaded into the engineering software.CVE-2020-12525 has been assigned to this vulnerability. A CVSS v3 base score of 7.3 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H). An insufficiently protected credentials vulnerability exists that could cause unauthorized access to a project file protected by a password when this file is shared with untrusted sources. An attacker may bypass the password protection and be able to view and modify a project file.CVE-2021-22780 has been assigned to this vulnerability. A CVSS v3 base score of 7.1 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N). An insufficiently protected credentials vulnerability exists that could cause a leak of SMTP credentials used for mailbox authentication when an attacker can access a project file.CVE-2021-22781 has been assigned to this vulnerability. A CVSS v3 base score of 6.2 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N). A missing encryption of sensitive data vulnerability exists that could cause an information leak allowing disclosure of network and process information, credentials, or intellectual property when an attacker can access a project file.CVE-2021-22782 has been assigned to this vulnerability. A CVSS v3 base score of 6.2 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N).
[]
null
null
6.2
null
ICSA-19-318-05
ABB Power Generation Information Manager (PGIM) and Plant Connect
The affected product is vulnerable to authentication bypass, which may allow an attacker to remotely bypass authentication and extract credentials from the affected device.CVE-2019-18250 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).
[]
null
null
9.8
null
ICSA-17-285-03
Envitech Ltd. EnviDAS Ultimate
The web application lacks proper authentication which could allow an attacker to view information and modify settings or execute code remotely.CVE-2017-9625 has been assigned to this vulnerability. A CVSS v3 base score of 8.2 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:N).
[]
null
null
8.2
null
ICSA-20-177-03
Rockwell Automation FactoryTalk View SE
Due to usernames/passwords being stored in plaintext in Random Access Memory (RAM), a local, authenticated attacker could gain access to certain credentials, including Windows Logon credentials.CVE-2020-14480 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been assigned; the CVSS vector string is (AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H). The DeskLock tool provided with FactoryTalk View SE uses a weak encryption algorithm that may allow a local, authenticated attacker to decipher user credentials, including the Windows user or Windows DeskLock passwords. If the compromised user has an administrative account, an attacker could gain full access to the user 's operating system and certain components of FactoryTalk View SE.CVE-2020-14481 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been assigned; the CVSS vector string is (AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H).
[]
null
null
8.8
null
ICSA-22-069-03
Siemens SINEC NMS
A privileged authenticated attacker could execute arbitrary commands in the local database by sending specially crafted requests to the webserver of the affected application. The affected system allows to upload JSON objects that are deserialized to Java objects. Due to insecure deserialization of user-supplied content by the affected software, a privileged attacker could exploit this vulnerability by sending a maliciously crafted serialized Java object. This could allow the attacker to execute arbitrary code on the device with root privileges. The affected software do not properly check privileges between users during the same web browser session, creating an unintended sphere of control. This could allow an authenticated low privileged user to achieve privilege escalation.
[]
null
7.3
null
null
ICSA-21-224-02
Horner Automation Cscape
The affected application lacks proper validation of user-supplied data when parsing project files. This could lead to an out-of-bounds write. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-32995 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). The affected application lacks proper validation of user-supplied data when parsing project files. This could lead to an out-of-bounds write via an uninitialized pointer. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-33015 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). The affected application lacks proper validation of user-supplied data when parsing project files. This could lead to an out-of-bounds read. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-32975 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).
[]
null
null
7.8
null
ICSMA-20-023-01
GE CARESCAPE, ApexPro, and Clinical Information Center systems
A vulnerability exists in the affected products that could allow an attacker to obtain access to the SSH private key in configuration files.CVE-2020-6961 has been assigned to this vulnerability. A CVSS v3 base score of 10 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H). To see how this vulnerability affects each unique configuration, please apply the environmental portion of CVSS v3.0 score. An input validation vulnerability exists in the web-based system configuration utility that could allow an attacker to obtain arbitrary remote code execution.CVE-2020-6962 has been assigned to this vulnerability. A CVSS v3 base score of 10 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H). To see how this vulnerability affects each unique configuration, please apply the environmental portion of CVSS v3.0 score The affected products utilized hard coded SMB credentials, which may allow an attacker to remotely execute arbitrary code.CVE-2020-6963 has been assigned to this vulnerability. A CVSS v3 base score of 10 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H). To see how this vulnerability affects each unique configuration, please apply the environmental portion of CVSS v3.0 score The integrated service for keyboard switching of the affected devices could allow attackers to obtain remote keyboard input access without authentication over the network.CVE-2020-6964 has been assigned to this vulnerability. A CVSS v3 base score of 10 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H). To see how this vulnerability affects each unique configuration, please apply the environmental portion of CVSS v3.0 score A vulnerability in the software update mechanism allows an authenticated attacker to upload arbitrary files on the system through a crafted update package.CVE-2020-6965 has been assigned to this vulnerability. A CVSS v3 base score of 8.5 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H). To see how this vulnerability affects each unique configuration, please apply the environmental portion of CVSS v3.0 score The affected products utilize a weak encryption scheme for remote desktop control, which may allow an attacker to obtain remote code execution of devices on the network.CVE-2020-6966 has been assigned to this vulnerability. A CVSS v3 base score of 10 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H). To see how this vulnerability affects each unique configuration, please apply the environmental portion of CVSS v3.0 score
[]
null
null
10
null
ICSA-24-228-04
Siemens SINEC Traffic Analyzer
The affected application mounts the container's root filesystem with read and write privileges. This could allow an attacker to alter the container's filesystem leading to unauthorized modifications and data corruption. The affected application do not properly enforce restriction of excessive authentication attempts. This could allow an unauthenticated attacker to conduct brute force attacks against legitimate user credentials or keys. The affected application do not have access control for accessing the files. This could allow an authenticated attacker with low privilege's to get access to sensitive information. The affected application does not properly handle cacheable HTTP responses in the web service. This could allow an attacker to read and modify data stored in the local cache. The affected application is missing general HTTP security headers in the web server. This could allow an attacker to make the servers more prone to clickjacking attack.
