Spaces:
Runtime error
Runtime error
SUBMIT_TEXT = f""" | |
# Evaluation Queue for the π€"Powered by Intel" LLM Leaderboard π» | |
Models added here will be queued for evaluation on the Intel Developer Cloud βοΈ | |
## First steps before submitting a model | |
### 1) Make sure you can load your model and tokenizer using AutoClasses: | |
```python | |
from transformers import AutoConfig, AutoModel, AutoTokenizer | |
config = AutoConfig.from_pretrained("your model name", revision=revision) | |
model = AutoModel.from_pretrained("your model name", revision=revision) | |
tokenizer = AutoTokenizer.from_pretrained("your model name", revision=revision) | |
``` | |
If this step fails, follow the error messages to debug your model before submitting it. It's likely your model has been improperly uploaded. | |
Note: make sure your model is public! | |
Note: if your model needs `use_remote_code=True`, we do not support this option yet but we are working on adding it, stay posted! | |
### 2) Convert your model weights to [safetensors](https://huggingface.co/docs/safetensors/index) | |
It's a new format for storing weights which is safer and faster to load and use. It will also allow us to add the number of parameters of your model to the `Extended Viewer`! | |
### 3) Make sure your model has an open license! | |
This is a leaderboard for Open LLMs, and we'd love for as many people as possible to know they can use your model π€ | |
### 4) Fill up your model card | |
We use your model card to better understand the properties of your model and make them more easily discoverable for other users. | |
Model cards are required to have mentions of the hardware, software, and infrastructure used for training - without this information | |
we cannot accept your model as a valid submission. | |
### 5) Select the correct precision | |
Not all models are converted properly from `float16` to `bfloat16`, and selecting the wrong precision can sometimes cause evaluation error (as loading a `bf16` model in `fp16` can sometimes generate NaNs, depending on the weight range). | |
## In case of model failure | |
If your model is displayed in the `FAILED` category, its execution stopped. | |
Make sure you have followed the above steps first. | |
If everything is done, check you can launch the EleutherAIHarness on your model locally, using the command in the About tab under "Reproducibility" with all arguments specified (you can add `--limit` to limit the number of examples per task). | |
""" |