@@ -16,14 +16,14 @@ Last checked and validated with fastMONAI version 0.3.2. Please ensure that you
|
|
16 |
|
17 |

|
18 |
|
19 |
-
## Data
|
20 |
|
21 |
### Origin of MRI Scans
|
22 |
- **Haukeland University Hospital (HUH)**: 15 T2-weighted MRI scans
|
23 |
- **Sahlgren-ska University Hospital (SUH)**: 10 T2-weighted MRI scans
|
24 |
|
25 |
-
### HUH
|
26 |
-
-
|
27 |
#### Scanner Specifications
|
28 |
- Type: Siemens MAGNETOM Avanto 1.5 T
|
29 |
- Slice Thickness: 4 mm
|
@@ -34,8 +34,8 @@ Last checked and validated with fastMONAI version 0.3.2. Please ensure that you
|
|
34 |
- Echo Time: 87 ms
|
35 |
- Number of Acquisitions: 2
|
36 |
|
37 |
-
### SUH
|
38 |
-
- [
|
39 |
#### Scanner Specifications
|
40 |
- Type: Siemens MAGNETOM Aera 1.5 T
|
41 |
- Slice Thickness: 3.5 mm
|
@@ -46,14 +46,13 @@ Last checked and validated with fastMONAI version 0.3.2. Please ensure that you
|
|
46 |
- Echo Time: 95 ms
|
47 |
- Number of Acquisitions: 1
|
48 |
|
49 |
-
|
50 |
-
|
51 |
- **Process**: Manual segmentation of vertebrae
|
52 |
- **Experts**: Conducted by an MRI expert with consensus from a senior radiologist
|
53 |
- **Software**: ITK-SNAP
|
54 |
- **Scope**: Segmented vertebrae in all slices, including bone marrow but excluding vertebral cortex
|
55 |
|
56 |
-
|
57 |
|
58 |
- **Source**: [Annotated T2-weighted MR images of the Lower Spine](https://zenodo.org/record/22304)
|
59 |
- **Scan Specifications**: 23 scans, 1.5 T in sagittal orientation
|
|
|
16 |
|
17 |

|
18 |
|
19 |
+
## Data
|
20 |
|
21 |
### Origin of MRI Scans
|
22 |
- **Haukeland University Hospital (HUH)**: 15 T2-weighted MRI scans
|
23 |
- **Sahlgren-ska University Hospital (SUH)**: 10 T2-weighted MRI scans
|
24 |
|
25 |
+
### Haukeland University Hospital (HUH): 15 T2-weighted MRI scans
|
26 |
+
- [Study](https://trialsjournal.biomedcentral.com/articles/10.1186/s13063-017-2306-8)
|
27 |
#### Scanner Specifications
|
28 |
- Type: Siemens MAGNETOM Avanto 1.5 T
|
29 |
- Slice Thickness: 4 mm
|
|
|
34 |
- Echo Time: 87 ms
|
35 |
- Number of Acquisitions: 2
|
36 |
|
37 |
+
### Sahlgren-ska University Hospital (SUH): 10 T2-weighted MRI scans
|
38 |
+
- [Study](https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5789539/)
|
39 |
#### Scanner Specifications
|
40 |
- Type: Siemens MAGNETOM Aera 1.5 T
|
41 |
- Slice Thickness: 3.5 mm
|
|
|
46 |
- Echo Time: 95 ms
|
47 |
- Number of Acquisitions: 1
|
48 |
|
49 |
+
### Data Annotation
|
|
|
50 |
- **Process**: Manual segmentation of vertebrae
|
51 |
- **Experts**: Conducted by an MRI expert with consensus from a senior radiologist
|
52 |
- **Software**: ITK-SNAP
|
53 |
- **Scope**: Segmented vertebrae in all slices, including bone marrow but excluding vertebral cortex
|
54 |
|
55 |
+
### External Data Evaluation
|
56 |
|
57 |
- **Source**: [Annotated T2-weighted MR images of the Lower Spine](https://zenodo.org/record/22304)
|
58 |