[]
null
4.2
null
null
ICSA-19-178-01
ABB PB610 Panel Builder 600
The ABB CP635 HMI component implements hidden administrative accounts used during the provisioning phase of the HMI interface. These credentials allow the provisioning tool Panel Builder 600 to flash a new interface and Tags (MODBUS coils) mapping to the HMI. These credentials are used over both HTTP(S) and FTP. There is no option to disable or change these undocumented credentials.CVE-2019-7225 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is (AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). The IDAL HTTP server CGI interface contains a URL, which allows an unauthenticated attacker to bypass authentication and gain access to privileged functions.CVE-2019-7226 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is (AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). The IDAL FTP server fails to ensure directory change requests do not change to locations outside of the root FTP directory. An authenticated attacker can simply traverse outside the server root directory by changing the directory.CVE-2019-7227 has been assigned to this vulnerability. A CVSS v3 base score of 7.3 has been calculated; the CVSS vector string is (AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N). The IDAL HTTP server is vulnerable to memory corruption through insecure use of user supplied format strings. An attacker can abuse this functionality to bypass authentication or execute code on the server.CVE-2019-7228 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is (AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). The IDAL FTP server is vulnerable to memory corruption through insecure use of user supplied format strings. An attacker can abuse this functionality to bypass authentication or execute code on the server.CVE-2019-7230 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is (AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). The IDAL HTTP server is vulnerable to a stack-based buffer overflow when a large host header is sent in a HTTP request. The host header value overflows a buffer and can overwrite the Structured Exception Handler (SEH) address with a large chunk of data.CVE-2019-7232 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is (AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). The IDAL FTP server is vulnerable to a buffer overflow when a large string is sent by an authenticated attacker. This overflow is handled, but terminates the process.CVE-2019-7231 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been calculated; the CVSS vector string is (AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).
[]
null
null
6.5
null
ICSA-23-199-06
GE Digital CIMPLICITY
All versions of GE Digital CIMPLICITY that are not adhering to SDG guidance and accepting documents from untrusted sources are vulnerable to memory corruption issues due to insufficient input validation, including issues such as out-of-bounds reads and writes, use-after-free, stack-based buffer overflows, uninitialized pointers, and a heap-based buffer overflow. Successful exploitation could allow an attacker to execute arbitrary code.
[]
null
null
6.6
null
ICSA-22-195-12
Siemens SRCS VPN Feature in SIMATIC CP Devices
The application lacks proper validation of user-supplied data when parsing specific messages. This could result in a heap-based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of device. The application does not correctly escape some user provided fields during the authentication process. This could allow an attacker to inject custom commands and execute arbitrary code with elevated privileges. By injecting code to specific configuration options for OpenVPN, an attacker could execute arbitrary code with elevated privileges.
[]
null
7.6
null
null
ICSA-18-249-01
Ice Qube Thermal Management Center
The web application does not properly authenticate users, which may allow an attacker to gain access to sensitive information.CVE-2017-14026 has been assigned to this vulnerability. A CVSS v3 base score of 8.6 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:L). Passwords are stored in plaintext in a file that is accessible without authentication.CVE-2017-16714 has been assigned to this vulnerability. A CVSS v3 base score of 8.6 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:L).
[]
null
null
8.6
null
ICSA-20-310-02
Mitsubishi Electric GT14 Model of GOT1000 Series
The affected product has a memory corruption vulnerability, which may allow an attacker to send a specially crafted packet that may result in a denial-of-service condition or code execution.CVE-2020-5644 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). The affected product has a session fixation vulnerability, which may allow an attacker to send a specially crafted packet that may result in a denial-of-service condition.CVE-2020-5645 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H). The affected product has a NULL pointer dereference vulnerability, which may allow an attacker to send a specially crafted packet that may result in a denial-of-service condition.CVE-2020-5646 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H). The affected product has an access control issue, which may allow an attacker to send a specially crafted packet that may result in a denial-of-service condition or code execution.CVE-2020-5647 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). The affected product is vulnerable to an argument injection, which may allow an attacker to send a specially crafted packet that may result in a denial-of-service condition or code execution.CVE-2020-5648 has been assigned to this vulnerability. A CVSS v3 base score of 7.1 has been calculated; the CVSS vector string is (AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:H). The affected product has a resource management issue, which may allow an attacker to send a specially crafted packet that may result in a denial-of-service condition.CVE-2020-5649 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L).
