Spaces:
Running
Running
| /** | |
| * @license | |
| * Copyright 2015 The Emscripten Authors | |
| * SPDX-License-Identifier: MIT | |
| */ | |
| // Pthread Web Worker startup routine: | |
| // This is the entry point file that is loaded first by each Web Worker | |
| // that executes pthreads on the Emscripten application. | |
| ; | |
| var Module = {}; | |
| // Thread-local guard variable for one-time init of the JS state | |
| var initializedJS = false; | |
| // Proxying queues that were notified before the thread started and need to be | |
| // executed as part of startup. | |
| var pendingNotifiedProxyingQueues = []; | |
| function assert(condition, text) { | |
| if (!condition) abort('Assertion failed: ' + text); | |
| } | |
| function threadPrintErr() { | |
| var text = Array.prototype.slice.call(arguments).join(' '); | |
| console.error(text); | |
| } | |
| function threadAlert() { | |
| var text = Array.prototype.slice.call(arguments).join(' '); | |
| postMessage({cmd: 'alert', text: text, threadId: Module['_pthread_self']()}); | |
| } | |
| // We don't need out() for now, but may need to add it if we want to use it | |
| // here. Or, if this code all moves into the main JS, that problem will go | |
| // away. (For now, adding it here increases code size for no benefit.) | |
| var out = () => { throw 'out() is not defined in worker.js.'; } | |
| var err = threadPrintErr; | |
| self.alert = threadAlert; | |
| Module['instantiateWasm'] = (info, receiveInstance) => { | |
| // Instantiate from the module posted from the main thread. | |
| // We can just use sync instantiation in the worker. | |
| var instance = new WebAssembly.Instance(Module['wasmModule'], info); | |
| receiveInstance(instance, Module['wasmModule']); | |
| // We don't need the module anymore; new threads will be spawned from the main thread. | |
| Module['wasmModule'] = null; | |
| return instance.exports; | |
| } | |
| self.onmessage = (e) => { | |
| try { | |
| if (e.data.cmd === 'load') { // Preload command that is called once per worker to parse and load the Emscripten code. | |
| // Module and memory were sent from main thread | |
| Module['wasmModule'] = e.data.wasmModule; | |
| Module['dynamicLibraries'] = e.data.dynamicLibraries; | |
| Module['wasmMemory'] = e.data.wasmMemory; | |
| Module['buffer'] = Module['wasmMemory'].buffer; | |
| Module['ENVIRONMENT_IS_PTHREAD'] = true; | |
| if (typeof e.data.urlOrBlob == 'string') { | |
| importScripts(e.data.urlOrBlob); | |
| } else { | |
| var objectUrl = URL.createObjectURL(e.data.urlOrBlob); | |
| importScripts(objectUrl); | |
| URL.revokeObjectURL(objectUrl); | |
| } | |
| Godot(Module).then(function (instance) { | |
| Module = instance; | |
| }); | |
| } else if (e.data.cmd === 'run') { | |
| // This worker was idle, and now should start executing its pthread entry | |
| // point. | |
| // performance.now() is specced to return a wallclock time in msecs since | |
| // that Web Worker/main thread launched. However for pthreads this can | |
| // cause subtle problems in emscripten_get_now() as this essentially | |
| // would measure time from pthread_create(), meaning that the clocks | |
| // between each threads would be wildly out of sync. Therefore sync all | |
| // pthreads to the clock on the main browser thread, so that different | |
| // threads see a somewhat coherent clock across each of them | |
| // (+/- 0.1msecs in testing). | |
| Module['__performance_now_clock_drift'] = performance.now() - e.data.time; | |
| // Pass the thread address to wasm to store it for fast access. | |
| Module['__emscripten_thread_init'](e.data.pthread_ptr, /*isMainBrowserThread=*/0, /*isMainRuntimeThread=*/0, /*canBlock=*/1); | |
| assert(e.data.pthread_ptr); | |
| // Also call inside JS module to set up the stack frame for this pthread in JS module scope | |
| Module['establishStackSpace'](); | |
| Module['PThread'].receiveObjectTransfer(e.data); | |
| Module['PThread'].threadInitTLS(); | |
| if (!initializedJS) { | |
| // Execute any proxied work that came in before the thread was | |
| // initialized. Only do this once because it is only possible for | |
| // proxying notifications to arrive before thread initialization on | |
| // fresh workers. | |
| pendingNotifiedProxyingQueues.forEach(queue => { | |
| Module['executeNotifiedProxyingQueue'](queue); | |
| }); | |
| pendingNotifiedProxyingQueues = []; | |
| initializedJS = true; | |
| } | |
| try { | |
| Module['invokeEntryPoint'](e.data.start_routine, e.data.arg); | |
| } catch(ex) { | |
| if (ex != 'unwind') { | |
| // ExitStatus not present in MINIMAL_RUNTIME | |
| if (ex instanceof Module['ExitStatus']) { | |
| if (Module['keepRuntimeAlive']()) { | |
| err('Pthread 0x' + Module['_pthread_self']().toString(16) + ' called exit(), staying alive due to noExitRuntime.'); | |
| } else { | |
| err('Pthread 0x' + Module['_pthread_self']().toString(16) + ' called exit(), calling _emscripten_thread_exit.'); | |
| Module['__emscripten_thread_exit'](ex.status); | |
| } | |
| } | |
| else | |
| { | |
| // The pthread "crashed". Do not call `_emscripten_thread_exit` (which | |
| // would make this thread joinable. Instead, re-throw the exception | |
| // and let the top level handler propagate it back to the main thread. | |
| throw ex; | |
| } | |
| } else { | |
| // else e == 'unwind', and we should fall through here and keep the pthread alive for asynchronous events. | |
| err('Pthread 0x' + Module['_pthread_self']().toString(16) + ' completed its main entry point with an `unwind`, keeping the worker alive for asynchronous operation.'); | |
| } | |
| } | |
| } else if (e.data.cmd === 'cancel') { // Main thread is asking for a pthread_cancel() on this thread. | |
| if (Module['_pthread_self']()) { | |
| Module['__emscripten_thread_exit'](-1/*PTHREAD_CANCELED*/); | |
| } | |
| } else if (e.data.target === 'setimmediate') { | |
| // no-op | |
| } else if (e.data.cmd === 'processProxyingQueue') { | |
| if (initializedJS) { | |
| Module['executeNotifiedProxyingQueue'](e.data.queue); | |
| } else { | |
| // Defer executing this queue until the runtime is initialized. | |
| pendingNotifiedProxyingQueues.push(e.data.queue); | |
| } | |
| } else { | |
| err('worker.js received unknown command ' + e.data.cmd); | |
| err(e.data); | |
| } | |
| } catch(ex) { | |
| err('worker.js onmessage() captured an uncaught exception: ' + ex); | |
| if (ex && ex.stack) err(ex.stack); | |
| if (Module['__emscripten_thread_crashed']) { | |
| Module['__emscripten_thread_crashed'](); | |
| } | |
| throw ex; | |
| } | |
| }; | |