[]
null
null
5.3
null
ICSA-19-043-04
Siemens SIMATIC S7-300 CPU
The affected CPUs improperly validate S7 communication packets which could cause a Denial-of-Service condition of the CPU. The CPU will remain in DEFECT mode until manual restart. Successful exploitation requires an attacker to be able to send a specially crafted S7 communication packet to a communication interface of the CPU. This includes Ethernet, PROFIBUS, and Multi Point Interfaces (MPI). No user interaction or privileges are required to exploit the security vulnerability. The vulnerability could allow causing a Denial-of-Service condition of the core functionality of the CPU, compromising the availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known. Siemens confirms the security vulnerability and provides mitigations to resolve the security issue.
[]
null
7.5
null
null
ICSA-22-034-02
Airspan Networks Mimosa
The affected product does not perform proper authorization and authentication checks on multiple API routes. An attacker may gain access to these API routes and achieve remote code execution, create a denial-of-service condition, and obtain sensitive information.CVE-2022-21196 has been assigned to this vulnerability. A CVSS v3 base score of 10.0 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H). The affected product does not perform proper authorization checks on multiple API functions. An attacker may gain access to these functions and achieve remote code execution, create a denial-of-service condition, and obtain sensitive information.CVE-2022-21141 has been assigned to this vulnerability. A CVSS v3 base score of 10.0 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H). This vulnerability could allow an attacker to force the server to create and execute a web request granting access to backend APIs that are only accessible to the Mimosa MMP server, or request pages that could perform some actions themselves. The attacker could force the server into accessing routes on those cloud-hosting platforms, accessing secret keys, changing configurations, etc.CVE-2022-21215 has been assigned to this vulnerability. A CVSS v3 base score of 10.0 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H). The affected product does not properly sanitize user input, which may allow an attacker to perform a SQL injection and obtain sensitive information.CVE-2022-21176 has been assigned to this vulnerability. A CVSS v3 base score of 8.6 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N). The affected product has a deserialization function that does not validate or check the data, allowing arbitrary classes to be created.CVE-2022-0138 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N). The affected product does not properly sanitize user input on several locations, which may allow an attacker to inject arbitrary commands.CVE-2022-21143 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). The affected product uses the MD5 algorithm to hash the passwords before storing them but does not salt the hash. As a result, attackers may be able to crack the hashed passwords.CVE-2022-21800 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N).
[]
null
null
6.5
null
ICSA-22-006-02
Fernhill SCADA
A specially crafted packet sent to the Fernhill SCADA Server may cause an exception, causing the server process (FHSvrService.exe) to exit.CVE-2022-21155 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).
[]
null
null
7.5
null
ICSA-21-280-01
Johnson Controls exacqVision Server Bundle
The software does not properly assign, modify, track, or check privileges. This could allow unauthenticated users access to credentials stored in the exacqVision Server.CVE-2021-27664 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).
[]
null
null
9.8
null
ICSA-18-081-02
Beckhoff TwinCAT
Several kernel drivers lack proper validation of user-supplied pointer values. An attacker who is able to execute code on the target may be able to exploit this vulnerability to obtain SYSTEM privileges. CVE-2018-7502 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).
[]
null
null
7.8
null
ICSA-23-047-05
Siemens SiPass integrated AC5102 / ACC-G2 and ACC-AP
Affected devices improperly sanitize user input on the telnet command line interface. This could allow an authenticated user to escalate privileges by injecting arbitrary commands that are executed with root privileges.
[]
null
7.8
null
null
ICSA-23-257-01
Siemens SIMATIC, SIPLUS Products
The ANSI C OPC UA SDK contains an integer overflow vulnerability that could cause the application to run into an infinite loop during certificate validation. This could allow an unauthenticated remote attacker to create a denial of service condition by sending a specially crafted certificate.
[]
null
7.5
null
null
ICSA-20-042-11
Siemens SIMATIC S7-1500 (Update A)
Affected devices contain a vulnerability that allows an unauthenticated attacker to trigger a Denial-of-Service condition. The vulnerability can be triggered if specially crafted UDP packets are sent to the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise the device availability.
[]
null
7.5
null
null
ICSA-17-285-03
Envitech Ltd. EnviDAS Ultimate
The web application lacks proper authentication which could allow an attacker to view information and modify settings or execute code remotely.CVE-2017-9625 has been assigned to this vulnerability. A CVSS v3 base score of 8.2 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:N).
[]
null
null
8.2
null
ICSA-21-194-06
Siemens SIMATIC Software Products (Update B)
A directory containing metafiles relevant to devices' configurations has write permissions. An attacker could leverage this vulnerability by changing the content of certain metafiles and subsequently manipulate parameters or behavior of devices that would be later configured by the affected software.
[]
null
7.3
null
null
ICSA-18-228-01
Emerson DeltaV DCS Workstations
A specially crafted DLL file may be placed in the search path and loaded as an internal and valid DLL, which may allow arbitrary code execution.CVE-2018-14797 has been assigned to this vulnerability. A CVSS v3 base score of 8.2 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:H). Improper path validation may allow an attacker to replace executable files.CVE-2018-14795 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H). Non-administrative users are able to change executable and library files on the affected products.CVE-2018-14791 has been assigned to this vulnerability. A CVSS v3 base score of 8.2 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:H). An open communication port could be exploited to allow arbitrary code execution.CVE-2018-14793 has been assigned to this vulnerability. A CVSS v3 base score of 9.6 has been calculated; the CVSS vector string is (AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H).
[]
null
null
9.6
null
ICSA-23-304-03
Zavio IP Camera
Zavio IP Cameras CF7500, CF7300, CF7201, CF7501, CB3211, CB3212, CB5220, CB6231, B8520, B8220, CD321 with firmware version M2.1.6.05 are vulnerable to multiple instances of stack-based overflows. While processing XML elements from incoming network requests, the product does not sufficiently check or validate allocated buffer size. This may lead to remote code execution. Zavio IP Cameras CF7500, CF7300, CF7201, CF7501, CB3211, CB3212, CB5220, CB6231, B8520, B8220, CD321 with firmware version M2.1.6.05 are vulnerable to multiple instances of stack-based overflows. While parsing certain XML elements from incoming network requests, the product does not sufficiently check or validate allocated buffer size. This may lead to remote code execution. Zavio IP Cameras CF7500, CF7300, CF7201, CF7501, CB3211, CB3212, CB5220, CB6231, B8520, B8220, CD321 with firmware version M2.1.6.05 are vulnerable to multiple instances of stack-based overflows. During the processing and parsing of certain fields in XML elements from incoming network requests, the product does not sufficiently check or validate allocated buffer size. This may lead to remote code execution. Zavio IP Cameras CF7500, CF7300, CF7201, CF7501, CB3211, CB3212, CB5220, CB6231, B8520, B8220, CD321 with firmware version M2.1.6.05 are vulnerable to stack-based overflows. During the process of updating certain settings sent from incoming network requests, the product does not sufficiently check or validate allocated buffer size. This may lead to remote code execution. Zavio IP Cameras CF7500, CF7300, CF7201, CF7501, CB3211, CB3212, CB5220, CB6231, B8520, B8220, CD321 with firmware version M2.1.6.05 has a command injection vulnerability in their implementation of their binaries and handling of network requests.
[]
null
null
8.8
null
ICSA-22-179-03
Advantech iView
The affected product is vulnerable to multiple SQL injections, which may allow an unauthorized attacker to disclose information.CVE-2022-2135 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N). The affected product is vulnerable to multiple SQL injections that require low privileges for exploitation and may allow an unauthorized attacker to disclose information.CVE-2022-2136 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H). The affected product is vulnerable to two SQL injections that require high privileges for exploitation and may allow an unauthorized attacker to disclose information.CVE-2022-2137 has been assigned to this vulnerability. A CVSS v3 base score of 4.9 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N). The affected product is vulnerable to a SQL injection with high attack complexity, which may allow an unauthorized attacker to disclose information.CVE-2022-2142 has been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H). The affected product is vulnerable due to missing authentication, which may allow an attacker to read or modify sensitive data and execute arbitrary code, resulting in a denial-of-service condition.CVE-2022-2138 has been assigned to this vulnerability. A CVSS v3 base score of 8.2 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:H). The affected product is vulnerable to directory traversal, which may allow an attacker to access unauthorized files and execute arbitrary code.CVE-2022-2139 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N). The affected product is vulnerable to two instances of command injection, which may allow an attacker to remotely execute arbitrary code.CVE-2022-2143 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).
[]
null
null
9.8
null
ICSA-20-170-05
Rockwell Automation FactoryTalk View SE
The affected product does not properly validate input of filenames within a project directory. A remote, unauthenticated attacker may be able to execute a crafted file on a remote endpoint that may result in remote code execution (RCE).CVE-2020-12029 has been assigned to this vulnerability. A CVSS v3 base score of 9.0 has been assigned; the CVSS vector string is (AV:L/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:N). After bypassing memory corruption mechanisms found in the operating system, a local, authenticated attacker may corrupt the associated memory space allowing for arbitrary code execution.CVE-2020-12031 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (AV:L/AC:H/PR:L/UI:R/S:C/C:H/I:H/A:H). A remote, authenticated attacker may be able to utilize certain handlers to interact with the data on the remote endpoint since those handlers do not enforce appropriate permissions.CVE-2020-12028 has been assigned to this vulnerability. A CVSS v3 base score of 7.3 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:N). The affected product discloses the hostnames and file paths for certain files within the system. A remote, authenticated attacker may be able to leverage this information for reconnaissance efforts.CVE-2020-12027 has been assigned to this vulnerability. A CVSS v3 base score of 4.3 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N).
[]
null
null
4.3
null
ICSA-23-108-02
Schneider Electric Easy UPS Online Monitoring Software
A vulnerability exists that could allow changes to administrative credentials, leading to potential remote code execution without requiring prior authentication on the Java RMI interface. CVE-2023-29411 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). A vulnerability exists that could cause remote code execution when manipulating internal methods through Java RMI interface. CVE-2023-29412 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). A vulnerability exists that could cause a denial-of-service condition when accessed by an unauthenticated user on the Schneider UPS Monitor service. CVE-2023-29413 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).
[]
null
7.5
null
null
ICSA-19-248-01
Red Lion Controls Crimson
Multiple vulnerabilities can be exploited when a valid user opens a specially crafted, malicious input file that can reference memory after it has been freed.CVE-2019-10996 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). Multiple vulnerabilities can be exploited when a valid user opens a specially crafted, malicious input file that operates outside of the designated memory area.CVE-2019-10978 has been assigned to this vulnerability. A CVSS v3 base score of 3.3 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N). Multiple vulnerabilities can be exploited when a valid user opens a specially crafted, malicious input file that causes the program to mishandle pointers.CVE-2019-10984 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). Crimson uses a hard-coded password to encrypt protected files in transit and at rest, which may allow an attacker to access configuration files.CVE-2019-10990 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N).
[]
null
null
6.5
null
ICSMA-17-250-02A
Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump Vulnerabilities (Update A)
A third-party component used in the pump does not verify input buffer size prior to copying, leading to a buffer overflow, allowing remote code execution on the target device. The pump receives the potentially malicious input infrequently and under certain conditions, increasing the difficulty of exploitation. CVE-2017-12718 been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H). A third-party component used in the pump does not verify input buffer size prior to copying, leading to a buffer overflow, allowing remote code execution on the target device. The pump receives the potentially malicious input infrequently and under certain conditions, increasing the difficulty of exploitation. CVE-2017-12718 been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H). A third-party component used in the pump reads memory out of bounds, causing the communications module to crash. Smiths Medical assesses that the crash of the communications module would not impact the operation of the therapeutic module. CVE-2017-12722 been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L). A third-party component used in the pump does not verify input buffer size prior to copying, leading to a buffer overflow, allowing remote code execution on the target device. The pump receives the potentially malicious input infrequently and under certain conditions, increasing the difficulty of exploitation. CVE-2017-12718 been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H). A third-party component used in the pump reads memory out of bounds, causing the communications module to crash. Smiths Medical assesses that the crash of the communications module would not impact the operation of the therapeutic module. CVE-2017-12722 been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L). The pump with default network configuration uses hard-coded credentials to automatically establish a wireless network connection. The pump will establish a wireless network connection even if the pump is Ethernet connected and active; however, if the wireless association is established and the Ethernet cable is attached, the pump does not attach the network stack to the wireless network. In this scenario, all network traffic is instead directed over the wired Ethernet connection. CVE-2017-12725 been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). A third-party component used in the pump does not verify input buffer size prior to copying, leading to a buffer overflow, allowing remote code execution on the target device. The pump receives the potentially malicious input infrequently and under certain conditions, increasing the difficulty of exploitation. CVE-2017-12718 been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H). A third-party component used in the pump reads memory out of bounds, causing the communications module to crash. Smiths Medical assesses that the crash of the communications module would not impact the operation of the therapeutic module. CVE-2017-12722 been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L). The pump with default network configuration uses hard-coded credentials to automatically establish a wireless network connection. The pump will establish a wireless network connection even if the pump is Ethernet connected and active; however, if the wireless association is established and the Ethernet cable is attached, the pump does not attach the network stack to the wireless network. In this scenario, all network traffic is instead directed over the wired Ethernet connection. CVE-2017-12725 been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). The FTP server on the pump does not require authentication if the pump is configured to allow FTP connections. CVE-2017-12720 been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H). A third-party component used in the pump does not verify input buffer size prior to copying, leading to a buffer overflow, allowing remote code execution on the target device. The pump receives the potentially malicious input infrequently and under certain conditions, increasing the difficulty of exploitation. CVE-2017-12718 been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H). A third-party component used in the pump reads memory out of bounds, causing the communications module to crash. Smiths Medical assesses that the crash of the communications module would not impact the operation of the therapeutic module. CVE-2017-12722 been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L). The pump with default network configuration uses hard-coded credentials to automatically establish a wireless network connection. The pump will establish a wireless network connection even if the pump is Ethernet connected and active; however, if the wireless association is established and the Ethernet cable is attached, the pump does not attach the network stack to the wireless network. In this scenario, all network traffic is instead directed over the wired Ethernet connection. CVE-2017-12725 been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). The FTP server on the pump does not require authentication if the pump is configured to allow FTP connections. CVE-2017-12720 been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H). The FTP server on the pump contains hardcoded credentials, which are not fully initialized. The FTP server is only accessible if the pump is configured to allow FTP connections. CVE-2017-12724 been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H). A third-party component used in the pump does not verify input buffer size prior to copying, leading to a buffer overflow, allowing remote code execution on the target device. The pump receives the potentially malicious input infrequently and under certain conditions, increasing the difficulty of exploitation. CVE-2017-12718 been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H). A third-party component used in the pump reads memory out of bounds, causing the communications module to crash. Smiths Medical assesses that the crash of the communications module would not impact the operation of the therapeutic module. CVE-2017-12722 been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L). The pump with default network configuration uses hard-coded credentials to automatically establish a wireless network connection. The pump will establish a wireless network connection even if the pump is Ethernet connected and active; however, if the wireless association is established and the Ethernet cable is attached, the pump does not attach the network stack to the wireless network. In this scenario, all network traffic is instead directed over the wired Ethernet connection. CVE-2017-12725 been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). The FTP server on the pump does not require authentication if the pump is configured to allow FTP connections. CVE-2017-12720 been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H). The FTP server on the pump contains hardcoded credentials, which are not fully initialized. The FTP server is only accessible if the pump is configured to allow FTP connections. CVE-2017-12724 been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H). Telnet on the pump uses hardcoded credentials, which can be used if the pump is configured to allow external communications. Smiths Medical assesses that it is not possible to upload files via Telnet and the impact of this vulnerability is limited to the communications module. CVE-2017-12726 been assigned to this vulnerability. A CVSS v3 base score of 5.6 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:L). A third-party component used in the pump does not verify input buffer size prior to copying, leading to a buffer overflow, allowing remote code execution on the target device. The pump receives the potentially malicious input infrequently and under certain conditions, increasing the difficulty of exploitation. CVE-2017-12718 been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H). A third-party component used in the pump reads memory out of bounds, causing the communications module to crash. Smiths Medical assesses that the crash of the communications module would not impact the operation of the therapeutic module. CVE-2017-12722 been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L). The pump with default network configuration uses hard-coded credentials to automatically establish a wireless network connection. The pump will establish a wireless network connection even if the pump is Ethernet connected and active; however, if the wireless association is established and the Ethernet cable is attached, the pump does not attach the network stack to the wireless network. In this scenario, all network traffic is instead directed over the wired Ethernet connection. CVE-2017-12725 been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). The FTP server on the pump does not require authentication if the pump is configured to allow FTP connections. CVE-2017-12720 been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H). The FTP server on the pump contains hardcoded credentials, which are not fully initialized. The FTP server is only accessible if the pump is configured to allow FTP connections. CVE-2017-12724 been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H). Telnet on the pump uses hardcoded credentials, which can be used if the pump is configured to allow external communications. Smiths Medical assesses that it is not possible to upload files via Telnet and the impact of this vulnerability is limited to the communications module. CVE-2017-12726 been assigned to this vulnerability. A CVSS v3 base score of 5.6 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:L). The pump does not validate host certificate, leaving the pump vulnerable to a man-in-the-middle (MITM) attack. CVE-2017-12721 been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N). A third-party component used in the pump does not verify input buffer size prior to copying, leading to a buffer overflow, allowing remote code execution on the target device. The pump receives the potentially malicious input infrequently and under certain conditions, increasing the difficulty of exploitation. CVE-2017-12718 been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H). A third-party component used in the pump reads memory out of bounds, causing the communications module to crash. Smiths Medical assesses that the crash of the communications module would not impact the operation of the therapeutic module. CVE-2017-12722 been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L). The pump with default network configuration uses hard-coded credentials to automatically establish a wireless network connection. The pump will establish a wireless network connection even if the pump is Ethernet connected and active; however, if the wireless association is established and the Ethernet cable is attached, the pump does not attach the network stack to the wireless network. In this scenario, all network traffic is instead directed over the wired Ethernet connection. CVE-2017-12725 been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). The FTP server on the pump does not require authentication if the pump is configured to allow FTP connections. CVE-2017-12720 been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H). The FTP server on the pump contains hardcoded credentials, which are not fully initialized. The FTP server is only accessible if the pump is configured to allow FTP connections. CVE-2017-12724 been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H). Telnet on the pump uses hardcoded credentials, which can be used if the pump is configured to allow external communications. Smiths Medical assesses that it is not possible to upload files via Telnet and the impact of this vulnerability is limited to the communications module. CVE-2017-12726 been assigned to this vulnerability. A CVSS v3 base score of 5.6 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:L). The pump does not validate host certificate, leaving the pump vulnerable to a man-in-the-middle (MITM) attack. CVE-2017-12721 been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N). The pump stores some passwords in the configuration file, which are accessible if the pump is configured to allow external communications. CVE-2017-12723 been assigned to this vulnerability. A CVSS v3 base score of 3.7 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N).
[]
null
null
3.7
null
ICSA-21-259-02
Schneider Electric EcoStruxure and SCADAPack
When a malicious project file is loaded on the engineering workstation software, it deploys a malicious script to execute arbitrary code in unauthorized locations.CVE-2021-22797has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).
[]
null
null
7.8
null
ICSA-23-047-06
Siemens Simcenter Femap before V2023.1
The affected application contains an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17745) The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17854)
[]
null
7.8
null
null
ICSA-23-264-06
Rockwell Automation FactoryTalk View Machine Edition
FactoryTalk View Machine Edition on the PanelView Plus, improperly verifies user's input, which allows unauthenticated attacker to achieve remote code executed via crafted malicious packets. The device has the functionality, through a CIP class, to execute exported functions from libraries. There is a routine that restricts it to execute specific functions from two dynamic link library files. By using a CIP class, an attacker can upload a self-made library to the device which allows the attacker to bypass the security check and execute any code written in the function.
[]
null
null
9.8
null
ICSA-21-040-07
Siemens SCALANCE W780 and W740
Sending specially crafted packets through the ARP protocol to an affected device could cause a partial denial-of-service, preventing the device to operate normally for a short period of time.
[]
null
4.3
null
null
ICSA-23-103-04
Siemens TIA Portal
Affected products contain a path traversal vulnerability that could allow the creation or overwrite of arbitrary files in the engineering system. If the user is tricked to open a malicious PC system configuration file, an attacker could exploit this vulnerability to achieve arbitrary code execution.
[]
null
7.3
null
null
ICSMA-20-079-01
Insulet Omnipod
The affected insulin pump is designed to communicate using a wireless RF with an Insulet manufactured Personal Diabetes Manager device. This wireless RF communication protocol does not properly implement authentication or authorization. An attacker with access to one of the affected insulin pump models may be able to modify and/or intercept data. This vulnerability could also allow attackers to change pump settings and control insulin delivery.CVE-2020-10627has been assigned to this vulnerability. A CVSS v3 base score of 7.3 has been assigned; the CVSS vector string is (AV:L/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:L).
[]
null
null
7.3
null
ICSA-17-320-02
Siemens SICAM
The integrated web server (Port 80/TCP) of the affected devices could allow unauthenticated remote attackers to obtain sensitive device information over the network.CVE-2017-12737 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N). The integrated web server (Port 80/TCP) of the affected devices could allow cross-site scripting (XSS) attacks if unsuspecting users are tricked into clicking on a malicious link.CVE-2017-12738 has been assigned to this vulnerability. A CVSS v3 base score of 6.1 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N). The integrated web server (Port 80/TCP) of the affected devices could allow unauthenticated remote attackers to execute arbitrary code on the affected device.CVE-2017-12739 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).
[]
null
null
9.8
null
ICSA-21-210-02
Wibu-Systems CodeMeter Runtime
A buffer over-read vulnerability in the CodeMeter Runtime network server could cause the server to return packets containing data from the heap. An unauthenticated remote attacker could exploit this issue to disclose heap memory contents or crash the CodeMeter Runtime Server (i.e., CodeMeter.exe). A buffer over-read vulnerability in the HTTP(S) service of the CodeMeter Runtime CmWAN server could cause the server to crash. An unauthenticated remote attacker with access to the CmWAN port could exploit this issue to crash the CodeMeter Runtime Server (i.e., CodeMeter.exe).
[]
null
7.5
null
null
ICSA-21-131-09
Siemens Mendix Excel Importer Module
Uploading a manipulated XML File results in an exception that could expose information about the Application-Server and the used XML-Framework.
[]
null
4.3
null
null
ICSA-23-103-04
Siemens TIA Portal
Affected products contain a path traversal vulnerability that could allow the creation or overwrite of arbitrary files in the engineering system. If the user is tricked to open a malicious PC system configuration file, an attacker could exploit this vulnerability to achieve arbitrary code execution.
[]
null
7.3
null
null
ICSA-22-104-12
Siemens SIMATIC S7-400
Affected devices improperly handle specially crafted packets sent to port 102/tcp. This could allow an attacker to create a Denial-of-Service condition. A restart is needed to restore normal operations. CVE-2021-40368 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).
[]
null
7.5
null
null
ICSA-20-105-05
Siemens RUGGEDCOM, SCALANCE, SIMATIC, SINEMA (Update B)
Linux kernel versions 4.9+ can be forced to make very expensive calls to tcp_collapse_ofo_queue() and tcp_prune_ofo_queue() for every incoming packet which can lead to a denial of service. The Linux kernel, versions 3.9+, is vulnerable to a denial of service attack with low rates of specially modified packets targeting IP fragment re-assembly. An attacker may cause a denial of service condition by sending specially crafted IP fragments. Various vulnerabilities in IP fragmentation have been discovered and fixed over the years. The current vulnerability (CVE-2018-5391) became exploitable in the Linux kernel with the increase of the IP fragment reassembly queue size.
[]
null
7.5
null
null
ICSA-21-110-04
Delta Electronics CNCSoft ScreenEditor
The affected product is vulnerable to an out-of-bounds read while processing project files, which may allow an attacker to execute arbitrary code.CVE-2021-22668 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).
[]
null
null
7.8
null
ICSA-21-236-02
Hitachi ABB Power Grids Retail Operations and CSB Products
An attacker who has gained access to an authorized user 's computer could exploit this vulnerability to access database credentials and gain read/edit access to application data.CVE-2021-35529 has been assigned to this vulnerability. A CVSS v3 base score of 7.7 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:N).
[]
null
null
7.7
null
ICSA-19-204-02
NREL EnergyPlus
The application fails to prevent an exception handler from being overwritten with arbitrary code.CVE-2019-10974 has been assigned to this vulnerability. A CVSS v3 base score of 6.1 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:L).
[]
null
null
6.1
null
ICSA-19-134-01
Omron Network Configurator for DeviceNet (Update A)
The application searches for resources by means of an untrusted search path that could execute a malicious .dll file not under the application's direct control and outside the intended directories.CVE-2019-10971 has been assigned to this vulnerability. A CVSS v3 base score of 7.3 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H).
[]
null
null
7.3
null
ICSA-24-268-02
Alisonic Sibylla
Alisonic Sibylla devices are vulnerable to SQL injection attacks, which could allow complete access to the database.
[]
null
9.4
null
null
ICSA-21-315-04
Siemens Mendix
Applications built with affected versions of Mendix Studio Pro do not prevent file documents from being cached when files are opened or downloaded using a browser. This could allow a local attacker to read those documents by exploring the browser cache.
[]
null
4
null
null
ICSA-20-035-01
ICSA-20-035-01_AutomationDirect C-More Touch Panels
It is possible to unmask credentials and other sensitive information on unprotected project files, which may allow an attacker to remotely access the system and manipulate system configurations.CVE-2020-6969 has been assigned to this vulnerability. A CVSS v3 base score of 10.0 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H).
[]
null
null
10
null
ICSA-23-313-02
Hitachi Energy eSOMS
The response messages received from the eSOMS report generation using certain parameter queries with full file path can be abused for enumerating the local file system structure. The responses for web queries with certain parameters disclose internal path of resources. This information can be used to learn internal structure of the application and to further plot attacks against web servers and deployed web applications. Poorly constructed webap requests and URI components with special characters trigger unhandled errors and exceptions, disclosing information about the underlying technology and other sensitive information details. The website unintentionally reveals sensitive information including technical details like version Info, endpoints, backend server, Internal IP. etc., which could expose additional attack surface containing other vulnerabilities.
[]
null
5.3
null
null
ICSA-23-320-03
Siemens Desigo CC product family
A buffer over-read vulnerability in the CodeMeter Runtime network server could cause the server to return packets containing data from the heap. An unauthenticated remote attacker could exploit this issue to disclose heap memory contents or crash the CodeMeter Runtime Server (i.e., CodeMeter.exe). A buffer over-read vulnerability in the HTTP(S) service of the CodeMeter Runtime CmWAN server could cause the server to crash. An unauthenticated remote attacker with access to the CmWAN port could exploit this issue to crash the CodeMeter Runtime Server (i.e., CodeMeter.exe). In CodeMeter Runtime versions up to 7.60b, there is a heap buffer overflow vulnerability which can potentially lead to a remote code execution. Currently, no PoC is known to us. To exploit the heap overflow, additional protection mechanisms need to be broken. Remote access is only possible if CodeMeter is configured as a server. If CodeMeter is not configured as a server, the adversary would need to log in to the machine where the CodeMeter Runtime is running or trick the user into sending a malicious request to CodeMeter. This might result in an escalation of privilege. (WIBU-230704-01)
[]
null
9
null
null
ICSA-20-051-03
Honeywell NOTI-FIRE-NET Web Server (NWS-3)
The Honeywell Fire Web Server 's authentication may be bypassed by a capture-replay attack from a web browser.CVE-2020-6972 has been assigned to this vulnerability. A CVSS v3 base score of 9.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:L/A:N). The affected product is vulnerable to a path traversal attack, which allows an attacker to bypass access to restricted directories.CVE-2020-6974 has been assigned to this vulnerability. A CVSS v3 base score of 9.4 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L).
[]
null
null
9.4
null
ICSA-18-128-03
Siemens Siveillance VMS Video Mobile App
Improper certificate validation could allow an attacker in a privileged network position to read data from and write data to the encrypted communication channel between the app and a server. The security vulnerability could be exploited by an attacker in a privileged network position which allows intercepting the communication channel between the affected app and a server (such as Man-in-the-Middle). Furthermore, an attacker must be able to generate a certificate that results for the validation algorithm in a checksum identical to a trusted certificate. Successful exploitation requires no user interaction. The vulnerability could allow reading data from and writing data to the encrypted communication channel between the app and a server, impacting the communication's confidentiality and integrity. At the time of advisory publication no public exploitation of this security vulnerability was known. Siemens confirms the security vulnerability and provides mitigations to resolve the security issue.
[]
null
null
4.8
null
ICSA-18-032-03
Gemalto Sentinel License Manager
Language packs (zip files) with invalid HTML files lead to NULL pointer dereferences, which could be exploited by an attacker leveraging malicious HTML files. This could lead to a denial-of-service condition. CVE-2017-11498 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H). Language packs containing file names longer than 1,024 characters and malformed ASN.1 streams in input files can lead to a stack-based buffer overflow. This may allow remote code execution. CVE-2017-11497 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). Malformed ASN.1 streams in V2C and similar input files can be used to generate stack-based buffer overflows. This could allow remote code execution. CVE-2017-11496 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). XML payload with more than supported number of elements leads to buffer overflow of a variable in stack. This vulnerability can be exploited for denial of service. CVE-2017-12818 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H). XML payload with more than supported number of elements leads to buffer overflow of a variable in stack. This vulnerability can be exploited for denial of service or arbitrary code execution. CVE-2017-12821 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). Malformed HTTP request body in Admin APIs can be used to generate heap buffer overflows. This vulnerability can be exploited for denial of service. CVE-2017-12820 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H). License manager web interface is enabled as a default configuration, and even if disabled, it can be re-enabled remotely. This vulnerability can be exploited to perform above mentioned attacks remotely. CVE-2017-12822 has been assigned to this vulnerability. A CVSS v3 base score of 9.9 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:L/A:L).
[]
null
null
9.9
null